共 32 条
Rapid and simple G-quadruplex DNA aptasensor with guanine chemiluminescence detection
被引:44
作者:
Cho, Sandy
[1
]
Park, Lucienne
[1
,2
]
Chong, Richard
[1
]
Kim, Young Teck
[3
]
Lee, Ji Hoon
[1
]
机构:
[1] Luminescent MD LLC, Hagerstown, MD 21742 USA
[2] Univ Maryland, Dept Biol, College Pk, MD 20742 USA
[3] Virginia Polytech Inst & State Univ, Dept Wood Sci & Forest Prod, Blacksburg, VA 24061 USA
关键词:
Guanine chemiluminescence;
G-quaduplex DNA Aptasensor;
Chemiluminescence resonance energy transfer (CRET);
Thrombin;
3,4,5-trimethoxylphenylglyoxal hydrate (TMPG);
Magnetic Fe3O4 graphene oxide;
THROMBIN-BINDING APTAMER;
PEROXYOXALATE CHEMILUMINESCENCE;
LABEL-FREE;
POTASSIUM-ION;
DNAZYME;
ADENOSINE;
SELECTION;
REAGENT;
AMPLIFICATION;
PEROXIDASE;
D O I:
10.1016/j.bios.2013.09.017
中图分类号:
Q6 [生物物理学];
学科分类号:
071011 ;
摘要:
Cost-effective and sensitive aptasensor with guanine chemiluminescence detection capable of simply quantifying thrombin in human serum was developed using thrombin aptamer (TBA), one of the G-quadruplex DNA aptamers, without expensive nanoparticles and complicated procedures. Guanines of G-quadruplex TBA-conjugated carboxyfluorescein (6-FAM) bound with thrombin do not react with 3,4,5-trimethoxylphenylglyoxal (TMPG) in the presence of tetra-n-propylammonium hydroxide (TPA), whereas guanines of free TBA- and TBA-conjugated 6-FAM immobilized on the surface of graphene oxide rapidly react with TMPG to emit light. Thus, guanine chemiluminescence in 5% human serum with thrombin was lower than that without thrombin when TBA-conjugated 6-FAM was added in two samples and incubated for 20 min. In other words, the brightness of guanine chemiluminescence was quenched due to the formation of G-quadruplex TBA-conjugated 6-FAM bound with thrombin in a sample. High-energy intermediate, capable of emitting dim light by itself, formed from the reaction between guanines of TBA and TMPG in the presence of TPA, transfers energy to 6-FAM to emit bright light based on the principle of chemiluminescence energy transfer (CRET). G-quadruplex TBA aptasensor devised using the rapid interaction between TBA-conjugated 6-FAM and thrombin quantified trace levels of thrombin without complicated procedures. The limit of detection (LOD=background +3 x standard deviation) of G-quadruplex TBA aptasensor with good linear calibration curve, accuracy, precision, and recovery was as low as 12.3 nM in 5% human serum. Using the technology reported in this research, we expect that various types of G-quadruplex DNA aptasensors capable of specifically sensing a target molecule such as ATP, HIV, ochratoxin, potassium ions, and thrombin can be developed. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:310 / 316
页数:7
相关论文