Fast-channel LSO detectors and fiber-optic encoding for excellent dual photon transmission measurements in PET

被引:8
作者
Jones, WF [1 ]
Moyers, JC [1 ]
Casey, ME [1 ]
Watson, CC [1 ]
Nutt, R [1 ]
机构
[1] CTI PET Syst Inc, Knoxville, TN 37932 USA
关键词
D O I
10.1109/23.790807
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Improved attenuation correction remains critical to PET. Currently with dual photon rotating rod sources, benefits of windowing are limited by counting losses of detectors nearest the rods, the near detectors. With single photon sources, improved statistics are offset by a greater need for collimation and more complex emission background correction. Now, a dual photon point source array with fast-channel, near detectors improves on these earlier techniques - here, adding transmission measurement to dual-head rotating PET. Arrays of collimated point sources (Ge-68/Ga - 3 to 21 per head) are aligned axially and orbit the FOV. With each source is a dedicated near detector (LSO crystal). Crystals couple to photomultipliers (PMTs). As the crystals are not "block" encoded, pulse-processing time is reduced (to 120 ns). Reduced processing time lowers dead time and permits hotter sources. For improved axial sampling, larger arrays (21 sources/head) may be configured. To reduce cost, crystals couple fiber-optically into unique PMT pairs - decreasing the total number of near-detector PMTs by 71%.
引用
收藏
页码:979 / 984
页数:6
相关论文
共 12 条
[1]  
Bailey D. L., 1997, Journal of Nuclear Medicine, V38, p113P
[2]  
BAILEY DL, 1997, IEEE NUCL SCI S C RE
[3]  
CARROLL LR, 1983, EM COM TOM CURRENT T
[4]   A MULTICRYSTAL 2-DIMENSIONAL BGO DETECTOR SYSTEM FOR POSITRON EMISSION TOMOGRAPHY [J].
CASEY, ME ;
NUTT, R .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) :460-463
[5]   Optical fiber readout of scintillator arrays using a multi-channel PMT: A high resolution PET detector for animal imaging [J].
Cherry, SR ;
Shao, YP ;
Siegel, S ;
Silverman, RW ;
Mumcuoglu, E ;
Meadors, K ;
Phelps, ME .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) :1932-1937
[6]   ATTENUATION CORRECTION IN PET USING SINGLE-PHOTON TRANSMISSION MEASUREMENT [J].
DEKEMP, RA ;
NAHMIAS, C .
MEDICAL PHYSICS, 1994, 21 (06) :771-778
[7]  
JONES W, 1995, IEEE NUCL SCI S C RE, P1026
[8]   OPTIMIZING ROD WINDOW WIDTH IN POSITRON EMISSION TOMOGRAPHY [J].
JONES, WF ;
DIGBY, WM ;
LUK, WK ;
CASEY, ME ;
BYARS, LG .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1995, 14 (02) :266-270
[9]   CONSTRUCTION OF A POSITRON EMISSION TOMOGRAPH WITH 2,4 MM DETECTORS [J].
MCINTYRE, JA ;
SPROSST, RL ;
WANG, KH .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) :425-427
[10]  
MEIKLE SR, 1995, J NUCL MED, V36, P1680