Simultaneous quantitative assessment of cerebral physiology using respiratory-calibrated MRI and near-infrared spectroscopy in healthy adults

被引:42
作者
Alderliesten, T. [1 ]
De Vis, J. B. [2 ]
Lemmers, P. M. A. [1 ]
van Bel, F. [1 ]
Benders, M. J. N. L. [1 ]
Hendrikse, J. [2 ]
Petersen, E. T. [2 ]
机构
[1] Univ Med Ctr Utrecht, Wilhelmina Childrens Hosp, Dept Neonatol, NL-3508 AB Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Dept Radiol, NL-3508 GA Utrecht, Netherlands
关键词
Near-Infrared Spectroscopy; fMRI; fNIRS; Respiratory-calibrated MRI; Adult; Brain; ASL; BLOOD-VOLUME; BRAIN ACTIVATION; BOLD SIGNAL; OXYGENATION CHANGES; ABSORPTION-SPECTRA; FUNCTIONAL MRI; CARBON-DIOXIDE; FOCAL CHANGES; NIRS-FMRI; TISSUE;
D O I
10.1016/j.neuroimage.2013.07.015
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: Functional near-infrared spectroscopy (fNIRS) and functional MRI (fMRI) are non-invasive techniques used to relate activity in different brain regions to certain tasks. Respiratory calibration of the blood oxygen level dependent (BOLD) signal, and combined fNIRS-fMRI approaches have been used to quantify physiological subcomponents giving rise to the BOLD signal. A comparison of absolute oxygen metabolism parameters between MRI and NIRS, using spatially resolved (SRS) NIRS and respiratory calibrated MRI, could yield additional insight in the physiology underlying activation. Materials and methods: Changes in the BOLD signal, cerebral blood flow (CBF), and oxygen saturation (SO2) were derived from a single MRI sequence during a respiratory challenge in healthy volunteers. These changes were compared to SO2 obtained by a single probe SRS NIRS setup. In addition, concentration changes in oxygenated (O(2)Hb), deoxygenated (HHb), and total haemoglobin (tHb), obtained by NIRS, were compared to the parameters obtained by MRI. Results: NIRS SO2 correlated with end-tidal CO2 (0.83, p < 0.0001), the BOLD signal (0.82, p < 0.0001), CBF (0.85, p < 0.0001), and also MRI SO2 (0.82, p < 0.0001). The BOLD signal correlated with NIBS HHb (-0.76, p < 0.0001), O(2)Hb (0.41, p = 0.001), and tHb (r = 032, p = 0.01). Conclusions: Good correlations show that changes in cerebral physiology, following a respiratory challenge, go hand in hand with changes in the BOLD signal, CBF, O(2)Hb, HHb, NIRS SO2, and MRI SO2. Out of all NIBS derived parameters, the SO2 showed the best correlation with the BOLD signal. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:255 / 263
页数:9
相关论文
共 77 条
[61]   Prospective targeting and control of end-tidal CO2 and O2 concentrations [J].
Slessarev, Marat ;
Han, Jay ;
Mardimae, Alexandra ;
Prisman, Eitan ;
Preiss, David ;
Volgyesi, George ;
Ansel, Cliff ;
Duffin, James ;
Fisher, Joseph A. .
JOURNAL OF PHYSIOLOGY-LONDON, 2007, 581 (03) :1207-1219
[62]   Illuminating the BOLD signal: combined fMRI-fNIRS studies [J].
Steinbrink, Jens ;
Villringer, Amo ;
Kempf, Florian ;
Haux, Daniel ;
Boden, Stefanie ;
Obrig, Hellmuth .
MAGNETIC RESONANCE IMAGING, 2006, 24 (04) :495-505
[63]   A quantitative comparison of simultaneous BOLD fMRI and NIRS recordings during functional brain activation [J].
Strangman, G ;
Culver, JP ;
Thompson, JH ;
Boas, DA .
NEUROIMAGE, 2002, 17 (02) :719-731
[64]   Factors affecting the accuracy of near-infrared spectroscopy concentration calculations for focal changes in oxygenation parameters [J].
Strangman, G ;
Franceschini, MA ;
Boas, DA .
NEUROIMAGE, 2003, 18 (04) :865-879
[65]   A tissue oxygenation monitor using NIR spatially resolved spectroscopy [J].
Suzuki, S ;
Takasaki, S ;
Ozaki, T ;
Kobayashi, Y .
OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE III, PROCEEDINGS OF, 1999, 3597 :582-592
[66]  
Tachtsidis I, 2006, ADV EXP MED BIOL, V578, P237
[67]   Spatiotemporal properties of cortical haemodynamic response to auditory stimuli in sleeping infants revealed by multi-channel near-infrared spectroscopy [J].
Taga, Gentaro ;
Watanabe, Hama ;
Homae, Fumitaka .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2011, 369 (1955) :4495-4511
[68]   Investigation of human brain hemodynamics by simultaneous near-infrared spectroscopy and functional magnetic resonance imaging [J].
Toronov, V ;
Webb, A ;
Choi, JH ;
Wolf, M ;
Michalos, A ;
Gratton, E ;
Hueber, D .
MEDICAL PHYSICS, 2001, 28 (04) :521-527
[69]   Monitoring Neonatal Regional Cerebral Oxygen Saturation in Clinical Practice: Value and Pitfalls [J].
van Bel, Frank ;
Lemmers, Petra ;
Naulaers, Gunnar .
NEONATOLOGY, 2008, 94 (04) :237-244
[70]   The microvascular system of the striate and extrastriate visual cortex of the macaque [J].
Weber, Bruno ;
Keller, Anna Lena ;
Reichold, Johannes ;
Logothetis, Nikos K. .
CEREBRAL CORTEX, 2008, 18 (10) :2318-2330