Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo

被引:225
作者
Busse, Reed F. [1 ]
Brau, Anja C. S. [2 ]
Vu, Anthony [3 ]
Michelich, Charles R. [3 ]
Bayram, Ersin [3 ]
Kijowski, Richard [4 ]
Reeder, Scott B. [4 ]
Rowley, Howard A. [4 ]
机构
[1] GE Healthcare, MR Appl Sci Lab, Madison, WI 53717 USA
[2] GE Healthcare, MR Appl Sci Lab, Menio Pk, CA USA
[3] GE Healthcare, MR Engn, Waukesha, WI USA
[4] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
关键词
RARE; fast spin echo; variable flip angle; view ordering; 3D-FSE;
D O I
10.1002/mrm.21680
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Recent advances have reduced scan time in three-dimensional fast spin echo (3D-FSE) imaging, including very long echo trains through refocusing flip angle (FA) modulation and 2D-accelerated parallel imaging. This work describes a method to modulate refocusing FAs that produces sharp point spread functions (PSFs) from very long echo trains while exercising direct control over minimum, center-k-space, and maximum FAs in order to accommodate the presence of flow and motion, SNR requirements, and RF power limits. Additionally, a new method for ordering views to map signal modulation from the echo train into k(y)-k(z) space that enables nonrectangular k-space grids and autocalibrating 2D-accelerated parallel imaging is presented. With long echo trains and fewer echoes required to encode large matrices, large volumes with high in- and through-plane resolution matrices may be acquired with scan times of 3-6 min, as demonstrated for volumetric brain, knee, and kidney imaging.
引用
收藏
页码:640 / 649
页数:10
相关论文
共 26 条
[1]
The sensitivity of low flip angle RARE imaging [J].
Alsop, DC .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (02) :176-184
[2]
Beatty P.J., 2007, PROC
[3]
Effect of windowing and zero-filled reconstruction of MRI data on spatial resolution and acquisition strategy [J].
Bernstein, MA ;
Fain, SB ;
Riederer, SJ .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (03) :270-280
[4]
Brau A, 2006, P 14 ANN M ISMRM SEA
[5]
Fast spin echo sequences with very long echo trains:: Design of variable refocusing flip angle schedules and generation of clinical T2 contrast [J].
Busse, RF ;
Hariharan, H ;
Vu, A ;
Brittain, JH .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (05) :1030-1037
[6]
Reduced RF power without blurring: Correcting for modulation of refocusing flip angle in FSE sequences [J].
Busse, RF .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (05) :1031-1037
[7]
Busse RF, 2007, P 15 ANN M ISMRM BER
[8]
BUSSE RF, 2006, P 14 ANN M ISMRM SEA
[9]
RARE IMAGING - A FAST IMAGING METHOD FOR CLINICAL MR [J].
HENNIG, J ;
NAUERTH, A ;
FRIEDBURG, H .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (06) :823-833
[10]
Calculation of flip angles for echo trains with predefined amplitudes with the extended phase graph (EPG)-algorithm: Principles and applications to hyperecho and TRAPS sequences [J].
Hennig, J ;
Weigel, M ;
Scheffler, K .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (01) :68-80