Acceleration-Selective Arterial Spin Labeling

被引:39
作者
Schmid, Sophie [1 ]
Ghariq, Eidrees [1 ]
Teeuwisse, Wouter M. [1 ]
Webb, Andrew [1 ]
van Osch, Matthias J. P. [1 ,2 ]
机构
[1] Leiden Univ, Med Ctr, CJ Gorter Ctr High Field MRI, Dept Radiol, NL-2333 ZA Leiden, Netherlands
[2] Leiden Inst Brain & Cognit, Leiden, Netherlands
关键词
arterial spin labeling; acceleration selective; perfusion imaging; spatially nonselective labeling; DIFFUSION MRI; VELOCITY; INVERSION; BLOOD; TIME; SENSITIVITY; REDUCTION; BRAIN; BOLD; T-1;
D O I
10.1002/mrm.24650
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
In this study, a new arterial spin labeling (ASL) method with spatially nonselective labeling is introduced, based on the acceleration of flowing spins, which is able to image brain perfusion with minimal contamination from venous signal. This method is termed acceleration-selective ASL (AccASL) and resembles velocity-selective ASL (VSASL), with the difference that AccASL is able to discriminate between arterial and venous components in a single preparation module due to the higher acceleration on the arterial side of the microvasculature, whereas VSASL cannot make this distinction unless a second labeling module is used. A difference between AccASL and VSASL is that AccASL is mainly cerebral blood volume weighted, whereas VSASL is cerebral blood flow weighted. AccASL exploits the principles of acceleration-encoded magnetic resonance angiography by using motion-sensitizing gradients in a T-2-preparation module. This method is demonstrated in healthy volunteers for a range of cutoff accelerations. Additionally, AccASL is compared with VSASL and pseudo-continuous ASL, and its feasibility in functional MRI is demonstrated. Compared with VSASL with a single labeling module, a strong and significant reduction in venous label is observed. The resulting signal-to-noise ratio is comparable to pseudo-continuous ASL and robust activation of the visual cortex is observed. Magn Reson Med 71:191-199, 2014. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:191 / 199
页数:9
相关论文
共 36 条
[1]
Experimental design and the relative sensitivity of BOLD and perfusion fMRI [J].
Aguirre, GK ;
Detre, JA ;
Zarahn, E ;
Alsop, DC .
NEUROIMAGE, 2002, 15 (03) :488-500
[2]
Reduced transit-time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow [J].
Alsop, DC ;
Detre, JA .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1996, 16 (06) :1236-1249
[3]
A general kinetic model for quantitative perfusion imaging with arterial spin labeling [J].
Buxton, RB ;
Frank, LR ;
Wong, EC ;
Siewert, B ;
Warach, S ;
Edelman, RR .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (03) :383-396
[4]
Magnetic resonance perfusion imaging in acute ischemic stroke using continuous arterial spin labeling [J].
Chalela, JA ;
Alsop, DC ;
Gonzalez-Atavales, JB ;
Maldjian, JA ;
Kasner, SE ;
Detre, JA .
STROKE, 2000, 31 (03) :680-687
[5]
Rapid T1 mapping using multislice echo planar imaging [J].
Clare, S ;
Jezzard, P .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) :630-634
[6]
A REDUCED POWER SELECTIVE ADIABATIC SPIN-ECHO PULSE SEQUENCE [J].
CONOLLY, S ;
GLOVER, G ;
NISHIMURA, D ;
MACOVSKI, A .
MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (01) :28-38
[7]
Continuous Flow-Driven Inversion for Arterial Spin Labeling Using Pulsed Radio Frequency and Gradient Fields [J].
Dai, Weiying ;
Garcia, Dairon ;
de Bazelaire, Cedric ;
Alsop, David C. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (06) :1488-1497
[8]
PERFUSION IMAGING [J].
DETRE, JA ;
LEIGH, JS ;
WILLIAMS, DS ;
KORETSKY, AP .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) :37-45
[9]
Evaluation of systematic quantification errors in velocity-selective arterial spin labeling of the brain [J].
Duhamel, G ;
de Bazelaire, U ;
Alsop, DC .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (01) :145-153
[10]