摘要
Simultaneous determination of Fe/S and Mn/S ratios on transient signals was performed by size exclusion chromatography, hyphenated to inductively coupled plasma mass spectrometry with dynamic reaction cell technology (SEC-ICP-DRCMS), in order to characterize metalloprotein samples by their metal/sulfur ratio. Oxygen was used as the cell gas. The method eliminates the effect of polyatomic isobaric interferences at m/z = 32 by detecting sulfur as the product oxide ion (SO)-S-32-O-16 which is less interfered. Using the same reaction gas conditions, Fe and Mn were measured at m/z 54, 56 and 55, respectively. SEC-ICP-DRCMS measurements (injection volume 20 muL, SEC flow 300 muL min(-1)) resulted in excellent limits of detection (LOD). 4.3, 0.4, 2 and 0.6 ng g(-1) were assessed for (SO)-S-32-O-16, Mn-55, Fe-54 and Fe-56, respectively. Reference measurements were carried out by size exclusion chromatography inductively coupled plasma sector field mass spectrometry (SEC-ICP-SFMS), setting the mass resolution at 4500. LODs of 14, 0.5 and 0.4 ng g(-1) were obtained for S-32, Mn-55 and Fe-56, respectively. The metal/sulfur ratios of 5 commercially available metalloproteins were determined (myoglobin, haemoglobin, cytochrom c, arginase and Mn superoxide dismutase from E coli). Two proteins were characterized after in-house heterologous expression in a host organism (Mn superoxide dismutase from Anabaena PCC 7120, catalase-peroxidase from Synechocystis PCC 6803). Different calibrants (i.e., Fe3+, Mn2+, SO42-, methionine, myoglobin) for the assessment of inter-elemental ratios have been employed. It was found that calibration using metalloprotein myoglobin is preferable to inorganic standards in terms of uncertainty of measurement. However, all metal/sulfur ratios of the investigated proteins obtained by the different methods agreed within their total combined uncertainty.
引用
收藏
页码:74 / 79
页数:6
相关论文
共 16 条
[1]  
ATZHOFER W, 2002, J MOL BIOCH, V321, P479
[2]   Detection of ultratrace phosphorus and sulfur by quadrupole ICPMS with dynamic reaction cell [J].
Bandura, DR ;
Baranov, VI ;
Tanner, SD .
ANALYTICAL CHEMISTRY, 2002, 74 (07) :1497-1502
[3]  
EURACHEM, 2000, QUANT UNC AN MEAS
[4]   Multielement trace-element speciation in metal- biomolecules by chromatography coupled with ICP-MS [J].
Ferrarello, CN ;
de la Campa, MRF ;
Sanz-Medel, A .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (06) :412-421
[5]   Inductively coupled plasma time-of-flight mass spectrometry coupled to high-performance liquid chromatography for multi-elemental speciation analysis of metalloproteins in carp cytosols [J].
Infante, HG ;
Van Campenhout, K ;
Blust, R ;
Adams, FC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (02) :79-87
[6]  
ISO GUM, 1995, GUID EXPR UNC MEAS
[7]   Catalase-peroxidase from the cyanobacterium Synechocystis PCC 6803:: Cloning, overexpression in Escherichia coli, and kinetic characterization [J].
Jakopitsch, C ;
Rüker, F ;
Regelsberger, G ;
Dockal, M ;
Peschek, GA ;
Obinger, C .
BIOLOGICAL CHEMISTRY, 1999, 380 (09) :1087-1096
[9]   Determination of sulfur and selected trace elements in metallothionein-like proteins using capillary electrophoresis hyphenated to inductively coupled plasma mass spectrometry with an octopole reaction cell [J].
Pröfrock, D ;
Leonhard, P ;
Prange, A .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (01) :132-139
[10]   Inductively coupled plasma mass spectrometric detection for chromatography and capillary electrophoresis [J].
Sutton, K ;
Sutton, RMC ;
Caruso, JA .
JOURNAL OF CHROMATOGRAPHY A, 1997, 789 (1-2) :85-126