High resolution mechanical function in the intact porcine heart: mechanical effects of pacemaker location

被引:6
作者
Azeloglu, EU
Yun, YH
Saltman, AE
Krukenkamp, IB
Chiang, FP
Chen, WL
Gaudette, GR
机构
[1] Univ Massachusetts, Dept Surg, Div Cardiothorac Surg, Worcester, MA 01655 USA
[2] SUNY Stony Brook, Dept Biomed Engn, Stony Brook, NY 11794 USA
[3] Columbia Univ, Dept Biomed Engn, New York, NY 10027 USA
[4] Univ Akron, Dept Biomed Engn, Akron, OH 44325 USA
[5] SUNY Stony Brook, Div Cardiothorac Surg, Stony Brook, NY 11794 USA
[6] SUNY Stony Brook, Inst Mol Cardiol, Stony Brook, NY 11794 USA
[7] SUNY Stony Brook, Dept Mech Engn, Stony Brook, NY 11794 USA
关键词
ventricular function; mapping; conduction;
D O I
10.1016/j.jbiomech.2004.12.018
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The necessity to quantify the mechanical function with high spatial resolution stemmed from the advancement of myocardial salvaging techniques. Since these therapies are localized interventions, a whole field technique with high spatial resolution was needed to differentiate the normal, diseased, and treated myocardium. We developed a phase correlation algorithm for measuring myocardial displacement at high spatial resolution and to determine the regional mechanical function in the intact heart. Porcine hearts were exposed and high contrast microparticles were placed on the myocardium. A pressure transducer, inserted into the left ventricle, synchronized the pressure (LVP) with image acquisition using a charge-coupled device camera. The deformation of the myocardium was measured with a resolution of 0.58 +/- 0.04mm. Within the region of interest (ROI), regional stroke work (RSW), defined as the integral of LVP with respect to regional area, was determined on average at 21 locations with a resolution of 27.1 +/- 2.7mm(2). To alter regional mechanical function, the heart was paced at three different locations around the ROI. Independent of the pacemaker location, RSW decreased in the ROI. In addition, a gradient of increasing RSW in the outward direction radiating from the pacemaker was observed in all pacing protocols. These data demonstrated the ability to determine regional whole field mechanical function with high spatial resolution, and the significant alterations induced by electrical pacing. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:717 / 725
页数:9
相关论文
共 20 条
[1]   ANGIOGENIC-INDUCED ENHANCEMENT OF COLLATERAL BLOOD-FLOW TO ISCHEMIC MYOCARDIUM BY VASCULAR ENDOTHELIAL GROWTH-FACTOR IN DOGS [J].
BANAI, S ;
JAKLITSCH, MT ;
SHOU, M ;
LAZAROUS, DF ;
SCHEINOWITZ, M ;
BIRO, S ;
EPSTEIN, SE ;
UNGER, EF .
CIRCULATION, 1994, 89 (05) :2183-2189
[2]   Multisite pacing for end-stage heart failure: Early experience [J].
Cazeau, S ;
Ritter, P ;
Lazarus, A ;
Gras, D ;
Backdach, H ;
Mundler, O ;
Mugica, J .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (11) :1748-1757
[3]   DIGITAL SPECKLE-DISPLACEMENT MEASUREMENT USING A COMPLEX SPECTRUM METHOD [J].
CHEN, DJ ;
CHIANG, FP ;
TAN, YS ;
DON, HS .
APPLIED OPTICS, 1993, 32 (11) :1839-1849
[4]   Epicardial left ventricular lead placement for cardiac resynchronization therapy: Optimal pace site selection with pressure-volume loops [J].
Dekker, ALAJ ;
Phelps, B ;
Dijkman, B ;
van Der Nagel, T ;
van Der Veen, FH ;
Geskes, GG ;
Maessen, JG .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2004, 127 (06) :1641-1647
[5]   RELATION BETWEEN REGIONAL ELECTRICAL ACTIVATION TIME AND SUBEPICARDIAL FIBER STRAIN IN THE CANINE LEFT-VENTRICLE [J].
DELHAAS, T ;
ARTS, T ;
PRINZEN, FW ;
RENEMAN, RS .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1993, 423 (1-2) :78-87
[6]   Angiogenic therapy of the human heart [J].
Folkman, J .
CIRCULATION, 1998, 97 (07) :628-629
[7]  
Gaudette G. R., 2002, CARDIOVASC ENG, V2, P129
[8]   Effects of ischemia on epicardial deformation in the passive rabbit heart [J].
Gaudette, GR ;
Krukenkamp, IB ;
Azeloglu, EU ;
Saltman, AE ;
Lense, M ;
Todaro, J ;
Chiang, FP .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2004, 126 (01) :70-75
[9]   Computer aided speckle interferometry: A technique for measuring deformation of the surface of the heart [J].
Gaudette, GR ;
Todaro, J ;
Krukenkamp, IB ;
Chiang, FP .
ANNALS OF BIOMEDICAL ENGINEERING, 2001, 29 (09) :775-780
[10]   Intracoronary gene transfer of fibroblast growth factor-5 increases blood flow and contractile function in an ischemic region of the heart [J].
Giordano, FJ ;
Ping, PP ;
McKirnan, MD ;
Nozaki, S ;
DeMaria, AN ;
Dillmann, WH ;
MathieuCostello, O ;
Hammond, HK .
NATURE MEDICINE, 1996, 2 (05) :534-539