共 8 条
Imaging and quantifying transverse flow velocity with the Doppler bandwidth in a phase-resolved functional optical coherence tomography
被引:95
作者:

Ren, HW
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Calif Irvine, Ctr Biomed Engn, Irvine, CA 92612 USA Univ Calif Irvine, Ctr Biomed Engn, Irvine, CA 92612 USA

Brecke, KM
论文数: 0 引用数: 0
h-index: 0
机构: Univ Calif Irvine, Ctr Biomed Engn, Irvine, CA 92612 USA

Ding, ZH
论文数: 0 引用数: 0
h-index: 0
机构: Univ Calif Irvine, Ctr Biomed Engn, Irvine, CA 92612 USA

Zhao, YH
论文数: 0 引用数: 0
h-index: 0
机构: Univ Calif Irvine, Ctr Biomed Engn, Irvine, CA 92612 USA

Nelson, JS
论文数: 0 引用数: 0
h-index: 0
机构: Univ Calif Irvine, Ctr Biomed Engn, Irvine, CA 92612 USA

Chen, ZP
论文数: 0 引用数: 0
h-index: 0
机构: Univ Calif Irvine, Ctr Biomed Engn, Irvine, CA 92612 USA
机构:
[1] Univ Calif Irvine, Ctr Biomed Engn, Irvine, CA 92612 USA
[2] Univ Calif Irvine, Beckman Laser Inst, Irvine, CA 92612 USA
关键词:
D O I:
10.1364/OL.27.000409
中图分类号:
O43 [光学];
学科分类号:
070207 ;
0803 ;
摘要:
The Doppler bandwidth extracted from the standard deviation of the frequency shift in phase-resolved functional optical coherence tomography (F-OCT) was used to image the velocity component that is transverse to the optical probing beam. It was found that above a certain threshold level the Doppler bandwidth is a linear function of flow velocity and that the effective numerical aperture of the optical objective in the sample arm determines the slope of this dependence. The Doppler bandwidth permits accurate measurement of flow velocity without the need for precise determination of flow direction when the Doppler flow angle is within +/-15degrees perpendicular to the probing beam. Such an approach extends the dynamic range of flow velocity measurements obtained with the phase-resolved F-OCT. (C) 2002 Optical Society of America.
引用
收藏
页码:409 / 411
页数:3
相关论文
共 8 条
[1]
Noninvasive imaging of in vivo blood flow velocity using optical Doppler tomography
[J].
Chen, ZP
;
Milner, TE
;
Srinivas, S
;
Wang, XJ
;
Malekafzali, A
;
vanGemert, MJC
;
Nelson, JS
.
OPTICS LETTERS,
1997, 22 (14)
:1119-1121

Chen, ZP
论文数: 0 引用数: 0
h-index: 0
机构: Beckman Laser Inst. and Med. Clinic, University of California, Irvine, Irvine

Milner, TE
论文数: 0 引用数: 0
h-index: 0
机构: Beckman Laser Inst. and Med. Clinic, University of California, Irvine, Irvine

Srinivas, S
论文数: 0 引用数: 0
h-index: 0
机构: Beckman Laser Inst. and Med. Clinic, University of California, Irvine, Irvine

Wang, XJ
论文数: 0 引用数: 0
h-index: 0
机构: Beckman Laser Inst. and Med. Clinic, University of California, Irvine, Irvine

Malekafzali, A
论文数: 0 引用数: 0
h-index: 0
机构: Beckman Laser Inst. and Med. Clinic, University of California, Irvine, Irvine

vanGemert, MJC
论文数: 0 引用数: 0
h-index: 0
机构: Beckman Laser Inst. and Med. Clinic, University of California, Irvine, Irvine

Nelson, JS
论文数: 0 引用数: 0
h-index: 0
机构: Beckman Laser Inst. and Med. Clinic, University of California, Irvine, Irvine
[2]
Optical Doppler tomographic imaging of fluid flow velocity in highly scattering media
[J].
Chen, ZP
;
Milner, TE
;
Dave, D
;
Nelson, JS
.
OPTICS LETTERS,
1997, 22 (01)
:64-66

Chen, ZP
论文数: 0 引用数: 0
h-index: 0
机构: Beckman Laser Inst. and Med. Clinic, University of California, Irvine, Irvine

Milner, TE
论文数: 0 引用数: 0
h-index: 0
机构: Beckman Laser Inst. and Med. Clinic, University of California, Irvine, Irvine

Dave, D
论文数: 0 引用数: 0
h-index: 0
机构: Beckman Laser Inst. and Med. Clinic, University of California, Irvine, Irvine

Nelson, JS
论文数: 0 引用数: 0
h-index: 0
机构: Beckman Laser Inst. and Med. Clinic, University of California, Irvine, Irvine
[3]
OPTICAL COHERENCE TOMOGRAPHY
[J].
HUANG, D
;
SWANSON, EA
;
LIN, CP
;
SCHUMAN, JS
;
STINSON, WG
;
CHANG, W
;
HEE, MR
;
FLOTTE, T
;
GREGORY, K
;
PULIAFITO, CA
;
FUJIMOTO, JG
.
SCIENCE,
1991, 254 (5035)
:1178-1181

HUANG, D
论文数: 0 引用数: 0
h-index: 0
机构: MIT,DEPT ELECT ENGN & COMP SCI,CAMBRIDGE,MA 02139

SWANSON, EA
论文数: 0 引用数: 0
h-index: 0
机构: MIT,DEPT ELECT ENGN & COMP SCI,CAMBRIDGE,MA 02139

LIN, CP
论文数: 0 引用数: 0
h-index: 0
机构: MIT,DEPT ELECT ENGN & COMP SCI,CAMBRIDGE,MA 02139

SCHUMAN, JS
论文数: 0 引用数: 0
h-index: 0
机构: MIT,DEPT ELECT ENGN & COMP SCI,CAMBRIDGE,MA 02139

STINSON, WG
论文数: 0 引用数: 0
h-index: 0
机构: MIT,DEPT ELECT ENGN & COMP SCI,CAMBRIDGE,MA 02139

CHANG, W
论文数: 0 引用数: 0
h-index: 0
机构: MIT,DEPT ELECT ENGN & COMP SCI,CAMBRIDGE,MA 02139

HEE, MR
论文数: 0 引用数: 0
h-index: 0
机构: MIT,DEPT ELECT ENGN & COMP SCI,CAMBRIDGE,MA 02139

FLOTTE, T
论文数: 0 引用数: 0
h-index: 0
机构: MIT,DEPT ELECT ENGN & COMP SCI,CAMBRIDGE,MA 02139

GREGORY, K
论文数: 0 引用数: 0
h-index: 0
机构: MIT,DEPT ELECT ENGN & COMP SCI,CAMBRIDGE,MA 02139

PULIAFITO, CA
论文数: 0 引用数: 0
h-index: 0
机构: MIT,DEPT ELECT ENGN & COMP SCI,CAMBRIDGE,MA 02139

FUJIMOTO, JG
论文数: 0 引用数: 0
h-index: 0
机构: MIT,DEPT ELECT ENGN & COMP SCI,CAMBRIDGE,MA 02139
[4]
Velocity-estimation accuracy and frame-rate limitations in color Doppler optical coherence tomography
[J].
Kulkarni, MD
;
van Leeuwen, TG
;
Yazdanfar, S
;
Izatt, JA
.
OPTICS LETTERS,
1998, 23 (13)
:1057-1059

Kulkarni, MD
论文数: 0 引用数: 0
h-index: 0
机构:
Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA

van Leeuwen, TG
论文数: 0 引用数: 0
h-index: 0
机构: Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA

Yazdanfar, S
论文数: 0 引用数: 0
h-index: 0
机构: Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA

Izatt, JA
论文数: 0 引用数: 0
h-index: 0
机构: Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[5]
In vivo video rate optical coherence tomography
[J].
Rollins, AM
;
Kulkarni, MD
;
Yazdanfar, S
;
Ung-arunyawee, R
;
Izatt, JA
.
OPTICS EXPRESS,
1998, 3 (06)
:219-229

Rollins, AM
论文数: 0 引用数: 0
h-index: 0
机构:
Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA

Kulkarni, MD
论文数: 0 引用数: 0
h-index: 0
机构: Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA

Yazdanfar, S
论文数: 0 引用数: 0
h-index: 0
机构: Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA

Ung-arunyawee, R
论文数: 0 引用数: 0
h-index: 0
机构: Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA

Izatt, JA
论文数: 0 引用数: 0
h-index: 0
机构: Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[6]
High-speed phase- and group-delay scanning with a grating-based phase control delay line
[J].
Tearney, GJ
;
Bouma, BE
;
Fujimoto, JG
.
OPTICS LETTERS,
1997, 22 (23)
:1811-1813

Tearney, GJ
论文数: 0 引用数: 0
h-index: 0
机构: Dept. of Elec. Eng. and Comp. Sci., Research Laboratory of Electronics, Massachusetts Inst. of Technology, Cambridge

Bouma, BE
论文数: 0 引用数: 0
h-index: 0
机构: Dept. of Elec. Eng. and Comp. Sci., Research Laboratory of Electronics, Massachusetts Inst. of Technology, Cambridge

Fujimoto, JG
论文数: 0 引用数: 0
h-index: 0
机构: Dept. of Elec. Eng. and Comp. Sci., Research Laboratory of Electronics, Massachusetts Inst. of Technology, Cambridge
[7]
Doppler standard deviation imaging for clinical monitoring of in vivo human skin blood flow
[J].
Zhao, YH
;
Chen, ZP
;
Saxer, C
;
Shen, QM
;
Xiang, SH
;
de Boer, JF
;
Nelson, JS
.
OPTICS LETTERS,
2000, 25 (18)
:1358-1360

Zhao, YH
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA

Chen, ZP
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA

Saxer, C
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA

Shen, QM
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA

Xiang, SH
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA

de Boer, JF
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA

Nelson, JS
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA
[8]
Phase-resolved optical coherence tomography and optical Doppler tomography for imaging blood flow in human skin with fast scanning speed and high velocity sensitivity
[J].
Zhao, YH
;
Chen, ZP
;
Saxer, C
;
Xiang, SH
;
de Boer, JF
;
Nelson, JS
.
OPTICS LETTERS,
2000, 25 (02)
:114-116

Zhao, YH
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA

Chen, ZP
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA

Saxer, C
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA

Xiang, SH
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA

de Boer, JF
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA

Nelson, JS
论文数: 0 引用数: 0
h-index: 0
机构:
Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA