Renal arteries: Optimization of three-dimensional gadolinium-enhanced MR angiography with bolus-timing-independent fast multiphase acquisition in a single breath hold

被引:123
作者
Schoenberg, SO
Bock, M
Knopp, MV
Essig, M
Laub, G
Hawighorst, H
Zuna, I
Kallinowski, F
van Kaick, G
机构
[1] German Canc Res Ctr, Dept Radiol, D-69120 Heidelberg, Germany
[2] Siemens Med Syst Inc, Erlangen, Germany
[3] Univ Heidelberg Hosp, Dept Surg, Heidelberg, Germany
关键词
magnetic resonance (MR); maximum intensity projection; three-dimensional; vascular studies; renal arteries; MR;
D O I
10.1148/radiology.211.3.r99jn26667
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare two different three-dimensional (3D) gadolinium-enhanced magnetic resonance (MR) angiographic techniques. MATERIALS AND METHODS: In 26 patients suspected of having renal artery stenosis, results with fast multiphase 3D MR angiography were compared to those with standard 3D MR angiography in 37 patients. With both techniques, 31-second breath-hold acquisitions were Performed. Multiphase angiography comprised five discrete 6.4-second acquisitions without bolus timing, and standard angiography comprised a single acquisition based on test-bolus timing. Two readers evaluated images obtained with both techniques in terms of image quality, artifacts, and vessel conspicuity. Accuracy of findings on the multiphase 3D MR angiograms for assessment of renal artery stenosis was determined by comparing them to digital subtraction angiograms and surgical findings. RESULTS: In the early arterial phase, multiphase 3D MR angiograms showed no image degradation by venous overlay, whereas: standard 3D MR angiograms depicted at least minor overlay in 53 of 83 renal arteries (P < .001). Less parenchymal enhancement in the early arterial phase resulted in a higher vessel conspicuity for the divisions and segmental arteries(P < .001). Both readers detected and correctly graded 18 of 20 stenoses on the multiphase angiograms with almost perfect interobserver agreement (kappa > 0.89). CONCLUSION: Renal multiphase 3D MR angiography is an accurate technique requiring no bolus timing. The performance of early arterial phase imaging leads to improved depiction, particularly of the distal renovascular tree,compared to that with standard single-phase 3D MR angiography.
引用
收藏
页码:667 / 679
页数:13
相关论文
共 28 条
[2]   RENAL-ARTERY BLOOD-FLOW - QUANTITATION WITH PHASE-CONTRAST MR-IMAGING WITH AND WITHOUT BREATH-HOLDING [J].
DEBATIN, JF ;
TING, RH ;
WEGMULLER, H ;
SOMMER, FG ;
FREDRICKSON, JO ;
BROSNAN, TJ ;
BOWMAN, BS ;
MYERS, BD ;
HERFKENS, RJ ;
PELC, NJ .
RADIOLOGY, 1994, 190 (02) :371-378
[3]   Renal artery stenosis: Value of screening with three-dimensional phase-contrast MR angiography with a phased-array multicoil [J].
DeCobelli, F ;
Mellone, R ;
Salvioni, M ;
Vanzulli, A ;
Sironi, S ;
Manunta, P ;
Lanzani, C ;
Bianchi, G ;
DelMaschio, A .
RADIOLOGY, 1996, 201 (03) :697-703
[4]   Renovascular disease in patients with hypertension: Detection with systolic and diastolic gating in three-dimensional, phase-contrast MR angiography [J].
deHaan, MW ;
Kouwenhoven, M ;
Thelissen, GRP ;
Koster, D ;
Kessels, AGH ;
deLeeuw, PW ;
vanEngelshoven, JMA .
RADIOLOGY, 1996, 198 (02) :449-456
[5]  
GOLDFARB JW, 1997, P ISMRM 5 ANN M VANC, P200
[6]   Evaluation of the aortoiliac and renal arteries: Comparison of breath-hold, contrast-enhanced, three-dimensional MR angiography with conventional catheter angiography [J].
Hany, TF ;
Debatin, JF ;
Leung, DA ;
Pfammatter, T .
RADIOLOGY, 1997, 204 (02) :357-362
[7]   Optimization of contrast timing for breath-hold three-dimensional MR angiography [J].
Hany, TF ;
McKinnon, GC ;
Leung, DA ;
Pfammatter, T ;
Debatin, JF .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (03) :551-556
[8]   Time-resolved contrast-enhanced 3D MR angiography [J].
Korosec, FR ;
Frayne, R ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) :345-351
[9]  
LEUNG DA, 1997, P 5 M INT SOC MAGN R, P124
[10]  
LEUNG DA, 1996, RADIOLOGY, V201, P569