Feasibility of point-of-care echocardiography by internal medicine house staff

被引:108
作者
Alexander, JH
Peterson, ED
Chen, AY
Harding, TM
Adams, DB
Kisslo, JA
机构
[1] Duke Clin Res Inst, Durham, NC 27715 USA
[2] Duke Univ, Med Ctr, Durham, NC USA
关键词
D O I
10.1016/j.ahj.2003.10.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To determine whether internal medicine house staff with limited training in echocardiography can use point-of-care echocardiography to make simple, clinically important diagnoses. Background Availability of small, portable ultrasound devices could make point-of-care echocardiography widely available. The training required to perform point-of-care echocardiography has not been established. Methods Medical house staff participated in a 3-hour point-of-care echocardiography training program. Patients scheduled for standard echocardiography as part of clinical care underwent point-of-care echocardiography within 24 hours to assess four common clinically important diagnoses. Each standard echocardiogram was interpreted twice. Agreement (K) was calculated between point-of-care and standard echocardiography by using standard echocardiography as the gold standard and between the two interpretations of standard echocardiography. Results Agreement (K) between point-of-care echocardiography and standard echocardiography was 75% (0.51) for left ventricular dysfunction (ejection fraction <55%), 79% (0.31) for moderate or severe mitral regurgitation, 92% (0.32) for aortic valve thickening or immobility, and 98% (0.51) for moderate or large pericardial effusion. Agreement between the two interpretations of standard echocardiography was 83% (0.63) for left ventricular dysfunction, 92% (0.68) for moderate or severe mitral regurgitation, 95% (0.62) for aortic valve thickening or immobility, and 97% (0.53) for moderate or large pericardial effusion. Conclusions Medical house staff with limited training in echocardiography can use point-of-care echocardiography to assess left ventricular function and pericardial effusion with moderate accuracy that is lower than that of standard echocardiography. Assessment of valvular disease and other diagnoses likely requires more training and/or experience in echocardiography.
引用
收藏
页码:476 / +
页数:6
相关论文
共 32 条
[31]   Left ventricular hypertrophy screening using a hand-held ultrasound device [J].
Vourvouri, EC ;
Poldermans, D ;
Schinkel, AFL ;
Koroleva, LY ;
Sozzi, FB ;
Parharidis, GE ;
Bax, JJ ;
Roelandt, JRTC .
EUROPEAN HEART JOURNAL, 2002, 23 (19) :1516-1521
[32]   Experience with an ultrasound stethoscope [J].
Vourvouri, EC ;
Poldermans, D ;
De Sutter, J ;
Sozzi, FB ;
Izzo, P ;
Roelandt, JRTC .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (01) :80-85