Materials for Diabetes Therapeutics

被引:138
作者
Bratlie, Kaitlin M. [1 ,2 ,3 ]
York, Roger L. [1 ,2 ]
Invernale, Michael A. [1 ,2 ]
Langer, Robert [1 ,2 ,3 ,4 ]
Anderson, Daniel G. [1 ,2 ,3 ,4 ]
机构
[1] MIT, Koch Inst Integrat Canc Res, Cambridge, MA 02142 USA
[2] Childrens Hosp, Dept Anesthesiol, Boston, MA 02115 USA
[3] MIT, Dept Chem Engn, Cambridge, MA 02139 USA
[4] MIT, Harvard Mit Div Hlth Sci & Technol, Cambridge, MA 02142 USA
基金
美国国家卫生研究院;
关键词
RESPONSIVE POLYMER GEL; LOOP INSULIN DELIVERY; ELECTROCHEMICAL GLUCOSE SENSORS; CRITICAL SOLUTION TEMPERATURE; TRANSDERMAL DRUG-DELIVERY; CONTROLLED-RELEASE; POLY(VINYL ALCOHOL); IN-VITRO; CELL ENCAPSULATION; SUSTAINED-RELEASE;
D O I
10.1002/adhm.201200037
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
This review is focused on the materials and methods used to fabricate closed-loop systems for type 1 diabetes therapy. Herein, we give a brief overview of current methods used for patient care and discuss two types of possible treatments and the materials used for these therapies-(i) artificial pancreases, comprised of insulin producing cells embedded in a polymeric biomaterial, and (ii) totally synthetic pancreases formulated by integrating continuous glucose monitors with controlled insulin release through degradable polymers and glucose-responsive polymer systems. Both the artificial and the completely synthetic pancreas have two major design requirements: the device must be both biocompatible and be permeable to small molecules and proteins, such as insulin. Several polymers and fabrication methods of artificial pancreases are discussed: microencapsulation, conformal coatings, and planar sheets. We also review the two components of a completely synthetic pancreas. Several types of glucose sensing systems (including materials used for electrochemical, optical, and chemical sensing platforms) are discussed, in addition to various polymer-based release systems (including ethylene-vinyl acetate, polyanhydrides, and phenylboronic acid containing hydrogels).
引用
收藏
页码:267 / 284
页数:18
相关论文
共 182 条
[1]
Chitosan microcapsules as controlled release systems for insulin [J].
Aiedeh, K ;
Gianasi, E ;
Orienti, I ;
Zecchi, V .
JOURNAL OF MICROENCAPSULATION, 1997, 14 (05) :567-576
[2]
[Anonymous], 2012, DIAB STAT
[3]
[Anonymous], 2010, ROBBINS COTRAN PATHO
[4]
Ansari AA, 2010, BIOSENSORS, P23
[5]
Glucose-sensitive lower critical solution temperature changes of copolymers composed of N-isopropylacrylamide and phenylboronic acid moieties [J].
Aoki, T ;
Nagao, Y ;
Sanui, K ;
Ogata, N ;
Kikuchi, A ;
Sakurai, Y ;
Kataoka, K ;
Okano, T .
POLYMER JOURNAL, 1996, 28 (04) :371-374
[6]
Electrochemical characteristics of glucose oxidase immobilized in poly(quinone) redox polymers [J].
Arai, G ;
Shoji, K ;
Yasumori, I .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2006, 591 (01) :1-6
[7]
Accurate Spectroscopic Calibration for Noninvasive Glucose Monitoring by Modeling the Physiological Glucose Dynamics [J].
Barman, Ishan ;
Kong, Chae-Ryon ;
Singh, Gajendra P. ;
Dasari, Ramachandra R. ;
Feld, Michael S. .
ANALYTICAL CHEMISTRY, 2010, 82 (14) :6104-6114
[8]
Reversible control of carbon nanotube aggregation for a glucose affinity sensor [J].
Barone, Paul W. ;
Strano, Michael S. .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2006, 45 (48) :8138-8141
[9]
Near-infrared optical sensors based on single-walled carbon nanotubes [J].
Barone, PW ;
Baik, S ;
Heller, DA ;
Strano, MS .
NATURE MATERIALS, 2005, 4 (01) :86-U16
[10]
Stabilization of wired glucose oxidase anodes rotating at 1000 rpm at 37°C [J].
Binyamin, G ;
Heller, A .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1999, 146 (08) :2965-2967