A new method of measuring acetabular cup anteversion on simulated radiographs

被引:37
作者
Bachhal, Vikas [1 ]
Jindal, Nipun [2 ]
Saini, Gaurav [1 ]
Sament, Radheshyam [1 ]
Kumar, Vishal [1 ]
Chouhan, Devendra [1 ]
Dhillon, Mandeep [1 ]
机构
[1] Postgrad Inst Med Educ & Res, Dept Orthopaed, Chandigarh 160012, India
[2] Govt Med Coll & Hosp, Dept Orthopaed, Surat 395007, Gujarat, India
关键词
TOTAL HIP-ARTHROPLASTY; PLAIN RADIOGRAPHS; ORIENTATION; REPLACEMENT; DISLOCATION; COMPONENT; POSITION; MOTION;
D O I
10.1007/s00264-012-1583-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Optimal positioning of acetabular components is crucial for maintaining stability of THA. Postoperative assessment of acetabular anteversion is a vital but difficult task. Various methods have been devised with good results for measuring anteversion on plain radiographs but these methods are either too complicated or require special objects like scientific calculators, special protectors, tables, etc. A new simplified method of measuring anteversion on plain radiographs was created based on basic geometry. Anteversion of acetabular components was estimated on computer generated images of the acetabular cup by our method and compared with two previously established methods of Liaw and Pradhan. Measurement was done at 400 different positions of acetabular cup and compared with actual values. Another analysis was done after adding the femoral head to the acetabular component, thus obscuring some of the acetabular rim. Mean and standard deviation of error for our method was 0.77A degrees A +/- 0.75A degrees as compared to 0.93A degrees A +/- 0.86A degrees and 0.72A degrees A +/- 0.68A degrees for the methods of Liaw and Pardhan, respectively, with no significant differences from actual values. Maximal errors for our method, Liaw's and Pradhan's method were 3A degrees, 4A degrees, and 2.91A degrees, respectively. On analysis, after the adding femoral head, there was a significant error of measurement with Liaw's method, while our method as well as Pardhan's remained accurate. All methods showed high inter- and intraobserver reliability. Our new simplified method of measuring acetabular anteversion on plain radiographs is acceptable in comparision to other established methods and requires only routinely used goniometer and calliper.
引用
收藏
页码:1813 / 1818
页数:6
相关论文
共 18 条
[1]
ANTEVERSION OF THE ACETABULAR CUP - MEASUREMENT OF ANGLE AFTER TOTAL HIP-REPLACEMENT [J].
ACKLAND, MK ;
BOURNE, WB ;
UHTHOFF, HK .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1986, 68 (03) :409-413
[2]
The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios [J].
D'Lima, DD ;
Urquhart, AG ;
Buehler, KO ;
Walker, RH ;
Colwell, CW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (03) :315-321
[3]
Effects of acetabular abduction on cup wear rates in total hip arthroplasty [J].
Del Schutte, H ;
Lipman, AJ ;
Bannar, SM ;
Livermore, JT ;
Ilstrup, D ;
Morrey, BF .
JOURNAL OF ARTHROPLASTY, 1998, 13 (06) :621-626
[4]
Fabeck L, 1999, Acta Orthop Belg, V65, P485
[5]
EVALUATION OF ACETABULAR ANTEVERSION FOLLOWING TOTAL HIP ARTHROPLASTY - NECESSITY OF PROPER CENTERING [J].
GOERGEN, TG ;
RESNICK, D .
BRITISH JOURNAL OF RADIOLOGY, 1975, 48 (568) :259-260
[6]
Factors predisposing to dislocation after primary total hip arthroplasty - A multivariate analysis [J].
Jolles, BM ;
Zangger, P ;
Leyvraz, PF .
JOURNAL OF ARTHROPLASTY, 2002, 17 (03) :282-288
[7]
Position of the acetabular cup - accuracy of radiographic calculation compared to CT-based measurement [J].
Kalteis, T ;
Handel, M ;
Herold, T ;
Perlick, L ;
Paetzel, C ;
Grifka, J .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 58 (02) :294-300
[8]
The effect of acetabular cup orientations on limiting hip rotation [J].
Kummer, FJ ;
Shah, S ;
Iyer, S ;
DiCesare, PE .
JOURNAL OF ARTHROPLASTY, 1999, 14 (04) :509-513
[9]
DISLOCATIONS AFTER TOTAL HIP-REPLACEMENT ARTHROPLASTIES [J].
LEWINNEK, GE ;
LEWIS, JL ;
TARR, R ;
COMPERE, CL ;
ZIMMERMAN, JR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1978, 60 (02) :217-220
[10]
A new tool for measuring cup orientation in total hip arthroplasties from plain radiographs [J].
Liaw, Chen-Kun ;
Hou, Sheng-Mou ;
Yang, Rong-Sen ;
Wu, Tai-Yin ;
Fuh, Chiou-Shann .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (451) :134-139