Use of nickel implanted boron-doped diamond thin film electrode coupled to HPLC system for the determination of tetracyclines

被引:32
作者
Treetepvijit, S
Preechaworapun, A
Praphairaksit, N
Chuanuwatanakul, U
Einaga, Y
Chailapakul, O [1 ]
机构
[1] Chulalongkorn Univ, Fac Sci, Dept Chem, Mat Chem & Catalysis Res Unit, Bangkok 10330, Thailand
[2] Keio Univ, Fac Sci & Technol, Dept Chem, Yokohama, Kanagawa 2238522, Japan
关键词
tetracyclines; nickel-implanted boron-doped diamond; cyclic voltarnmetry; flow injection system; HPLC; amperometric detection;
D O I
10.1016/j.talanta.2005.07.047
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrochemical analysis of tetracyclines was investigated using nickel-implanted boron-doped diamond thin film electrode (Ni-DIA) by cyclic voltammetry and high performance liquid chromatographic with amperometry. Cyclic voltammetry was used to study the electrochemical oxidation of tetracyclines. Comparison experiments were carried out utilizing as-deposited BDD and glassy carbon electrodes. Ni-DIA electrode provided well-resolved oxidative irreversible cyclic voltammograms and the highest current signals among the electrode studied. High performance liquid chromatography (HPLC) with amperometric detection was also studied. The chromatography was performed using a commercially available Inertsil C18 column, with the mobile phase being: 80% phosphate buffer (pH 2.5)-20% acetonitrile and detected at 1.55 V. The methods were validated over the concentration range 0.05-100 ppm with the overall average recoveries from 83.3 to 102.5% and R.S.D. of less than 10%. The proposed method was further applied to analyse shrimp samples. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:1329 / 1335
页数:7
相关论文
共 35 条
[1]   Confirmation of multiple tetracycline residues in milk and oxytetracycline in shrimp by liquid chromatography particle beam mass spectrometry [J].
Carson, MC ;
Ngoh, MA ;
Hadley, SW .
JOURNAL OF CHROMATOGRAPHY B, 1998, 712 (1-2) :113-128
[2]   STUDY OF A NICKEL-CATALYZED GLASSY-CARBON ELECTRODE FOR DETECTION OF CARBOHYDRATES IN LIQUID-CHROMATOGRAPHY AND FLOW-INJECTION ANALYSIS [J].
CASELLA, IG ;
DEIMONI, F ;
CATALDI, TRI .
ANALYTICA CHIMICA ACTA, 1991, 248 (01) :117-125
[3]   ELECTROCATALYTIC OXIDATION AND LIQUID-CHROMATOGRAPHIC DETECTION OF ALIPHATIC-ALCOHOLS AT A NICKEL-BASED GLASSY-CARBON MODIFIED ELECTRODE [J].
CASELLA, IG ;
CATALDI, TRI ;
SALVI, AM ;
DESIMONI, E .
ANALYTICAL CHEMISTRY, 1993, 65 (21) :3143-3150
[4]  
CASELLA IG, 1991, ANAL CHIM ACTA, V243, P61, DOI [10.1016/S0003-2670(00)82540-4, 10.1016/S0003-2670(00)82541-6]
[5]   COBALT-BASED GLASSY-CARBON CHEMICALLY MODIFIED ELECTRODE FOR CONSTANT-POTENTIAL AMPEROMETRIC DETECTION OF CARBOHYDRATES IN FLOW-INJECTION ANALYSIS AND LIQUID-CHROMATOGRAPHY [J].
CATALDI, TRI ;
CASELLA, IG ;
DESIMONI, E ;
ROTUNNO, T .
ANALYTICA CHIMICA ACTA, 1992, 270 (01) :161-171
[6]   The electrooxidation of sulfur-containing compounds at boron-doped diamond electrode [J].
Chailapakul, O ;
Aksharanandana, P ;
Frelink, T ;
Einaga, Y ;
Fujishima, A .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 80 (03) :193-201
[7]   Analysis of tetracycline antibiotics using HPLC with pulsed amperometric detection [J].
Charoenraks, T ;
Chuanuwatanakul, S ;
Honda, K ;
Yamaguchi, Y ;
Chailapakul, O .
ANALYTICAL SCIENCES, 2005, 21 (03) :241-245
[8]   Quantitative multi-residue analysis of tetracyclines and their 4-epimers in pig tissues by high-performance liquid chromatography combined with positive-ion electrospray ionization mass spectrometry [J].
Cherlet, M ;
Schelkens, M ;
Croubels, S ;
De Backer, P .
ANALYTICA CHIMICA ACTA, 2003, 492 (1-2) :199-213
[9]   Improved method for the on-line metal chelate affinity chromatography high-performance liquid chromatographic determination of tetracycline antibiotics in animal products [J].
Cooper, AD ;
Stubbings, GWF ;
Kelly, M ;
Tarbin, JA ;
Farrington, WHH ;
Shearer, G .
JOURNAL OF CHROMATOGRAPHY A, 1998, 812 (1-2) :321-326
[10]   Tetracycline, oxytetracycline and chlortetracycline determination by flow injection potentiometry [J].
Couto, CMCM ;
Lima, JLFC ;
Conceiçao, M ;
Montenegro, BSM ;
Reis, S .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 18 (4-5) :527-533