Separation and detection of nitrophenols at capillary electrophoresis microchips with amperometric detection

被引:66
作者
Fischer, J
Barek, J
Wang, J [1 ]
机构
[1] Arizona State Univ, Dept Chem & Mat Engn, Biodesign Inst, Tempe, AZ 85287 USA
[2] Arizona State Univ, Dept Chem & Biochem, Biodesign Inst, Tempe, AZ 85287 USA
[3] Charles Univ, Dept Analyt Chem, UNESCO Lab Environm Electrochem, Prague 12843 2, Czech Republic
关键词
nitrophenols; capillary electrophoresis; micromachining; microchip; amperometric detection;
D O I
10.1002/elan.200503393
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A Miniaturized analytical system for the separation and amperometric detection of toxic nitrophenols, based on the Coupling of a micromachined capillary electrophoresis (CE) chip with a glassy carbon detector is described. This microsystem enables a rapid (120 s/sample) simultancous determination of five priority nitrophenolic Pollutants (2-nitrophenol, 3-nitrophenol, 4-nitrophenol, 2,4-dinitrophenol, and 2-methyl-4,6-dinitrophenol). These compounds can be detected down to the 1 x 10(-5) M level using a 15 mM phosphate buffer pH 7.2 (containing 1.3 mM alpha-cyclodextrin) as running solution on 77 mm long microchannel by applying a separation voltage of 3000 V and a negative potential of -0.7 V (vs. Ag/AgCl wire). Applicability to ground water samples was demonstrated.
引用
收藏
页码:195 / 199
页数:5
相关论文
共 23 条
[11]   Microfabrication of a planar absorbance and fluorescence cell for integrated capillary electrophoresis devices [J].
Liang, ZH ;
Chiem, N ;
Ocvirk, G ;
Tang, T ;
Fluri, K ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1996, 68 (06) :1040-1046
[12]   Separation of positional and structural isomers by cyclodextrin-mediated capillary zone electrophoresis [J].
Lucy, CA ;
Brown, R ;
Yeung, KKC .
JOURNAL OF CHROMATOGRAPHY A, 1996, 745 (1-2) :9-15
[13]   Occurrence and formation of nitrated phenols in and out of cloud [J].
Luttke, J ;
Scheer, V ;
Levsen, K ;
Wunsch, G ;
Cape, JN ;
Hargreaves, KJ ;
StoretonWest, RL ;
Acker, K ;
Wieprecht, W ;
Jones, B .
ATMOSPHERIC ENVIRONMENT, 1997, 31 (16) :2637-2648
[14]   CYCLIC VOLTAMMETRIC DETERMINATION OF ORTHO-NITROPHENOL IN THE PRESENCE OF PARA-NITROPHENOL BY ADDITION OF ALPHA-CYCLODEXTRIN [J].
MATSUE, T ;
FUJIHIRA, M ;
OSA, T .
ANALYTICAL CHEMISTRY, 1981, 53 (04) :722-723
[15]   Highly selective and efficient determination of US Environmental Protection Agency priority phenols employing solid-phase extraction and non-aqueous capillary electrophoresis [J].
Morales, S ;
Cela, R .
JOURNAL OF CHROMATOGRAPHY A, 2000, 896 (1-2) :95-104
[16]  
Staes E, 1999, ELECTROANAL, V11, P65, DOI 10.1002/(SICI)1521-4109(199901)11:1<65::AID-ELAN65>3.0.CO
[17]  
2-A
[18]  
US Environmental Protection Agency, 1989, Fed. Register, V52, P131
[19]   Microchip capillary electrophoresis coupled with a boron-doped diamond electrode-based electrochemical detector [J].
Wang, J ;
Chen, G ;
Chatrathi, MP ;
Fujishima, A ;
Tryk, DA ;
Shin, D .
ANALYTICAL CHEMISTRY, 2003, 75 (04) :935-939
[20]   Microchip device for cell lysis, multiplex PCR amplification, and electrophoretic sizing [J].
Waters, LC ;
Jacobson, SC ;
Kroutchinina, N ;
Khandurina, J ;
Foote, RS ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1998, 70 (01) :158-162