Electrochemical sensing with electrodes modified with molecularly imprinted polymer films

被引:106
作者
Blanco-López, MC [1 ]
Gutiérrez-Fernández, S [1 ]
Lobo-Castañón, MJ [1 ]
Miranda-Ordieres, AJ [1 ]
Tuñón-Blanco, P [1 ]
机构
[1] Univ Oviedo, Fac Quim, Dept Quim Fis & Analit, E-33006 Oviedo, Spain
关键词
molecularly imprinted polymers; voltammetric sensors; biomimetics;
D O I
10.1007/s00216-003-2330-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This article summarises our work on the development of voltammetric sensors based on molecularly imprinted polymers. Several recognition elements and integration strategies were used: 1.membranes electropolymerised at the electrode surface; 2.casting of polymeric membranes by drop-coating a solution of pre-formed polymer (polyphosphazene) and template in a low-boiling-point solvent on to the electrode surface; 3.preparation of composite membranes containing conductive material (graphite or carbon black), acrylic-type molecularly imprinted polymers (small particle size), and PVC as binder; and 4.in-situ polymerisation of a thin layer of acrylic imprinted polymer deposited on the electrode surface by spin coating. All the options evaluated offer the possibility of controlling electrode characteristics such as hydrophobic/hydrophilic character, permeability, or film thickness, which are essential for obtaining good sensor performance.
引用
收藏
页码:1922 / 1928
页数:7
相关论文
共 37 条
[31]   Molecularly imprinted microparticles for capillary electrochromatographic enantiomer separation of propranolol [J].
Schweitz, L ;
Spégel, P ;
Nilsson, S .
ANALYST, 2000, 125 (11) :1899-1901
[32]   Investigation into the scope and limitations of molecular imprinting with DNA molecules [J].
Spivak, DA ;
Shea, KJ .
ANALYTICA CHIMICA ACTA, 2001, 435 (01) :65-74
[33]   Selectivity and sensitivity of ultrathin purine-templated overoxidized polypyrrole film electrodes [J].
Spurlock, LD ;
Jaramillo, A ;
Praserthdam, A ;
Lewis, J ;
BrajterToth, A .
ANALYTICA CHIMICA ACTA, 1996, 336 (1-3) :37-46
[34]   A piezoelectric biomimetic sensor for aminopyrine with a molecularly imprinted polymer coating [J].
Tan, YG ;
Nie, LH ;
Yao, SZ .
ANALYST, 2001, 126 (05) :664-668
[35]   A study of a bio-mimetic recognition material for the BAW sensor by molecular imprinting and its application for the determination of paracetamol in the human serum and urine [J].
Tan, YG ;
Zhou, ZL ;
Wang, P ;
Nie, LH ;
Yao, SZ .
TALANTA, 2001, 55 (02) :337-347
[36]   Molecular imprint membranes prepared by the phase inversion precipitation technique [J].
Wang, HY ;
Kobayashi, T ;
Fujii, N .
LANGMUIR, 1996, 12 (20) :4850-4856
[37]   Molecular imprint membranes prepared by the phase inversion precipitation technique .2. Influence of coagulation temperature in the phase inversion process on the encoding in polymeric membranes [J].
Wang, HY ;
Kobayashi, T ;
Fukaya, T ;
Fujii, N .
LANGMUIR, 1997, 13 (20) :5396-5400