Volumetric image-guidance: Does routine usage prompt adaptive re-planning? An institutional review

被引:30
作者
Tanyi, James A. [1 ]
Fuss, Martin H. [1 ]
机构
[1] Oregon Hlth & Sci Univ, Dept Radiat Med, Portland, OR 97239 USA
关键词
D O I
10.1080/02841860802279741
中图分类号
R73 [肿瘤学];
学科分类号
100214 [肿瘤学];
摘要
Purpose. To investigate how the use of volumetric image-guidance using an on-board cone-beam computed tomography (CBCT) system impacts on the frequency of adaptive re-planning. Material and methods. Treatment courses of 146 patients who have undergone a course of external beam radiation therapy (EBRT) using volumetric CBCT image-guidance were analyzed. Target locations included the brain, head and neck, chest, abdomen, as well as prostate and non-prostate pelvis. The majority of patients (57.5%) were treated with hypo-fractionated treatment regimens (three to 15 fraction courses). The frequency of image-guidance ranged from daily (87.7%) to weekly or twice weekly. The underlying medical necessity for adaptive re-planning as well as frequency and consequences of plan adaptation to dose-volume parameters was assessed. Results. Radiation plans of 34 patients (23.3%) were adapted at least once (up to six time) during their course of EBRT as a result of image-guidance CBCT review. Most common causes for adaptive planning were: tumor change (mostly shrinkage: 10 patients; four patients more than one re-plan), change in abdominal girth (systematic change in hollow organ filling; n=7, two patients more than one re-plan), weight loss (n=5), and systematic target setup deviation from simulation (n=5). Adaptive re-plan was required mostly for conventionally fractionated courses; only 5 patient plans undergoing hypo-fractionated treatment were adjusted. In over 91% of adapted plans, the dose-volume parameters did deviate from the prescribed plan parameters by more than 5% for at least 10% of the target volume, or organs-at-risk in close proximity to the target volume. Discussion. Routine use of volumetric image-guidance has in our practice increased the demand for adaptive re-planning. Volumetric CBCT image-guidance provides sufficient imaging information to reliably predict the need for dose adjustment. In the vast majority of cases evaluated, the initial and adapted dose-volume parameters differed to a degree that was considered clinically significant.
引用
收藏
页码:1444 / 1453
页数:10
相关论文
共 19 条
[1]
Quantification of volumetric and geometric changes occurring during fractionated radiotherapy for head-and-neck cancer using an integrated CT/linear accelerator system [J].
Barker, JL ;
Garden, AS ;
Ang, KK ;
O'Daniel, JC ;
Wang, H ;
Court, LE ;
Morrison, WH ;
Rosenthal, DI ;
Chao, KSC ;
Tucker, SL ;
Mohan, R ;
Dong, L .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (04) :960-970
[2]
A study on adaptive IMRT treatment planning using kV cone-beam CT [J].
Ding, George X. ;
Duggan, Dennis M. ;
Coffey, Charles W. ;
Deeley, Matthew ;
Hallahan, Dennis E. ;
Cmelak, Anthony ;
Malcolm, Arnold .
RADIOTHERAPY AND ONCOLOGY, 2007, 85 (01) :116-125
[3]
Dose, volume, and function relationships in parotid salivary glands following conformal and intensity-modulated irradiation of head and neck cancer [J].
Eisbruch, A ;
Ten Haken, RK ;
Kim, HM ;
Marsh, LH ;
Ship, JA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (03) :577-587
[4]
Portal imaging to assess set-up errors, tumor motion and tumor shrinkage during conformal radiotherapy of non-small cell lung cancer [J].
Erridge, SC ;
Seppenwoolde, Y ;
Muller, SH ;
van Herk, M ;
De Jaeger, K ;
Belderbos, JSA ;
Boersma, LJ ;
Lebesque, JV .
RADIOTHERAPY AND ONCOLOGY, 2003, 66 (01) :75-85
[5]
The utility of megavoltage computed tomography images from a helical tomotherapy system for setup verification purposes [J].
Forrest, LJ ;
Mackie, TR ;
Ruchala, K ;
Turek, M ;
Kapatoes, J ;
Jaradat, H ;
Hui, S ;
Balog, J ;
Vail, DM ;
Mehta, MP .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (05) :1639-1644
[6]
Is adaptive treatment planning required for stereotactic radiotherapy of stage I non-small-cell lung cancer? [J].
Haasbeek, Cornelis J. A. ;
Lagerwaard, Frank J. ;
Cuijpers, Johan P. ;
Slotman, Ben J. ;
Senan, Suresh .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (05) :1370-1374
[7]
Actual dose variation of parotid glands and spinal cord for nasopharyngeal cancer patients during radiotherapy [J].
Han, Chunhui ;
Chen, Yi-Jen ;
Liu, An ;
Schultheiss, Timothy E. ;
Wong, Jeffrey Y. C. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (04) :1256-1262
[8]
Repeat CT imaging and replanning during the course of IMRT for head-and-neck cancer [J].
Hansen, EK ;
Bucci, MK ;
Quivey, JM ;
Weinberg, V ;
Xia, P .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (02) :355-362
[9]
Serial megavoltage CT imaging during external beam radiotherapy for non-small-cell lung cancer: Observations on tumor regression during treatment [J].
Kupelian, PA ;
Ramsey, C ;
Meeks, SL ;
Willoughby, TR ;
Forbes, A ;
Wagner, TH ;
Langen, KM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (04) :1024-1028
[10]
Initial experience with megavoltage (MV) CT guidance for daily prostate alignments [J].
Langen, KM ;
Zhang, YS ;
Andrews, RD ;
Hurley, ME ;
Meeks, SL ;
Poole, DO ;
Willoughby, TR ;
Kupelian, PA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (05) :1517-1524