Pitfalls in renal mass evaluation and how to avoid them

被引:116
作者
Israel, Gary M. [1 ]
Bosniak, Morton A. [2 ]
机构
[1] Yale Univ, Sch Med, Dept Diagnost Radiol, New Haven, CT 06520 USA
[2] NYU, Sch Med, Dept Radiol, New York, NY USA
关键词
D O I
10.1148/rg.285075744
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Characterization of renal masses with computed tomography (CT) and magnetic resonance (MR) imaging is usually clear-cut and accurate. However, potential pitfalls exist in diagnosis of renal masses, and it is necessary to understand these pitfalls to avoid misdiagnosis and possibly unnecessary surgery. Although some of the pitfalls are related to technical factors of the CT and MR imaging equipment, others are related to errors in image interpretation. To maximize detection and characterization of renal masses, the study should include images obtained before and after administration of intravenous contrast material, including images obtained during the nephrographic phase of enhancement. One should be aware of the potential unreliability of absolute Hounsfield unit measurements and of the existence of possible CT pseudoenhancement. When CT results are indeterminate, MR imaging may be helpful in demonstrating enhancement in renal masses. Before diagnosing a renal mass as a malignant neoplasm or suggesting surgery for a renal mass, one should consider alternative benign diagnoses; when appropriate, previous images or a supporting history should be obtained. (C) RSNA, 2008 . radiographics.rsnajnls.org.
引用
收藏
页码:1325 / 1338
页数:14
相关论文
共 45 条
[1]   Pseudoenhancement of simulated renal cysts in a phantom using different multidetector CT scanners [J].
Abdulla, C ;
Kalra, MK ;
Saini, S ;
Maher, MM ;
Ahmad, A ;
Halpern, E ;
Silverman, SG .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (06) :1473-1476
[2]   Renal cysts: Is attenuation artifactually increased on contrast-enhanced CT images? [J].
Bae, KT ;
Heiken, JP ;
Siegel, CL ;
Bennett, HF .
RADIOLOGY, 2000, 216 (03) :792-796
[3]   Complex renal cysts: Findings on MR imaging [J].
Balci, NC ;
Semelka, RC ;
Patt, RH ;
Dubois, D ;
Freeman, JA ;
Gomez-Caminero, A ;
Woosley, JT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (06) :1495-1500
[4]   Multiphasic renal CT: Comparison of renal mass enhancement during the corticomedullary and nephrographic phases [J].
Birnbaum, BA ;
Jacobs, JE ;
Ramchandani, P .
RADIOLOGY, 1996, 200 (03) :753-758
[5]   Renal cyst pseudoenhancement: Evaluation with an anthropomorphic body CT phantom [J].
Birnbaum, BA ;
Maki, DD ;
Chakraborty, DP ;
Jacobs, JE ;
Babb, JS .
RADIOLOGY, 2002, 225 (01) :83-90
[6]   Renal cyst pseudoenhancement: Influence of multidetector CT reconstruction algorithm and scanner type in phantom model [J].
Birnbaum, Bernard A. ;
Hindman, Nicole ;
Lee, Julie ;
Babb, James S. .
RADIOLOGY, 2007, 244 (03) :767-775
[7]   Multi-detector row CT attenuation measurements: Assessment of intra- and interscanner variability with an anthropomorphic body CT phantom [J].
Birnbaum, Bernard A. ;
Hindman, Nicole ;
Lee, Julie ;
Babb, James S. .
RADIOLOGY, 2007, 242 (01) :109-119
[9]   Problems in the detection and characterization of small renal masses [J].
Bosniak, MA ;
Rofsky, NM .
RADIOLOGY, 1996, 198 (03) :638-641
[10]   Should we biopsy complex cystic renal masses (Bosniak Category III)? [J].
Bosniak, MA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (05) :1425-1426