Performance evaluation and life cycle cost analysis of earth to air heat exchanger integrated with adobe building for New Delhi composite climate

被引:100
作者
Chel, Arvind [1 ]
Tiwari, G. N. [1 ]
机构
[1] Indian Inst Technol, Ctr Energy Studies, New Delhi 110016, India
关键词
Vault roof; Adobe; EAHE; Energy saving; SEER; Carbon credit; LCC; THERMAL PERFORMANCE; INTERNAL SURFACES; PUMP SYSTEM; DOMED ROOFS; ENERGY; EMISSIONS;
D O I
10.1016/j.enbuild.2008.07.006
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper aims to develop thermal model of a vault roof building integrated with earth to air heat exchanger (EAHE). The building under consideration is made of brick vault and adobe (or mud) structures. The methodology adopted for developing thermal model of this building with six interconnected rooms is presented ill this paper. The energy balance equations were solved simultaneously Using fourth order Runge-Kutta numerical technique. The results from the thermal model were validated using experimental observed data. Experimental results showed that the room air temperature during winter was found 5-15 degrees C higher as compared to ambient air temperature while lower during Summer months. The results show that annual energy saving potential of the building before and after integration of EAHE were 4946 kWh/year and 10321 kWh/year respectively. The seasonal energy efficiency ratio (SEER) for EAHE was determined as 2-3. This considerable increase in annual energy savings potential of building due to EAHE leads to mitigration of CO2 emissions about 16 tons/year and the corresponding annual carbon credit of building was estimated as (sic) 340/year. The life cycle cost (LCC) analysis shows that the payback period is less than 2 years for the investment on EAHE system. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:56 / 66
页数:11
相关论文
共 22 条
[1]  
Algifri A.H., 1992, RENEW ENERG, V6, P597, DOI DOI 10.1016/0960-1481(92)90024-W
[2]   THERMAL PERFORMANCE OF ADOBE STRUCTURES WITH DOMED ROOFS AND MOIST INTERNAL SURFACES [J].
BAHADORI, MN ;
HAGHIGHAT, F .
SOLAR ENERGY, 1986, 36 (04) :365-375
[3]   PASSIVE COOLING IN HOT, ARID REGIONS IN DEVELOPING-COUNTRIES BY EMPLOYING DOMED ROOFS AND REDUCING THE TEMPERATURE OF INTERNAL SURFACES [J].
BAHADORI, MN ;
HAGHIGHAT, F .
BUILDING AND ENVIRONMENT, 1985, 20 (02) :103-113
[4]   Economical and environmental analysis of grid connected photovoltaic systems in Spain [J].
Bernal-Agustín, JL ;
Dufo-López, R .
RENEWABLE ENERGY, 2006, 31 (08) :1107-1128
[5]  
CHAPRA SC, 2002, NUMERICAL METHODS EN, P121
[6]   Energy conservation in honey storage building using Trombe wall [J].
Chel, Arvind ;
Nayak, J. K. ;
Kaushik, Geetanjali .
ENERGY AND BUILDINGS, 2008, 40 (09) :1643-1650
[7]   Heat transfer analysis of ground heat exchangers with inclined boreholes [J].
Cui, P ;
Yang, HX ;
Fang, ZH .
APPLIED THERMAL ENGINEERING, 2006, 26 (11-12) :1169-1175
[8]  
EBEN SMA, 1990, SOL WIND TECHNOL, V7, P407
[9]   A techno-economic comparison of ground-coupled and air-coupled heat pump system for space cooling [J].
Esen, Hikmet ;
Inalli, Mustafa ;
Esen, Mehmet .
BUILDING AND ENVIRONMENT, 2007, 42 (05) :1955-1965
[10]   Numerical and experimental analysis of a horizontal ground-coupled heat pump system [J].
Esen, Hikmet ;
Inalli, Mustafa ;
Esen, Mehmet .
BUILDING AND ENVIRONMENT, 2007, 42 (03) :1126-1134