An original emission tomograph for in vivo brain imaging of small animals

被引:16
作者
Ochoa, AV [1 ]
Ploux, L [1 ]
Mastrippolito, R [1 ]
Charon, Y [1 ]
Laniece, P [1 ]
Pinot, L [1 ]
Valentin, L [1 ]
机构
[1] UNIV PARIS 07,GRP MODELISAT PHYS & INTERFACES BIOL,F-75005 PARIS,FRANCE
关键词
D O I
10.1109/23.632717
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The principle of a new tomograph (TOHR) dedicated for small volume analysis with very high resolution is presented in this paper. We use uncorrelated multi-photon (X or gamma rays) radioisotopes and a large solid angle focusing collimator to produce tomographic images without a reconstruction algorithm. With this device, detection efficiency and resolution are independent and submillimeter resolution can be achieved. A feasibility study shows that collimators made with a stack of chemically etched plates can achieve the predicted performances of TOHR. We discuss its potential in rat brain tomography by simulating a realistic neuropharmacological experiment using a 1.4 mm resolution prototype of the TOHR under development.
引用
收藏
页码:1533 / 1537
页数:5
相关论文
共 20 条
[1]   THE DESIGN AND PHYSICAL CHARACTERISTICS OF A SMALL ANIMAL POSITRON EMISSION TOMOGRAPH [J].
BLOOMFIELD, PM ;
RAJESWARAN, S ;
SPINKS, TJ ;
HUME, SP ;
MYERS, R ;
ASHWORTH, S ;
CLIFFORD, KM ;
JONES, WF ;
BYARS, LG ;
YOUNG, J ;
ANDREACO, M ;
WILLIAMS, CW ;
LAMMERTSMA, AA ;
JONES, T .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (06) :1105-1126
[2]   EMISSION COMPUTER-ASSISTED TOMOGRAPHY WITH SINGLE-PHOTON AND POSITRON-ANNIHILATION PHOTON EMITTERS [J].
BUDINGER, TF ;
DERENZO, SE ;
GULLBERG, GT ;
GREENBERG, WL ;
HUESMAN, RH .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1977, 1 (01) :131-145
[3]  
CASSEN B, 1950, NUCLEONICS FEB, P78
[4]   Optical fiber readout of scintillator arrays using a multi-channel PMT: A high resolution PET detector for animal imaging [J].
Cherry, SR ;
Shao, YP ;
Siegel, S ;
Silverman, RW ;
Mumcuoglu, E ;
Meadors, K ;
Phelps, ME .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) :1932-1937
[5]  
COURTIAL J, 1964, P S MED RAD SCANN IN
[6]   A HIGH-RESOLUTION SPECT SYSTEM BASED ON A MICROCHANNEL-PLATE IMAGER [J].
DILMANIAN, FA ;
WEBER, DA ;
CODERRE, JA ;
JOEL, DD ;
SHI, KC ;
MEINKEN, GE ;
SOM, P ;
TANG, YN ;
VOLKOW, ND ;
YEE, C ;
BRILL, AB ;
WATANABE, M ;
INUZUKA, E ;
OBA, K ;
GERSON, R ;
IIDA, H ;
HIRUMA, A .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) :687-695
[7]   NCQ 298, A NEW SELECTIVE IODINATED SALICYLAMIDE LIGAND FOR THE LABELING OF DOPAMINE-D2 RECEPTORS [J].
HALL, H ;
HOGBERG, T ;
HALLDIN, C ;
KOHLER, C ;
STROM, P ;
ROSS, SB ;
LARSSON, SA ;
FARDE, L .
PSYCHOPHARMACOLOGY, 1991, 103 (01) :6-18
[8]  
ISHIZU K, 1995, J NUCL MED, V36, P2282
[9]   Initial results from the Sherbrooke avalanche photodiode positron tomograph [J].
Lecomte, R ;
Cadorette, J ;
Rodrigue, S ;
Lapointe, D ;
Rouleau, D ;
Bentourkia, M ;
Yao, R ;
Msaki, P .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) :1952-1957
[10]  
Lederer CM., 1978, Table of isotopes