Enhanced detection of pathogenic enteric viruses in coastal marine environment by concentration using methacrylate monolithic chromatographic supports paired with quantitative PCR

被引:8
作者
Balasubramanian, Mukundh N. [1 ]
Racki, Nejc [2 ]
Goncalves, Jose
Kovac, Katarina [1 ]
Znidaric, Magda T. [2 ]
Turk, Valentina [3 ]
Ravnikar, Maja [2 ]
Gutierrez-Aguirre, Ion [2 ]
机构
[1] BioSistemika LLC, Koprska 98, SI-1000 Ljubljana, Slovenia
[2] Natl Inst Biol, Dept Biotechnol & Syst Biol, Vecna Pot 111, SI-1000 Ljubljana, Slovenia
[3] Natl Inst Biol, Marine Biol Stn, Fornace 41, SI-6330 Piran, Slovenia
关键词
Rotavirus; Norovirus; Seawater; Fecal contamination; qPCR; Sewage; WATER SAMPLES; DRINKING-WATER; HEALTH-RISKS; NOROVIRUS; ROTAVIRUS; SEAWATER; PURIFICATION; ENTEROVIRUS; ADSORPTION; PROTEIN;
D O I
10.1016/j.watres.2016.10.020
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Currently, around 50% of the world's population lives in towns and cities within 100 km of the coast. Monitoring of viruses that are frequently present in contaminated coastal environments, such as rota virus (RoV) and norovirus (NoV), which are also the major cause of human viral gastroenteritis, is essential to ensure the safe use of these water bodies. Since exposure to as few as 10-100 particles of RoV or NoV may induce gastrointestinal disease, there is a need to develop a rapid and sensitive diagnostic method for their detection in coastal water samples. In this study, we evaluate the application of methacrylate monolithic chromatographic columns, commercially available as convective interaction media (CIM (R)), to concentrate pathogenic enteric viruses from saline water samples prior to virus quantification by one-step reverse transcription quantitative PCR (RT-qPCR). Using RoV and NoV as model enteric viruses, we present our results on the most effective viral concentration conditions from saline water matrices using butyl (C4) hydrophobic interaction monolithic support (CIM (R) C4). C4 monolithic columns exhibit a good capacity to bind both RoV and NoV and both viruses can be eluted in a single step. Our protocol using a 1 ml C4 column enables processing of 400 ml saline water samples in less than 60 min and increases the sensitivity of RoV and NoV detection by approximately 50-fold and 10-fold respectively. The protocol was also scaled up using larger capacity 8 ml C4 columns to process 4000 ml of seawater samples with concentration factors of 300-fold for RoV and 40-fold for NoV, without any significant increase in processing time. Furthermore, C4 monolithic columns were adapted for field use in an on-site application of RoV concentration from seawater samples with performance equivalent to that of the reference laboratory setup. Overall, the results from successful deployment of CIM C4 columns for concentration of rotavirus and norovirus in seawater samples reiterate the utility of monolithic supports as efficient, scalable and modular preparative tools for processing environmental water samples to enhance viral detection using molecular methods. (C) 2016 BioSistemika LLC. Published by Elsevier Ltd.
引用
收藏
页码:405 / 414
页数:10
相关论文
共 45 条
  • [1] Comparison of Concentration Methods for Quantitative Detection of Sewage-Associated Viral Markers in Environmental Waters
    Ahmed, W.
    Harwood, V. J.
    Gyawali, P.
    Sidhu, J. P. S.
    Toze, S.
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2015, 81 (06) : 2042 - 2049
  • [2] Convective Interaction Media short monolithic columns: Enabling chromatographic supports for the separation and purification of large biomolecules
    Barut, M
    Podgornik, A
    Brne, P
    Strancar, A
    [J]. JOURNAL OF SEPARATION SCIENCE, 2005, 28 (15) : 1876 - 1892
  • [3] Discovery of rotavirus: Implications for Child health
    Bishop, Ruth
    [J]. JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2009, 24 : S81 - S85
  • [4] Brown S., 2013, COASTAL HAZARDS, P117, DOI [DOI 10.1007/978-94-007-5234-45, 10.1007/978-94-007-5234-4_5, DOI 10.1007/978-94-007-5234-4_5]
  • [5] Development and application of a one-step low cost procedure to concentrate viruses from seawater samples
    Calgua, B.
    Mengewein, A.
    Grunert, A.
    Bofill-Mas, S.
    Clemente-Casares, P.
    Hundesa, A.
    Wyn-Jones, A. P.
    Lopez-Pila, J. M.
    Girones, R.
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2008, 153 (02) : 79 - 83
  • [6] Methods for primary concentration of viruses from water samples: a review and meta-analysis of recent studies
    Cashdollar, J. L.
    Wymer, L.
    [J]. JOURNAL OF APPLIED MICROBIOLOGY, 2013, 115 (01) : 1 - 11
  • [7] Development and Evaluation of EPA Method 1615 for Detection of Enterovirus and Norovirus in Water
    Cashdollar, Jennifer L.
    Brinkman, Nichole E.
    Griffin, Shannon M.
    McMinn, Brian R.
    Rhodes, Eric R.
    Varughese, Eunice A.
    Grimm, Ann C.
    Parshionikar, Sandhya U.
    Wymer, Larry
    Fout, G. Shay
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2013, 79 (01) : 215 - 223
  • [8] Adsorption and Aggregation Properties of Norovirus GI and GII Virus-like Particles Demonstrate Differing Responses to Solution Chemistry
    da Silva, Allegra K.
    Kavanagh, Owen V.
    Estes, Mary K.
    Elimelech, Menachem
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2011, 45 (02) : 520 - 526
  • [9] Evaluation of viral concentration methods from irrigation and processing water
    De Keuckelaere, Ann
    Baert, Leen
    Duarte, Alexandra
    Stals, Ambroos
    Uyttendaele, Mieke
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2013, 187 (02) : 294 - 303
  • [10] Enteric viruses of humans and animals in aquatic environments: Health risks, detection, and potential water quality assessment tools
    Fong, TT
    Lipp, EK
    [J]. MICROBIOLOGY AND MOLECULAR BIOLOGY REVIEWS, 2005, 69 (02) : 357 - +