Impact of interseed attenuation and tissue composition for permanent prostate implants

被引:65
作者
Carrier, JF
Beaulieu, L
Therriault-Proulx, F
Roy, R
机构
[1] CHUQ, Dept RadioOncol, Quebec City, PQ G1R 2J6, Canada
[2] CHUQ, Ctr Rech Cancerol, Quebec City, PQ G1R 2J6, Canada
[3] Univ Laval, Dept Phys Genie Phys & Opt, Quebec City, PQ G1K 7P4, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
prostate brachytherapy; dosimetry; Monte Carlo; GEANT4;
D O I
10.1118/1.2168295
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
The purpose is to evaluate the impact of interseed attenuation and prostate composition for prostate treatment plans with I-125 permanent seed implants using the Monte Carlo (MC) method. The effect of seed density (number of seeds per prostate unit volume) is specifically investigated. The study focuses on treatment plans that were generated for clinical cases. For each plan, four different dose calculation techniques are compared: TG-43 based calculation, superposition MC, full MC with water prostate, and full MC with realistic prostate tissue. The prostate tissue description is from the ICRP report 23 (W. S. Snyer, M. J. Cook, E. S. Nasset, L. R. Karkhausen, G. P. Howells, and I. H. Tipton, "Report of the task group on reference man," Technical Report 23, International Commission on Radiological Protection, 1974). According to the comparisons, the seed density has an influence on interseed attenuation. A plan with a typical low seed density (42 0.6 mCi seeds in a 26 cm(3) prostate) suffers a 1.2% drop in the CTV D-90 value due to interseed attenuation. A drop of 3.0% is calculated for a higher seed density (75 0.3 mCi seeds, same prostate). The influence of the prostate composition is similar for all seed densities and prostate sizes. The difference between MC simulations in water and MC simulations in prostate tissue is between 4.4% and 4.8% for the D-90 parameter. Overall, the effect on D-90 is ranging from 5.8% to 12.8% when comparing clinically approved TG-43 and MC simulations in prostate tissue. The impact varies from one patient to the other and depends on the prostate size and the number of seeds. This effect can reach a significant level when reporting correlations between clinical effect and deposited dose. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:595 / 604
页数:10
相关论文
共 48 条
[1]
GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]
[Anonymous], 1997, UCRL 50400
[3]
Monte Carlo dosimetric study of best industries and alpha omega Ir-192 brachytherapy seeds [J].
Ballester, F ;
Granero, D ;
Pérez-Calatayud, J ;
Casal, E ;
Puchades, V .
MEDICAL PHYSICS, 2004, 31 (12) :3298-3305
[4]
The robustness of dose distributions to displacement and migration of 125I permanent seed implants over a wide range of seed number, activity, and designs [J].
Beaulieu, L ;
Archambault, L ;
Aubin, S ;
Oral, E ;
Taschereau, R ;
Pouliot, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 58 (04) :1298-1308
[5]
Biochemical disease-free survival following I-125 prostate implantation [J].
Beyer, DC ;
Priestley, JB .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (03) :559-563
[6]
Brachytherapy dosimetry of 125I and 103Pd sources using an updated cross section library for the MCNP Monte Carlo transport code [J].
Bohm, TD ;
DeLuca, PM ;
DeWerd, LA .
MEDICAL PHYSICS, 2003, 30 (04) :701-711
[7]
Anisotropy functions for low energy interstitial brachytherapy sources:: an EGS4 Monte Carlo study [J].
Capote, R ;
Mainegra, E ;
López, E .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (01) :135-150
[8]
Validation of GEANT4, an object-oriented Monte Carlo toolkit, for simulations in medical physics [J].
Carrier, JF ;
Archambault, L ;
Beaulieu, L ;
Roy, R .
MEDICAL PHYSICS, 2004, 31 (03) :484-492
[9]
Dosimetric effects of seed anisotropy and interseed attenuation for 103Pd and 125I prostate implants [J].
Chibani, O ;
Williamson, JF ;
Todor, D .
MEDICAL PHYSICS, 2005, 32 (08) :2557-2566
[10]
Biochemical outcome after radical prostatectomy, external beam radiation therapy, or interstitial radiation therapy for clinically localized prostate cancer [J].
D'Amico, AV ;
Whittington, R ;
Malkowicz, SB ;
Schultz, D ;
Blank, K ;
Broderick, GA ;
Tomaszewski, JE ;
Renshaw, AA ;
Kaplan, I ;
Beard, CJ ;
Wein, A .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1998, 280 (11) :969-974