Optochemical nanosensors and subcellular applications in living cells

被引:49
作者
Clark, HA
Hoyer, M
Parus, S
Philbert, MA
Kopelman, M [1 ]
机构
[1] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Environm & Ind Hlth, Ann Arbor, MI 48109 USA
关键词
optodes; nanosensor; cellular probes; sensors;
D O I
10.1007/s006040050017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
What may be the smallest anthropogenic devices to date, spherical sensors (wireless and fiber-less) with radii as small as 10 nm have been produced. This class of optochemical PEBBLE (Probe Encapsulated By Biologically Localized Embedding) sensors covers a wide range of analytes (pH, calcium, oxygen and potassium included here) with excellent spatial, temporal and chemical resolution. Examples of such sensors for the monitoring of intracellular analytes are given. Methods, such as pico-injection, liposomal delivery and gene gun bombardment, are used to inject PEBBLE sensors into single cells. These PEBBLEs have caused minimal perturbation when delivered and operated inside single mammalian cells, such as human neuroblastoma, mouse oocytes or rat alveolar macrophage.
引用
收藏
页码:121 / 128
页数:8
相关论文
共 16 条
[1]   Characterization of photopolymerized decyl methacrylate as a membrane matrix for ion-selective electrodes [J].
Ambrose, TM ;
Meyerhoff, ME .
ELECTROANALYSIS, 1996, 8 (12) :1095-1100
[2]   SELECTIVITY OF ION-SENSITIVE BULK OPTODES [J].
BAKKER, E ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1805-1812
[3]   DETECTION LIMIT OF ION-SELECTIVE BULK OPTODES AND CORRESPONDING ELECTRODES [J].
BAKKER, E ;
WILLER, M ;
PRETSCH, E .
ANALYTICA CHIMICA ACTA, 1993, 282 (02) :265-271
[4]   Nitrite- and chloride-selective fluorescent nano-optodes and in in vitro application to rat conceptuses [J].
Barker, SLR ;
Thorsrud, BA ;
Kopelman, R .
ANALYTICAL CHEMISTRY, 1998, 70 (01) :100-104
[5]   Fiber-optic nitric oxide-selective biosensors and nanosensors [J].
Barker, SLR ;
Kopelman, R ;
Meyer, TE ;
Cusanovich, MA .
ANALYTICAL CHEMISTRY, 1998, 70 (05) :971-976
[6]   ENZYME IMMOBILIZATION IN NANOPARTICLES PRODUCED BY INVERSE MICROEMULSION POLYMERIZATION [J].
DAUBRESSE, C ;
GRANDFILS, C ;
JEROME, R ;
TEYSSIE, P .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1994, 168 (01) :222-229
[7]   OPTODE FOR BULK-RESPONSE MEMBRANES [J].
HAUSER, PC ;
PERISSET, PMJ ;
TAN, SSS ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1990, 62 (18) :1919-1923
[8]   Is smaller better? Scaling of characteristics with size of fiber-optic chemical and biochemical sensors [J].
Kopelman, R ;
Dourado, S .
CHEMICAL, BIOCHEMICAL, AND ENVIRONMENTAL FIBER SENSORS VIII, 1996, 2836 :2-11
[9]   Fibre-optic glucose biosensor using enzyme membranes with 2-D crystalline structure [J].
Neubauer, A ;
Pum, D ;
Sleytr, UB ;
Klimant, I ;
Wolfbeis, OS .
BIOSENSORS & BIOELECTRONICS, 1996, 11 (03) :317-325
[10]   Determination of anticholinesterase pesticides in real samples using a disposable biosensor [J].
Palchetti, I ;
Cagnini, A ;
DelCarlo, M ;
Coppi, C ;
Mascini, M ;
Turner, APF .
ANALYTICA CHIMICA ACTA, 1997, 337 (03) :315-321