Volumetric coronary angiography using the 256-detector row computed tomography scanner: Comparison in vivo and in vitro with porcine models

被引:22
作者
Mori, S
Kondo, C
Suzuki, N
Hattori, A
Kusakabe, M
Endo, M
机构
[1] Natl Inst Radiol Sci, Dept Med Phys, Inage Ku, Chiba 2638555, Japan
[2] Tokyo Womens Med Univ, Dept Radiol, Tokyo, Japan
[3] Jikei Univ, Sch Med, Inst High Dimens Med Imaging, Tokyo, Japan
[4] Univ Fukui, Fac Engn, Fukui 910, Japan
关键词
computed tomography; coronary artery; dynamic; four-dimensional; imaging;
D O I
10.1080/02841850500479669
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the feasibility of volumetric cine imaging in human cardiac studies by comparing in vivo and in vitro coronary angiography using a 256-detector row computed tomography (CT) without ECG gating. Material and Methods: The left and right coronary arteries of two domestic pigs were scanned in vivo and in vitro in cine mode using the 256-detector row CT. The device scanned approximately 100 mm in the cranio-caudal direction with one rotation, with a slice thickness of 0.5 mm. Results: The coronary arteries could be observed to the third-degree branches in vitro, but could be visualized clearly only to the proximal portion (first-degree or second-degree branches) in vivo. Conclusion: Application of cardiac volumetric cine imaging with 256-detector row CT may be a promising means of obtaining diagnostic information and has potential for adoption to human studies.
引用
收藏
页码:186 / 191
页数:6
相关论文
共 18 条
[1]   Comparison of image quality in contrast-enhanced coronary artery visualization by electron beam tomography and retrospectively electrocardiogram-gated multislice spiral computed tomography [J].
Achenbach, S ;
Giesler, T ;
Ropers, D ;
Ulzheimer, S ;
Anders, K ;
Wenkel, E ;
Pohle, K ;
Kachelriess, M ;
Derlien, H ;
Kalender, WA ;
Daniel, WG ;
Bautz, W ;
Baum, U .
INVESTIGATIVE RADIOLOGY, 2003, 38 (02) :119-128
[2]   Development and performance evaluation of the first model of 4-D CT-scanner [J].
Endo, M ;
Mori, S ;
Tsunoo, T ;
Kandatsu, S ;
Tanada, S ;
Aradate, H ;
Saito, Y ;
Miyazaki, H ;
Satoh, K ;
Matsusita, S ;
Kusakabe, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) :1667-1671
[3]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[4]   In vitro coronary artery imaging with sixteen-slice helical computed tomography [J].
Knollmann, F ;
Yankah, CA ;
Kaisers, U ;
Felix, R .
ACTA RADIOLOGICA, 2004, 45 (02) :159-163
[5]   Coronary arteries: Retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window [J].
Kopp, AF ;
Schroeder, S ;
Kuettner, A ;
Heuschmid, M ;
Georg, C ;
Ohnesorge, B ;
Kuzo, R ;
Claussen, CD .
RADIOLOGY, 2001, 221 (03) :683-688
[6]   Non-invasive intravenous coronary angiography using electron beam tomography and multislice computed tomography [J].
Leber, AW ;
Knez, A ;
Becker, C ;
Becker, A ;
White, C ;
Thilo, C ;
Reiser, M ;
Haberl, R ;
Steinbeck, G .
HEART, 2003, 89 (06) :633-639
[7]   Image quality of noninvasive coronary angiography using multislice spiral computed tomography and electron-beam computed tomography -: Intraindividual comparison in an animal model [J].
Lembcke, A ;
Wiese, TH ;
Schnorr, J ;
Wagner, S ;
Mews, J ;
Kroencke, TJ ;
Enzweiler, CNH ;
Hamm, B ;
Taupitz, M .
INVESTIGATIVE RADIOLOGY, 2004, 39 (06) :357-364
[8]  
Mahnken AH, 2005, INVEST RADIOL, V40, P8
[9]   Enlarged longitudinal dose profiles in cone-beam CT and the need for modified dosimetry [J].
Mori, S ;
Endo, M ;
Nishizawa, K ;
Tsunoo, T ;
Aoyama, T ;
Fujiwara, H ;
Murase, K .
MEDICAL PHYSICS, 2005, 32 (04) :1061-1069
[10]   Clinical potentials of the prototype 256-detector row CT-scanner [J].
Mori, S ;
Endo, M ;
Obata, T ;
Murase, K ;
Fujiwara, H ;
Susumu, K ;
Tanada, S .
ACADEMIC RADIOLOGY, 2005, 12 (02) :148-154