A Randomized comparison of the value of additional stenting after optimal balloon Angioplasty for long coronary lesions - Final results of the additional value of NIR Stents for treatment of long coronary lesions (ADVANCE) study

被引:64
作者
Serruys, PW [1 ]
Foley, DP [1 ]
Suttorp, MJ [1 ]
Rensing, BJWM [1 ]
Suryapranata, H [1 ]
Materne, P [1 ]
van den Bos, A [1 ]
Benit, E [1 ]
Anzuini, A [1 ]
Rutsch, W [1 ]
Legrand, V [1 ]
Dawkins, K [1 ]
Cobaugh, M [1 ]
Bressers, M [1 ]
Backx, B [1 ]
Wijns, W [1 ]
Colombo, A [1 ]
机构
[1] Erasmus Univ, Dept Intervent Cardiol, Heart Ctr, NL-3015 GD Rotterdam, Netherlands
关键词
D O I
10.1016/S0735-1097(01)01760-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES We sought to investigate the clinical benefit of additional stent implantation after achieving an optimal result of balloon angioplasty (BA) in long coronary lesions (>20 mm). BACKGROUND Long coronary lesions are associated with increased early complications and late restenosis after BA. Stenting improves the early outcome, but stent restenosis is also related to both lesion length and stent length. METHODS A total of 437 patients with a single native lesion 20 to 50 mm in length were included and underwent BA, using long balloons matched to lesion length and vessel diameter (balloon/artery ratio 1.1) to achieve a diameter stenosis (DS) <30% by on-line quantitative coronary angiography (QCA). "Bail-out stenting" was performed for flow-limiting dissections or >50% DS. Patients in whom an optimal BA result was achieved were randomized to additional stenting (using NIR stents) or no stenting. The primary end point was freedom from major adverse cardiac events (MACE) at nine months, and core laboratory QCA was performed on serial angiograms. RESULTS Bailout stenting was necessary in 149 patients (34%) and was associated with a significantly increased risk of peri-procedural infarction (p < 0.02). Among the 288 randomized patients, the mean lesion length was 27 +/- 9 mm, and the vessel diameter was 2.78 +/- 0.52 mm. The procedural success rate was 90% for the 143 patients assigned to BA alone (control group), as compared with 93% in the 145 patients assigned to additional stenting (stent group), which resulted in a superior early minimal lumen diameter (0.54 mm, p < 0.001) and led to reduced angiographic restenosis ( 27% vs. 42%, p = 0.022). Freedom from MACE at nine months was 77% in both groups. CONCLUSIONS A strategy of provisional stenting for long coronary lesions led to bailout stenting in one-third of patients, with a threefold increase in peri-procedural infarction. Additional stenting yielded a lower angiographic restenosis rate, but no reduction in MACE at nine months. (C) 2002 by the American College of Cardiology.
引用
收藏
页码:393 / 399
页数:7
相关论文
共 27 条
[21]  
Serruys PW, 2000, CIRCULATION, V102, P2930
[22]   Heparin-coated Palmaz-Schatz stents in human coronary arteries - Early outcome of the Benestent-II pilot study [J].
Serruys, PW ;
Emanuelsson, H ;
vanderGiessen, W ;
Lunn, AC ;
Kiemeney, F ;
Macaya, C ;
Rutsch, W ;
Heyndrickx, G ;
Suryapranata, H ;
Legrand, V ;
Goy, JJ ;
Materne, P ;
Bonnier, H ;
Morice, MC ;
Fajadet, J ;
Belardi, J ;
Colombo, A ;
Garcia, E ;
Ruygrok, P ;
deJaegere, P ;
Morel, MA .
CIRCULATION, 1996, 93 (03) :412-422
[23]   A COMPARISON OF BALLOON-EXPANDABLE-STENT IMPLANTATION WITH BALLOON ANGIOPLASTY IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
SERRUYS, PW ;
DEJAEGERE, P ;
KIEMENEIJ, F ;
MACAYA, C ;
RUTSCH, W ;
HEYNDRICKX, G ;
EMANUELSSON, H ;
MARCO, J ;
LEGRAND, V ;
MATERNE, P ;
BELARDI, J ;
SIGWART, U ;
COLOMBO, A ;
GOY, JJ ;
VANDENHEUVEL, P ;
DELCAN, J ;
MOREL, MA .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :489-495
[24]   Minimal myocardial damage during coronary intervention is associated with impaired outcome [J].
Simoons, ML ;
van den Brand, M ;
Lincoff, N ;
Harrington, R ;
van der Wieken, R ;
Vahanian, A ;
Rutsch, W ;
Kootstra, J ;
Boersma, E ;
Califf, RM ;
Topol, E .
EUROPEAN HEART JOURNAL, 1999, 20 (15) :1112-1119
[25]  
Sousa JE, 2001, CIRCULATION, V103, P192
[26]   Improved procedural results of coronary angioplasty with intravascular ultrasound-guided balloon sizing - The CLOUT pilot trial [J].
Stone, GW ;
Hodgson, JM ;
StGoar, FG ;
Frey, A ;
Mudra, H ;
Sheehan, H ;
Linnemeier, TJ .
CIRCULATION, 1997, 95 (08) :2044-2052
[27]   Optimum percutaneous transluminal coronary angioplasty compared with routine stent strategy trial (OPUS-1): a randomised trial [J].
Weaver, WD ;
Reisman, MA ;
Griffin, JJ ;
Buller, CE ;
Leimgruber, PP ;
Henry, T ;
D'Haem, C ;
Clark, VL ;
Martin, JS ;
Cohen, DJ ;
Neil, N ;
Every, NR .
LANCET, 2000, 355 (9222) :2199-2203