Minimally invasive Cardioverter defibrillator implantation for children: An animal model and pediatric case report

被引:66
作者
Berul, CI
Triedman, JK
Forbess, J
Bevilacqua, LM
Alexander, ME
Dahlby, D
Gilkerson, JO
Walsh, EP
机构
[1] Harvard Univ, Childrens Hosp, Dept Cardiol, Sch Med, Boston, MA 02115 USA
[2] Harvard Univ, Childrens Hosp, Dept Cardiac Surg, Sch Med, Boston, MA 02115 USA
[3] Guidant Corp, St Paul, MN USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2001年 / 24卷 / 12期
关键词
cardioverter defibrillator; pediatrics; defibrillation; tachyarrhythmias; animal models;
D O I
10.1046/j.1460-9592.2001.01789.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The smaller venous capacitance in infants and small children may hamper transvenous ICD lead implantation, and epicardial approaches require thoracotomy and have associated complications. The study evaluated the feasibility and performance of subcutaneous arrays and active can ICDs without transvenous shocking coils or epicardial patches. An immature and mature pig were anesthetized and ventilated. A pacing lead was inserted in the right ventricle for fibrillation induction and rate sensing. Subcutaneous arrays were positioned in the right and left chest walls. An ICD emulator was placed in abdominal and prepectoral pockets. Fluoroscopic images were acquired for each electrical vector configuration (array --> can, can --> array, array --> array, array + array --> can). Ventricular fibrillation was induced and DFT testing performed. Defibrillation was achieved in all ten trials in the immature piglet, with DFT less than or equal to 9 J, regardless of vector configuration, Using a single subcutaneous array and active can, the shock impedance ranged from 28-36 ohms. With two arrays, shocking impedance fell to 15-22 ohms. In the adult pig, defibrillation was not accomplished with maximum energy of 40 J, using all vector configurations. Using data garnered from these experiments, this technique was then successfully performed in a 2-year-old child with VT and repaired congenital heart disease, needing an ICD. This study demonstrates the feasibility of leadless ICD implantation in an immature animal and successful implementation in a small child. A single subcutaneous array and active can resulted in excellent implant characteristics and DFTs with a minimally invasive approach. Defibrillation was not possible in a larger animal, possibly due to maximal available energy. This may be of value for small children requiring ICD implantation.
引用
收藏
页码:1789 / 1794
页数:6
相关论文
共 17 条
[1]   Value of programmed ventricular stimulation in patients with congenital heart disease [J].
Alexander, ME ;
Walsh, EP ;
Saul, JP ;
Epstein, MR ;
Triedman, JK .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1999, 10 (08) :1033-1044
[2]  
BERUL CI, 2001, CARDIAC ARRHYTHMIAS, P319
[3]   High failure rate for an epicardial implantable cardioverter-defibrillator lead: Implications for long-term follow-up of patients with an implantable cardioverter-defibrillator [J].
Brady, PA ;
Friedman, PA ;
Trusty, JM ;
Grice, S ;
Hammill, SC ;
Stanton, MS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (03) :616-622
[4]   Use of a single coil transvenous electrode with an abdominally placed implantable cardioverter defibrillator in children [J].
Fischbach, PS ;
Law, IH ;
Dick, M ;
Leroy, S ;
Mosca, RS ;
Serwer, GA .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (05) :884-887
[5]   Implantable defibrillators in children: From whence to shock [J].
Friedman, RA ;
Garson, A .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2001, 12 (03) :361-362
[6]   THE LONG QT SYNDROME IN CHILDREN - AN INTERNATIONAL STUDY OF 287 PATIENTS [J].
GARSON, A ;
DICK, M ;
FOURNIER, A ;
GILLETTE, PC ;
HAMILTON, R ;
KUGLER, JD ;
VANHARE, GF ;
VETTER, V ;
VICK, GW .
CIRCULATION, 1993, 87 (06) :1866-1872
[7]   Comparison of single- and dual-coil active pectoral defibrillation lead systems [J].
Gold, MR ;
Olsovsky, MR ;
Pelini, MA ;
Peters, RW ;
Shorofsky, SR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (06) :1391-1394
[8]   Nonthoracotomy implantable cardioverter defibrillator placement in children:: Use of subcutaneous array leads and abdominally placed implantable cardioverter defibrillators in children [J].
Gradaus, R ;
Hammel, D ;
Kotthoff, S ;
Böcker, D .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2001, 12 (03) :356-360
[9]   Five-year experience with implantable defibrillators in children [J].
Hamilton, RM ;
Dorian, P ;
Gow, RM ;
Williams, WG .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 77 (07) :524-&
[10]   THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR IN YOUNG-PATIENTS [J].
KRON, J ;
OLIVER, RP ;
NORSTED, S ;
SILKA, MJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (04) :896-902