Catheter-based radiotherapy to inhibit restenosis after coronary stenting

被引:700
作者
Teirstein, PS
Massullo, V
Jani, S
Popma, JJ
Mintz, GS
Russo, RJ
Schatz, RA
Guarneri, EM
Steuterman, S
Morris, NB
Leon, MB
Tripuraneni, P
机构
[1] SCRIPPS CLIN,DIV RADIAT ONCOL,LA JOLLA,CA 92037
[2] WASHINGTON HOSP CTR,DIV CARDIOL,WASHINGTON,DC 20010
关键词
D O I
10.1056/NEJM199706123362402
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background In animal models of coronary restenosis, intracoronary radiotherapy has been shown to reduce the intimal hyperplasia that is a part of restenosis. We studied the safety and efficacy of catheter-based intracoronary gamma radiation plus stenting to reduce coronary restenosis in patients with previous restenosis. Methods Patients with restenosis underwent coronary stenting, as required, and balloon dilation and were then randomly assigned to receive catheter-based irradiation with iridium-192 or placebo. Clinical follow-up was performed, with quantitative coronary angiographic and intravascular ultrasonographic measurements at six months. Results Fifty-five patients were enrolled; 26 were assigned to the iridium-192 group and 29 to the placebo group. Angiographic studies were performed in 53 patients (96 percent) at a mean (+/-SD) of 6.7+/-2.2 months. The mean minimal luminal diameter at follow-up was larger in the iridium-192 group than in the placebo group (2.43+/-0.78 mm vs. 1.85+/-0.89 mm, P=0.02). Late luminal loss was significantly lower in the iridium-192 group than in the placebo group (0.38+/-1.06 mm vs. 1.03+/-0.97 mm, P=0.03). Angiographically identified restenosis (stenosis of 50 percent or more of the luminal diameter at follow-up) occurred in 17 percent of the patients in the iridium-192 group, as compared with 54 percent of those in the placebo group (P=0.01). There were no apparent complications of the treatment. Conclusions In this preliminary, short-term study of patients with previous coronary restenosis, coronary stenting followed by catheter-based intracoronary radiotherapy substantially reduced the rate of subsequent restenosis. (C) 1997, Massachusetts Medical Society.
引用
收藏
页码:1697 / 1703
页数:7
相关论文
共 35 条
  • [1] BOTTCHER HD, 1994, INT J RADIAT ONCOL, V29, P183
  • [2] CONDADO JA, 1996, CIRCULATION S1, V94, P209
  • [3] IRRADIATION-RELATED ISCHEMIC-HEART-DISEASE
    CORN, BW
    TROCK, BJ
    GOODMAN, RL
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 1990, 8 (04) : 741 - 750
  • [4] SMALL STENT SIZE AND INTIMAL HYPERPLASIA CONTRIBUTE TO RESTENOSIS - A VOLUMETRIC INTRAVASCULAR ULTRASOUND ANALYSIS
    DUSSAILLANT, GR
    MINTZ, GS
    PICHARD, AD
    KENT, KM
    SATLER, LF
    POPMA, JJ
    WONG, SC
    LEON, MB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (03) : 720 - 724
  • [5] A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE
    FISCHMAN, DL
    LEON, MB
    BAIM, DS
    SCHATZ, RA
    SAVAGE, MP
    PENN, I
    DETRE, K
    VELTRI, L
    RICCI, D
    NOBUYOSHI, M
    CLEMAN, M
    HEUSER, R
    ALMOND, D
    TEIRSTEIN, PS
    FISH, RD
    COLOMBO, A
    BRINKER, J
    MOSES, J
    SHAKNOVICH, A
    HIRSHFELD, J
    BAILEY, S
    ELLIS, S
    RAKE, R
    GOLDBERG, S
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) : 496 - 501
  • [6] MECHANISMS OF RESTENOSIS AND REDILATION WITHIN CORONARY STENTS - QUANTITATIVE ANGIOGRAPHIC ASSESSMENT
    GORDON, PC
    GIBSON, CM
    COHEN, DJ
    CARROZZA, JP
    KUNTZ, RE
    BAIM, DS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (05) : 1166 - 1174
  • [7] EXPERIMENTAL THERAPEUTICS AND CLINICAL-STUDIES IN (RE)STENOSIS
    HANDLEY, DA
    [J]. MICRON, 1995, 26 (01) : 51 - 68
  • [8] HEBRLEIN C, 1995, CIRCULATION, V92, P1570
  • [9] Patterns and mechanisms of in-stent restenosis - A serial intravascular ultrasound study
    Hoffmann, R
    Mintz, GS
    Dussaillant, GR
    Popma, JJ
    Pichard, AD
    Satler, LF
    Kent, KM
    Griffin, J
    Leon, MB
    [J]. CIRCULATION, 1996, 94 (06) : 1247 - 1254
  • [10] NOVEL-APPROACH TO THE ANALYSIS OF RESTENOSIS AFTER THE USE OF 3 NEW CORONARY DEVICES
    KUNTZ, RE
    SAFIAN, RD
    LEVINE, MJ
    REIS, GJ
    DIVER, DJ
    BAIM, DS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (07) : 1493 - 1499