共 21 条
A method for coronary artery calcium scoring using contrast-enhanced computed tomography
被引:42
作者:
Otton, James M.
[1
,2
]
Lonborg, Jacob T.
[3
]
Boshell, David
[1
]
Feneley, Michael
[1
,2
]
Hayen, Andrew
[4
]
Sammel, Neville
[1
]
Sesel, Ken
[1
]
Bester, Lourens
[1
,2
]
McCrohon, Jane
[1
,2
]
机构:
[1] St Vincents Hosp, Dept Cardiol, Darlinghurst, NSW 2010, Australia
[2] Univ New S Wales, Sydney, NSW 2052, Australia
[3] Rigshosp, DK-2100 Copenhagen, Denmark
[4] Univ Sydney, Screening & Test Evaluat Program, Sch Publ Hlth, Sydney, NSW 2006, Australia
基金:
英国医学研究理事会;
关键词:
Cardiac computed tomography;
Coronary CT angiography;
Calcium artery calcium score;
MULTIDETECTOR ROW CT;
CARDIAC CT;
IN-VITRO;
QUANTIFICATION;
ANGIOGRAPHY;
RISK;
ATHEROSCLEROSIS;
PREDICTION;
AGREEMENT;
ACCURACY;
D O I:
10.1016/j.jcct.2011.11.004
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
BACKGROUND: Limitations to the coronary calcium score include its requirement for noncontrast imaging and radiation exposure that approaches current methods for contrast-enhanced CT angiography. OBJECTIVES: We sought to derive and validate a method of measuring the coronary artery calcium score (CACS) from standard contrast-enhanced CT, obviating the need for a second non-contrast calcium scan. METHODS: The volume of intramural calcium of >320 HU in major coronary vessels was measured in 90 contrast-enhanced and traditional non-contrast calcium scan pairs. An empiric conversion factor was derived to convert the small voxel contrast-enhanced calcium volume to an Agatston calcium score. The accuracy of this technique was then prospectively validated in 120 consecutive patients undergoing clinical calcium scans and contrasted-enhanced coronary CT. Eleven patients were excluded from analysis because of the prespecified criteria of excessive noise in the contrast-enhanced CT or total coronary artery occlusion. RESULTS: The Pearson correlation of the contrast scan-derived calcium score with the measured CACS was r(2) = 0.99. With standard CACS risk bands, agreement of the contrast-enhanced calcium score estimate with the measured CAC by quadratic weighted kappa was 0.96. The 95% limits of agreement (Agatston units) were given by +/-(3.2+0.14 x CACS +4.44 root CACS). Inter-observer and intra-observer reliability with the intraclass correlation was 0.99. CONCLUSION: The calcium score can be accurately measured from contrast-enhanced cardiac CT scans with the use of a Hounsfield unit threshold of 320. (C) 2012 Published by Elsevier Inc. on behalf of Society of Cardiovascular Computed Tomography.
引用
收藏
页码:37 / 44
页数:8
相关论文