Transradial coronary brachytherapy with the novoste beta-rail system

被引:4
作者
Bertrand, OF
De Larochellière, R
Gleeton, O
Plante, S
Tessier, M
Guimond, J
机构
[1] Laval Hosp, Quebec Heart Lung Inst, Intervent Cardiol Labs, St Foy, PQ G1V 4G5, Canada
[2] Laval Hosp, Quebec Heart Lung Inst, Nucl Med Dept, Quebec City, PQ, Canada
关键词
PTCA; IVUS; radiation; restenosis; isotope;
D O I
10.1002/ccd.10083
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We report our initial experience in 10 consecutive patients who underwent transradial coronary brachytherapy for in-stent restenosis using a Sr-90/Y source and the Novoste Beta-Rail system. In all patients, procedures were successfully completed using a right transradial approach. We performed the procedures with the Beta-Rail catheter using 7 Fir (Zuma II, Medtronic, MN, n = 5) or 8 Fr (Cordis, Miami, FL; n = 5) guiding catheters. All lesions were successfully dilated and no additional stent was inserted. We used a 40 mm source (n = 3) or a 60 mm source (n = 7) with manual stepping in four cases. In three cases, we did one stepping, and in one case, we did three steppings, The mean dwell time was 195 +/- 44 sec. The mean delivered dose was 23 +/- 3 Gy at 2 mm distance from the source. No radiation treatment was interrupted. Mean fluoroscopy time was 26 +/- 13 min. Procedural success was achieved in all patients. Three patients had mild CK elevations (< 3 times upper normal limit). All patients were pretreated with clopidogrel (300 mg) and combined treatment with aspirin + clopidogrel is to be continued for at least 1 year. Clinical follow-up up to 3 months has not yielded any complication and all patients have remained free from angina. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:362 / 366
页数:5
相关论文
共 11 条
[1]  
Barbeau G, 2001, J AM COLL CARDIOL, V37, p34A
[2]  
Bertrand OF, 1997, EUR HEART J, V18, P1385
[3]  
Bonan R, 1999, J INVASIVE CARDIOL, V11, P749
[4]  
Campeau L, 2001, CAN J CARDIOL, V17, P319
[5]   Guidance of intracoronary radiation therapy based on dose-volume histograms derived from quantitative intravascular ultrasound [J].
Carlier, SG ;
Marijnissen, JPA ;
Coen, VLMA ;
van der Giessen, WJ ;
Sabate, M ;
Ligthart, J ;
den Boer, A ;
Céspedes, IE ;
Li, WG ;
van der Steen, AFW ;
Levendag, PC ;
Serruys, PW .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) :772-778
[6]  
LASKEY W, 2000, LATE CLIN ANGIOGRAPH
[7]   Effects of intracoronary β-radiation therapy after coronary angioplasty -: An intravascular ultrasound study [J].
Meerkin, D ;
Tardif, JC ;
Crocker, IR ;
Arsenault, A ;
Joyal, M ;
Lucier, G ;
King, SB ;
Williams, DO ;
Serruys, PW ;
Bonan, R .
CIRCULATION, 1999, 99 (13) :1660-1665
[8]  
POPMA JJ, 2000, LATE CLIN ANGIOGRAPH
[9]   Catheter-based radiotherapy to inhibit restenosis after coronary stenting [J].
Teirstein, PS ;
Massullo, V ;
Jani, S ;
Popma, JJ ;
Mintz, GS ;
Russo, RJ ;
Schatz, RA ;
Guarneri, EM ;
Steuterman, S ;
Morris, NB ;
Leon, MB ;
Tripuraneni, P .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (24) :1697-1703
[10]   Two-year follow-up after beta and gamma intracoronary radiation therapy for patients with diffuse in-stent restenosis [J].
Waksman, R ;
Ajani, AE ;
White, RL ;
Pinnow, E ;
Mehran, R ;
Bui, AB ;
Deible, R ;
Gruberg, L ;
Mintz, GS ;
Satler, LF ;
Pichard, AD ;
Kent, KM ;
Lindsay, J .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (04) :425-+