Ultrasonically induced lung hemorrhage in young swine

被引:53
作者
Dalecki, D
Child, SZ
Raeman, CH
Cox, C
Carstensen, EL
机构
[1] UNIV ROCHESTER,DEPT BIOSTAT,ROCHESTER,NY 14627
[2] UNIV ROCHESTER,ROCHESTER CTR BIOMED ULTRASOUND,ROCHESTER,NY 14627
关键词
lung hemorrhage; pulsed ultrasound; swine; bioeffects;
D O I
10.1016/S0301-5629(97)00070-7
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ten-day old swine were used in the final step of a study of the age dependence of the threshold for lung hemorrhage resulting from exposure to diagnostically relevant levels of pulsed ultrasound, A 2.3-MHz focused transducer (pulse length of 10 mu s, 100-Hz pulse repetition frequency) was incremented vertically at several sites for a distance of 2 or 2.5 cm over the chest of the subject for a total exposure period of 16 or 20 min, The procedure was repeated at a total of four sites per animal, Animals were euthanized and lungs were scored by visual inspection for numbers and areas of gross hemorrhages. The threshold level for hemorrhage was approximately 1.3-MPa peak positive pressure in mater at the surface of the animal or, at the surface of the lung, 0.8-MPa peak positive pressure, 0.8-MPa fundamental pressure, 0.7-MPa maximum negative pressure and 20 Wcm(-2) pulse average intensity. These values are essentially the same as those reported previously for neonatal swine, and neonatal, juvenile and adult mice, (C) 1997 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:777 / 781
页数:5
相关论文
共 15 条
[1]   Thresholds for ultrasonically induced lung hemorrhage in neonatal swine [J].
Baggs, R ;
Penney, DP ;
Cox, C ;
Child, SZ ;
Raeman, CH ;
Dalecki, D ;
Carstensen, EL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (01) :119-128
[2]   LUNG DAMAGE FROM EXPOSURE TO PULSED ULTRASOUND [J].
CHILD, SZ ;
HARTMAN, CL ;
SCHERY, LA ;
CARSTENSEN, EL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (08) :817-825
[3]  
COX C, 1984, APPL STAT-J ROY ST C, V33, P18
[4]   Hemolysis in vivo from exposure to pulsed ultrasound [J].
Dalecki, D ;
Raeman, CH ;
Child, SZ ;
Cox, C ;
Francis, CW ;
Meltzer, RS ;
Carstensen, EL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (02) :307-313
[5]   Age dependence of ultrasonically induced lung hemorrhage in mice [J].
Dalecki, D ;
Child, SZ ;
Raeman, CH ;
Cox, C ;
Penney, DP ;
Carstensen, EL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (05) :767-776
[6]   EFFECTS OF PULSED ULTRASOUND ON THE MOUSE NEONATE - HIND-LIMB PARALYSIS AND LUNG HEMORRHAGE [J].
FRIZZELL, LA ;
CHEN, E ;
LEE, C .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (01) :53-63
[7]   MICROSCOPIC LUNG ALTERATIONS AND REDUCTION OF RESPIRATION RATE IN INSONATED ANESTHETIZED SWINE [J].
HARRISON, GH ;
EDDY, HA ;
WANG, JP ;
LIBERMAN, FZ .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (07) :981-983
[8]   Direct evidence of cavitation in vivo from diagnostic ultrasound [J].
Holland, CK ;
Deng, CX ;
Apfel, RE ;
Alderman, JL ;
Fernandez, LA ;
Taylor, KJW .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (07) :917-925
[9]  
McCullagh P., 1989, GEN LINEAR MODELS, DOI [DOI 10.1007/978-1-4899-3242-6, 10.1201/9780203753736, DOI 10.2307/2347392]
[10]   MORPHOLOGICAL EFFECTS OF PULSED ULTRASOUND IN THE LUNG [J].
PENNEY, DP ;
SCHENK, EA ;
MALTBY, K ;
HARTMANRAEMAN, C ;
CHILD, SZ ;
CARSTENSEN, EL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (02) :127-135