Myocardial blood flow in patients with low-flow, low-gradient aortic stenosis: differences between true and pseudo-severe aortic stenosis. Results from the multicentre TOPAS (Truly or Pseudo-Severe Aortic Stenosis) study

被引:24
作者
Burwash, I. G. [1 ]
Lortie, M. [1 ]
Pibarot, P. [2 ]
de Kemp, R. A. [1 ]
Graf, S. [3 ]
Mundigler, G. [3 ]
Khorsand, A. [3 ]
Blais, C. [2 ]
Baumgartner, H. [3 ]
Dumesnil, J. G. [2 ]
Hachicha, Z. [2 ]
DaSilva, J. [1 ]
Beanlands, R. S. B. [1 ]
机构
[1] Univ Ottawa, Inst Heart, Div Cardiol, Ottawa, ON K1Y 4W7, Canada
[2] Univ Laval, Quebec Heart Inst, Ste Foy, PQ G1K 7P4, Canada
[3] Med Univ Vienna, Vienna, Austria
基金
加拿大健康研究院;
关键词
D O I
10.1136/hrt.2007.135475
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Background: Impairment of myocardial flow reserve (MFR) in aortic stenosis (AS) with normal left ventricular function relates to the haemodynamic severity. Objectives: To investigate whether myocardial blood flow (MBF) and MFR differ in low-flow, low-gradient AS depending on whether there is underlying true-severe AS (TSAS) or pseudo-severe AS (PSAS). Methods: In 36 patients with low-flow, low-gradient AS, dynamic [(13)N] ammonia PET perfusion imaging was performed at rest (n = 36) and during dipyridamole stress (n = 20) to quantify MBF and MFR. Dobutamine echocardiography was used to classify patients as TSAS (n = 18) or PSAS (n = 18) based on the indexed projected effective orifice area (EOA) at a normal flow rate of 250 ml/s (EOAI(proj) <= or >0.55 cm(2)/m(2)). Results: Compared with healthy controls (n = 14), patients with low-flow, low-gradient AS had higher resting mean (SD) MBF (0.83 (0.21) vs 0.69 (0.09) ml/min/g, p = 0.001), reduced hyperaemic MBF (1.16 (0.31) vs 2.71 (0.50) ml/min/g, p < 0.001) and impaired MFR (1.44 (0.44) vs 4.00 (0.91), p < 0.001). Resting MBF and MFR correlated with indices of AS severity in low-flow, low-gradient AS with the strongest relationship observed for EOAIproj (r(s) = 20.50, p = 0.002 and r(s) = 0.61, p = 0.004, respectively). Compared with PSAS, TSAS had a trend to a higher resting MBF (0.90 (0.19) vs 0.77 (0.21) ml/min/g, p = 0.06), similar hyperaemic MBF (1.16 (0.31) vs 1.17 (0.32) ml/min/g, p = NS), but a significantly smaller MFR (1.19 (0.26) vs 1.76 (0.41), p = 0.003). An MFR <1.8 had an accuracy of 85% for distinguishing TSAS from PSAS. Conclusions: Low-flow, low-gradient AS is characterised by higher resting MBF and reduced MFR that relates to the AS severity. The degree of MFR impairment differs between TSAS and PSAS and may be of value for distinguishing these entities.
引用
收藏
页码:1627 / 1633
页数:7
相关论文
共 39 条
[1]
Ananthasubramaniam K, 2005, CAN J CARDIOL, V21, P51
[2]
Positron emission tomography and recovery following revascularization (PARR-1): The importance of scar and the development of a prediction rule for the degree of recovery of left ventricular function [J].
Beanlands, RSB ;
Ruddy, TD ;
deKemp, RA ;
Iwanochko, RM ;
Coates, G ;
Freeman, M ;
Nahmias, C ;
Hendry, P ;
Burns, RJ ;
Lamy, A ;
Mickleborough, L ;
Kostuk, W ;
Fallen, E ;
Nichol, G .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (10) :1735-1743
[3]
Projected valve area at normal flow rate improves the assessment of stenosis severity in patients with low-flow, low-gradient aortic stenosis - The Multicenter TOPAS (truly or pseudo-severe aortic stenosis) study [J].
Blais, C ;
Burwash, IG ;
Mundigler, G ;
Dumesnil, JG ;
Loho, N ;
Rader, F ;
Baumgartner, H ;
Beanlands, RS ;
Chayer, B ;
Kadem, L ;
Garcia, D ;
Durand, LG ;
Pibarot, P .
CIRCULATION, 2006, 113 (05) :711-721
[4]
Results of aortic valve replacement for aortic stenosis with relatively low transvalvular pressure gradients [J].
Blitz, LR ;
Gorman, M ;
Herrmann, HC .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (03) :358-362
[5]
ACC/AHA 2006 guidelines for the management of patients with valvular heart disease [J].
Bonow, Robert O. ;
Carabello, Blase A. ;
Chatterjee, Kanu ;
de Leon, Antonio C., Jr. ;
Faxon, David P. ;
Freed, Michael D. ;
Gaasch, William H. ;
Lytle, Bruce Whitney ;
Nishimura, Rick A. ;
O'Gara, Patrick T. ;
O'Rourke, Robert A. ;
Otto, Catherine M. ;
Shah, Pravin M. ;
Shanewise, Jack S. ;
Smith, Sidney C., Jr. ;
Jacobs, Alice K. ;
Adams, Cynthia D. ;
Anderson, Jeffrey L. ;
Antman, Elliott M. ;
Faxon, David P. ;
Fuster, Valentin ;
Halperin, Jonathan L. ;
Hiratzka, Loren F. ;
Hunt, Sharon A. ;
Lytle, Bruce W. ;
Nishimura, Rick ;
Page, Richard L. ;
Riegel, Barbara .
CIRCULATION, 2006, 114 (05) :E84-E231
[6]
PROGNOSIS AFTER VALVE-REPLACEMENT IN PATIENTS WITH SEVERE AORTIC-STENOSIS AND A LOW TRANSVALVULAR PRESSURE-GRADIENT [J].
BROGAN, WC ;
GRAYBURN, PA ;
LANGE, RA ;
HILLS, LD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (07) :1657-1660
[8]
Hemodynamic stability of valve area, valve resistance, and stroke work loss in aortic stenosis: A comparative analysis [J].
Burwash, IG ;
Hay, KM ;
Chan, KL .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (08) :814-822
[9]
FLOW DEPENDENCE OF MEASURES OF AORTIC-STENOSIS SEVERITY DURING EXERCISE [J].
BURWASH, IG ;
PEARLMAN, AS ;
KRAFT, CD ;
MIYAKEHULL, C ;
HEALY, NL ;
OTTO, CM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (05) :1342-1350
[10]
DEPENDENCE OF GORLIN FORMULA AND CONTINUITY EQUATION VALVE AREAS ON TRANSVALVULAR VOLUME FLOW-RATE IN VALVULAR AORTIC-STENOSIS [J].
BURWASH, IG ;
THOMAS, DD ;
SADAHIRO, M ;
PEARLMAN, AS ;
VERRIER, ED ;
THOMAS, R ;
KRAFT, CD ;
OTTO, CM .
CIRCULATION, 1994, 89 (02) :827-835