Comparison of single- and dual-coil active pectoral defibrillation lead systems

被引:65
作者
Gold, MR [1 ]
Olsovsky, MR [1 ]
Pelini, MA [1 ]
Peters, RW [1 ]
Shorofsky, SR [1 ]
机构
[1] Univ Maryland, Med Syst, Sch Med, Dept Med,Div Cardiol, Baltimore, MD 21201 USA
关键词
D O I
10.1016/S0735-1097(98)00103-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. The purpose of this study was to compare defibrillation thresholds with lead systems consisting of an active left pectoral electrode and either single or dual transvenous coils. Background. Lead systems that include an active pectoral pulse generator reduce defibrillation thresholds and permit transvenous defibrillation in nearly all patients. A further improvement in defibrillation efficacy is desirable to allow for smaller pulse generators with a reduced maximal output. Methods. This prospective study was performed in 50 consecutive patients. Each patient was evaluated with two lead configurations with the order of testing randomized. Shocks were delivered between the right ventricular coil and either an active can alone (single coil) or an active can with the proximal atrial coil (dual coil). The right ventricular coil was the cathode for the first phase of the biphasic defibrillation waveform. Results. Delivered energy at the defibrillation threshold was 10.1 +/- 5.0 J for the single-coil configuration and 8.7 +/- 4.0 J for the dual-coil configuration (p < 0.02). Moreover, 98% of patients had low (less than or equal to 15 J) thresholds with the dual-coil lead system, compared with 88% of patients with the single-coil configuration (p = 0.05). Leading edge voltage (p < 0.001) and shock impedance (p < 0.001) were also decreased with the dual coil configuration, although peak current was increased (p < 0.001). Conclusions. A dual-coil, active pectoral lead system reduces defibrillation energy requirements compared with a single-coil, unipolar configuration. (C) 1998 by the American College of Cardiology.
引用
收藏
页码:1391 / 1394
页数:4
相关论文
共 28 条
[1]   A SIMPLIFIED, SINGLE-LEAD UNIPOLAR TRANSVENOUS CARDIOVERSION-DEFIBRILLATION SYSTEM [J].
BARDY, GH ;
JOHNSON, G ;
POOLE, JE ;
DOLACK, GL ;
KUDENCHUK, PJ ;
KELSO, D ;
MITCHELL, R ;
MEHRA, R ;
HOFER, B .
CIRCULATION, 1993, 88 (02) :543-547
[2]   ENSURING AUTOMATIC DETECTION OF VENTRICULAR-FIBRILLATION [J].
BARDY, GH .
CIRCULATION, 1992, 86 (05) :1634-1635
[3]   ELECTRODE SYSTEM INFLUENCE ON BIPHASIC WAVE-FORM DEFIBRILLATION EFFICACY IN HUMANS [J].
BARDY, GH ;
TROUTMAN, C ;
JOHNSON, G ;
MEHRA, R ;
POOLE, JE ;
DOLACK, GL ;
KUDENCHUK, PJ ;
GARTMAN, DM .
CIRCULATION, 1991, 84 (02) :665-671
[4]   PROSPECTIVE, RANDOMIZED COMPARISON IN HUMANS OF A UNIPOLAR DEFIBRILLATION SYSTEM WITH THAT USING AN ADDITIONAL SUPERIOR VENA-CAVA ELECTRODE [J].
BARDY, GH ;
DOLACK, GL ;
KUDENCHUK, PJ ;
POOLE, JE ;
MEHRA, R ;
JOHNSON, G .
CIRCULATION, 1994, 89 (03) :1090-1093
[5]   Complications associated with pectoral cardioverter-defibrillator implantation: Comparison of subcutaneous and submuscular approaches [J].
Gold, MR ;
Peters, RW ;
Johnson, JW ;
Shorofsky, SR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (05) :1278-1282
[6]   Biphasic waveforms prevent the chronic rise of defibrillation thresholds with a transvenous lead system [J].
Gold, MR ;
Kavesh, NG ;
Peters, RW ;
Shorofsky, SR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (01) :233-236
[7]   Transvenous defibrillation lead systems [J].
Gold, MR ;
Shorofsky, SR .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1996, 7 (06) :570-580
[8]   Effects of an active pectoral-pulse generator shell on defibrillation efficacy with a transvenous lead system [J].
Gold, MR ;
Foster, AH ;
Shorofsky, SR .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 (05) :540-543
[9]   A multicenter, randomized trial comparing an active can implantable defibrillator with a passive can system [J].
Haffajee, C ;
Martin, D ;
Bhandari, A ;
Bardy, GH ;
DeSouza, C ;
Kuehlkamp, V ;
Church, T .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (01) :215-219
[10]   CURRENT CONCEPTS FOR SELECTING THE LOCATION, SIZE AND SHAPE OF DEFIBRILLATION ELECTRODES [J].
IDEKER, RE ;
WOLF, PD ;
ALFERNESS, C ;
KRASSOWSKA, W ;
SMITH, WM .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (02) :227-&