MR imaging: acronyms and clinical applications

被引:23
作者
Nitz, WR [1 ]
机构
[1] Klinikum Univ Regensburg, Inst Rontgendiadnost, D-93042 Regensburg, Germany
关键词
MR angiography; cine MR imaging; nuclear magnetic resonance;
D O I
10.1007/s003300050780
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The intention of this article is to provide an overview of all MR imaging techniques that are accessible on most of commercially available scanners and have the potential to be used in routine clinical applications. The techniques implemented by the major vendors are briefly explained, including a comparison of the commonly used acronyms. A classification scheme is introduced which provides a reasonable illustration of similarities and differences between various techniques. The imaging techniques are divided into two main groups, the spin-echo and gradient-echo sequences. Within each group is the basic sequence, those which require a preparation of the magnetization, those which use multiple echoes to fill the k-space and those which are performed in a single shot. For each technique the typical clinical applications are listed or the potential applications which have been published.
引用
收藏
页码:979 / 997
页数:19
相关论文
共 177 条
[1]  
ABBAS Y A, 1991, Magnetic Resonance Quarterly, V7, P275
[2]   Effects of gradient anisotropy in MRI [J].
Aldefeld, B ;
Börnert, P .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (04) :606-614
[3]   Study of susceptibility-induced artefacts in GRASE with different echo train length [J].
Allkemper, T ;
Reimer, P ;
Schuierer, G ;
Peters, PE .
EUROPEAN RADIOLOGY, 1998, 8 (05) :834-838
[4]   MULTI-PLANAR IMAGE-FORMATION USING NMR SPIN ECHOES [J].
MANSFIELD, P .
JOURNAL OF PHYSICS C-SOLID STATE PHYSICS, 1977, 10 (03) :L55-L58
[5]   1ST-PASS CARDIAC PERFUSION - EVALUATION WITH ULTRAFAST MR IMAGING [J].
ATKINSON, DJ ;
BURSTEIN, D ;
EDELMAN, RR .
RADIOLOGY, 1990, 174 (03) :757-762
[6]   STAGING URINARY-BLADDER CANCER - VALUE OF T1-WEIGHTED 3-DIMENSIONAL MAGNETIZATION PREPARED-RAPID GRADIENT-ECHO AND 2-DIMENSIONAL SPIN-ECHO SEQUENCES [J].
BARENTSZ, JO ;
JAGER, G ;
MUGLER, JP ;
OOSTERHOF, G ;
PETERS, H ;
VANERNING, LTJO ;
RUIJS, SHJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (01) :109-115
[7]   SPIN-LATTICE RELAXATION-TIME MEASUREMENT BY MEANS OF A TURBOFLASH TECHNIQUE [J].
BLUML, S ;
SCHAD, LR ;
STEPANOW, B ;
LORENZ, WJ .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (03) :289-295
[8]   DEGENERATIVE CARTILAGE LESIONS OF THE HIP - MAGNETIC-RESONANCE EVALUATION [J].
BONGARTZ, G ;
BOCK, E ;
HORBACH, T ;
REQUARDT, H .
MAGNETIC RESONANCE IMAGING, 1989, 7 (02) :179-186
[9]   MP RAGE - A 3-DIMENSIONAL, T1-WEIGHTED, GRADIENT-ECHO SEQUENCE - INITIAL EXPERIENCE IN THE BRAIN [J].
BRANTZAWADZKI, M ;
GILLAN, GD ;
NITZ, WR .
RADIOLOGY, 1992, 182 (03) :769-775
[10]   A NEW STEADY-STATE IMAGING SEQUENCE FOR SIMULTANEOUS ACQUISITION OF 2-MR IMAGES WITH CLEARLY DIFFERENT CONTRASTS [J].
BRUDER, H ;
FISCHER, H ;
GRAUMANN, R ;
DEIMLING, M .
MAGNETIC RESONANCE IN MEDICINE, 1988, 7 (01) :35-42