Monitoring regional lung ventilation by functional electrical impedance tomography during assisted ventilation

被引:42
作者
Frerichs, I [1 ]
Hahn, G
Schiffmann, H
Berger, C
Hellige, G
机构
[1] Univ Gottingen, Ctr Anesthesiol Emergency & Intens Care Med, Dept Anesthesiol Res, D-37075 Gottingen, Germany
[2] Univ Gottingen, Dept Pediat, D-37075 Gottingen, Germany
来源
ELECTRICAL BIOIMPEDANCE METHODS: APPLICATIONS TO MEDICINE AND BIOTECHNOLOGY | 1999年 / 873卷
关键词
D O I
10.1111/j.1749-6632.1999.tb09498.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new approach in discriminating the regional air volume changes in the lungs associated with either spontaneous or mechanical ventilation during assisted ventilation is presented. Impedance data are obtained by conventional electrical impedance tomography (EIT). The data are filtered in the range of either the spontaneous or the ventilator rate and processed by the functional EIT (f-EIT) evaluation technique, whereby the variation of the respective EIT data with time is determined and imaged. EIT measurements performed in an infant during synchronized intermittent mandatory ventilation were evaluated with this method and indicated that the specific local lung volume swings related to spontaneous and mechanical inhalations can be separated and imaged as tomograms, This noninvasive approach may become useful in optimizing the ventilatory pattern during advanced forms of artificial ventilation and may help the clinician in the therapy management of individual patients.
引用
收藏
页码:493 / 505
页数:13
相关论文
共 28 条
[11]   Electrical impedance tomography in monitoring experimental lung injury [J].
Frerichs, I ;
Hahn, G ;
Schroder, T ;
Hellige, G .
INTENSIVE CARE MEDICINE, 1998, 24 (08) :829-836
[12]   EFFECTS OF ANESTHESIA AND PARALYSIS ON DIAPHRAGMATIC MECHANICS IN MAN [J].
FROESE, AB ;
BRYAN, AC .
ANESTHESIOLOGY, 1974, 41 (03) :242-255
[13]   Local mechanics of the lung tissue determined by functional EIT [J].
Hahn, G ;
Frerichs, I ;
Kleyer, M ;
Hellige, G .
PHYSIOLOGICAL MEASUREMENT, 1996, 17 :A159-A166
[14]   CHANGES IN THE THORACIC IMPEDANCE DISTRIBUTION UNDER DIFFERENT VENTILATORY CONDITIONS [J].
HAHN, G ;
SIPINKOVA, I ;
BAISCH, F ;
HELLIGE, G .
PHYSIOLOGICAL MEASUREMENT, 1995, 16 :A161-A173
[15]   MULTIFREQUENCY AND PARAMETRIC EIT IMAGES OF NEONATAL LUNGS [J].
HAMPSHIRE, AR ;
SMALLWOOD, RH ;
BROWN, BH ;
PRIMHAK, RA .
PHYSIOLOGICAL MEASUREMENT, 1995, 16 :A175-A189
[16]  
HOLDER DS, 1993, CLINICAL AND PHYSIOLOGICAL APPLICATIONS OF ELECTRICAL IMPEDANCE TOMOGRAPHY, P6
[17]   Electrical impedance tomography [J].
Kotre, CJ .
BRITISH JOURNAL OF RADIOLOGY, 1997, 70 :S200-S205
[18]   Gastric emptying patterns of a liquid meal in newborn infants measured by epigastric impedance [J].
Lange, A ;
FunchJensen, P ;
Thommesen, P ;
Schiotz, PO .
NEUROGASTROENTEROLOGY AND MOTILITY, 1997, 9 (02) :55-62
[19]   A COMPARISON OF VENTILATORY AND CARDIAC-RELATED CHANGES IN EIT IMAGES OF NORMAL HUMAN LUNGS AND OF LUNGS WITH PULMONARY EMBOLI [J].
LEATHARD, AD ;
BROWN, BH ;
CAMPBELL, J ;
ZHANG, F ;
MORICE, AH ;
TAYLER, D .
PHYSIOLOGICAL MEASUREMENT, 1994, 15 :A137-A146
[20]   Reproducibility of electrical impedance tomographic spectroscopy (EITS) parametric images of neonatal lungs [J].
Marven, SS ;
Hampshire, AR ;
Smallwood, RH ;
Brown, BH ;
Primhak, RA .
PHYSIOLOGICAL MEASUREMENT, 1996, 17 :A205-A212