A method for coronary artery calcium scoring using contrast-enhanced computed tomography

被引:42
作者
Otton, James M. [1 ,2 ]
Lonborg, Jacob T. [3 ]
Boshell, David [1 ]
Feneley, Michael [1 ,2 ]
Hayen, Andrew [4 ]
Sammel, Neville [1 ]
Sesel, Ken [1 ]
Bester, Lourens [1 ,2 ]
McCrohon, Jane [1 ,2 ]
机构
[1] St Vincents Hosp, Dept Cardiol, Darlinghurst, NSW 2010, Australia
[2] Univ New S Wales, Sydney, NSW 2052, Australia
[3] Rigshosp, DK-2100 Copenhagen, Denmark
[4] Univ Sydney, Screening & Test Evaluat Program, Sch Publ Hlth, Sydney, NSW 2006, Australia
基金
英国医学研究理事会;
关键词
Cardiac computed tomography; Coronary CT angiography; Calcium artery calcium score; MULTIDETECTOR ROW CT; CARDIAC CT; IN-VITRO; QUANTIFICATION; ANGIOGRAPHY; RISK; ATHEROSCLEROSIS; PREDICTION; AGREEMENT; ACCURACY;
D O I
10.1016/j.jcct.2011.11.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Limitations to the coronary calcium score include its requirement for noncontrast imaging and radiation exposure that approaches current methods for contrast-enhanced CT angiography. OBJECTIVES: We sought to derive and validate a method of measuring the coronary artery calcium score (CACS) from standard contrast-enhanced CT, obviating the need for a second non-contrast calcium scan. METHODS: The volume of intramural calcium of >320 HU in major coronary vessels was measured in 90 contrast-enhanced and traditional non-contrast calcium scan pairs. An empiric conversion factor was derived to convert the small voxel contrast-enhanced calcium volume to an Agatston calcium score. The accuracy of this technique was then prospectively validated in 120 consecutive patients undergoing clinical calcium scans and contrasted-enhanced coronary CT. Eleven patients were excluded from analysis because of the prespecified criteria of excessive noise in the contrast-enhanced CT or total coronary artery occlusion. RESULTS: The Pearson correlation of the contrast scan-derived calcium score with the measured CACS was r(2) = 0.99. With standard CACS risk bands, agreement of the contrast-enhanced calcium score estimate with the measured CAC by quadratic weighted kappa was 0.96. The 95% limits of agreement (Agatston units) were given by +/-(3.2+0.14 x CACS +4.44 root CACS). Inter-observer and intra-observer reliability with the intraclass correlation was 0.99. CONCLUSION: The calcium score can be accurately measured from contrast-enhanced cardiac CT scans with the use of a Hounsfield unit threshold of 320. (C) 2012 Published by Elsevier Inc. on behalf of Society of Cardiovascular Computed Tomography.
引用
收藏
页码:37 / 44
页数:8
相关论文
共 21 条
[11]   Coronary artery calcium: Accuracy and reproducibility of measurements with multi-detector row CT - Assessment of effects of different thresholds and quantification methods [J].
Hong, C ;
Bae, KT ;
Pilgram, TK .
RADIOLOGY, 2003, 227 (03) :795-801
[12]   Coronary artery calcium: Absolute quantification in nonenhanced and contrast-enhanced multi-detector row CT studies [J].
Hong, C ;
Becker, CR ;
Schoepf, UJ ;
Ohnesorge, B ;
Bruening, R ;
Reiser, MF .
RADIOLOGY, 2002, 223 (02) :474-480
[13]   Coronary Artery Calcification Screening Estimated Radiation Dose and Cancer Risk [J].
Kim, Kwang Pyo ;
Einstein, Andrew J. ;
de Gonzalez, Amy Berrington .
ARCHIVES OF INTERNAL MEDICINE, 2009, 169 (13) :1188-1194
[14]   MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (01) :159-174
[15]  
Mühlenbruch G, 2005, INVEST RADIOL, V40, P148
[16]  
Mühlenbruch G, 2005, INVEST RADIOL, V40, P695
[17]   Coronary Artery Calcium Score and Risk Classification for Coronary Heart Disease Prediction [J].
Polonsky, Tamar S. ;
McClelland, Robyn L. ;
Jorgensen, Neal W. ;
Bild, Diane E. ;
Burke, Gregory L. ;
Guerci, Alan D. ;
Greenland, Philip .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2010, 303 (16) :1610-1616
[18]   Electron beam computed tomographic coronary calcium scanning: A review and guidelines for use in asymptomatic persons [J].
Rumberger, JA ;
Brundage, BH ;
Rader, DJ ;
Kondos, G .
MAYO CLINIC PROCEEDINGS, 1999, 74 (03) :243-252
[19]   Serial electron beam CT measurements of coronary artery calcium: Has your patient's calcium score actually changed? [J].
Sevrukov, AB ;
Bland, JM ;
Kondos, GT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (06) :1546-1553
[20]   Identification and quantification of coronary atherosclerotic plaques: A comparison of 64-MDCT and intravascular ultrasound [J].
Sun, Junyan ;
Zhang, Zhaoqi ;
Lu, Biao ;
Yu, Wei ;
Yang, Ya ;
Zhou, Yujie ;
Wang, Yanhui ;
Fan, Zhanming .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (03) :748-754