An integrated microfluidic platform for sensitive and rapid detection of biological toxins

被引:97
作者
Meagher, Robert J. [1 ]
Hatch, Anson V. [1 ]
Renzi, Ronald F. [1 ]
Singh, Anup K. [1 ]
机构
[1] Sandia Natl Labs, Livermore, CA 94550 USA
关键词
D O I
10.1039/b815152k
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Towards designing a portable diagnostic device for detecting biological toxins in bodily fluids, we have developed microfluidic chip-based immunoassays that are rapid (< 20 minutes), require minimal sample volume (< 10 mu L) and have appreciable sensitivity and dynamic range (mu M-pM). The microfluidic chip is being integrated with miniaturized electronics, optical elements, fluid-handling components, and data acquisition software to develop a portable, self-contained device. The device is intended for rapid, point-of-care (and, in future, point-of-incident) testing in case of an accidental or intentional exposure/intoxication to biotoxins. Detection of toxins and potential host-response markers is performed using microfluidic electrophoretic immunoassays integrated with sample preconcentration and mixing of analytes with fluorescently labeled antibodies. Preconcentration is enabled by photopolymerizing a thin, nanoporous membrane with a MW cut-off of similar to 10 kDa in the sample loading region of the chip. Polymeric gels with larger pores are located adjacent to the size exclusion membrane to perform electrophoretic separation of antibody-analyte complex and excess antibody. Measurement of the ratio of bound and unbound immune-complex using sensitive laser-induced fluorescence detection provides quantitation of analyte in the sample. We have demonstrated electrophoretic immunoassays for the biotoxins ricin, Shiga toxin I, and Staphylococcal enterotoxin B (SEB). With off-chip mixing and no sample preconcentration, the limits of detection (LOD) were 300 pM for SEB, 500 pM for Shiga toxin I, and 20 nM for ricin. With a 10 min on-chip preconcentration, the LOD for SEB is < 10 pM. The portable device being developed is readily applicable to detection of proteinaceous biomarkers of many other diseases and is intended to represent the next-generation diagnostic devices capable of rapid and quantitative measurements of multiple analytes simultaneously.
引用
收藏
页码:2046 / 2053
页数:8
相关论文
共 52 条
[1]  
[Anonymous], 1997, MED ASPECTS CHEM BIO
[2]   Protein sizing on a microchip [J].
Bousse, L ;
Mouradian, S ;
Minalla, A ;
Yee, H ;
Williams, K ;
Dubrow, R .
ANALYTICAL CHEMISTRY, 2001, 73 (06) :1207-1212
[3]  
Brahmasandra SN, 2001, ELECTROPHORESIS, V22, P300, DOI 10.1002/1522-2683(200101)22:2<300::AID-ELPS300>3.0.CO
[4]  
2-F
[5]   Flexibility - the guiding principle for antibody manufacturing [J].
Carson, KL .
NATURE BIOTECHNOLOGY, 2005, 23 (09) :1054-1058
[6]   Development of a multichannel microfluidic analysis system employing affinity capillary electrophoresis for immunoassay [J].
Cheng, SB ;
Skinner, CD ;
Taylor, J ;
Attiya, S ;
Lee, WE ;
Picelli, G ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 2001, 73 (07) :1472-1479
[7]   Microchip-based capillary electrophoresis for immunoassays: Analysis of monoclonal antibodies and theophylline [J].
Chiem, N ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1997, 69 (03) :373-378
[8]   A microchip-based multianalyte assay system for the assessment of cardiac risk [J].
Christodoulides, N ;
Tran, M ;
Floriano, PN ;
Rodriguez, M ;
Goodey, A ;
Ali, M ;
Neikirk, D ;
McDevitt, JT .
ANALYTICAL CHEMISTRY, 2002, 74 (13) :3030-3036
[9]   GLASS CHIPS FOR HIGH-SPEED CAPILLARY ELECTROPHORESIS SEPARATIONS WITH SUBMICROMETER PLATE HEIGHTS [J].
EFFENHAUSER, CS ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1993, 65 (19) :2637-2642
[10]   Microchip separations of protein biotoxins using an integrated hand-held device [J].
Fruetel, JA ;
Renzi, RF ;
VanderNoot, VA ;
Stamps, J ;
Horn, BA ;
West, JAA ;
Ferko, S ;
Crocker, R ;
Bailey, CG ;
Arnold, D ;
Wiedenman, B ;
Choi, WY ;
Yee, D ;
Shokair, I ;
Hasselbrink, E ;
Paul, P ;
Rakestraw, D ;
Padgen, D .
ELECTROPHORESIS, 2005, 26 (06) :1144-1154