Rapid and sensitive immunodetection of Listeria monocytogenes in milk using a novel piezoelectric cantilever sensor

被引:69
作者
Sharma, Harsh [1 ]
Mutharasan, Raj [1 ]
机构
[1] Drexel Univ, Dept Chem & Biol Engn, Philadelphia, PA 19104 USA
关键词
Triple-binding-assay; Milk; Resonance frequency; ESCHERICHIA-COLI O157-H7; PATHOGEN DETECTION; PEMC SENSORS; BIOSENSOR; SAMPLES; FOOD; PCR; AMPLIFICATION; ASSAY; CELL;
D O I
10.1016/j.bios.2013.01.068
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Listeria mottocytogenes (LM), an important food-borne pathogen that has a high mortality rate (-30%), was successfully detected within an hour at the infection dose limit of 10(3)/mL, both in buffer and milk. LM detection was demonstrated using a novel asymmetrically anchored cantilever sensor and a commercially available antibody. Sensor responses were confirmed using a secondary antibody binding step, similar to the sandwich ELISA assays, as a means of signal amplification that also reduced the occurrence of false negatives. Detection of LM at a concentrations of 10(2)/mL was achieved, by incorporating a third antibody binding step, which is an order of magnitude smaller than the infection dose (< 1000 cells) for LM. The commercially available antibody for LM used in this work is shown to have low avidity which partially explains the relatively low sensitivity reported for LM as compared to other pathogens. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:158 / 162
页数:5
相关论文
共 30 条
[1]   Detection of Listeria monocytogenes using a commercial PCR kit and different DNA extraction methods [J].
Amagliani, G. ;
Giammarini, C. ;
Omiccioli, E. ;
Brandi, G. ;
Magnani, M. .
FOOD CONTROL, 2007, 18 (09) :1137-1142
[2]   Direct detection of Listeria monocytogenes from milk by magnetic based DNA isolation and PCR [J].
Amagliani, G ;
Brandi, G ;
Omiccioli, E ;
Casiere, A ;
Bruce, IJ ;
Magnani, M .
FOOD MICROBIOLOGY, 2004, 21 (05) :597-603
[3]   A survey of the 2006-2009 quartz crystal microbalance biosensor literature [J].
Becker, Bernd ;
Cooper, Matthew A. .
JOURNAL OF MOLECULAR RECOGNITION, 2011, 24 (05) :754-787
[4]   A method of measuring Escherichia coli O157:H7 at 1 cell/mL in 1 liter sample using antibody functionalized piezoelectric-excited millimeter-sized cantilever sensor [J].
Campbell, Gossett A. ;
Mutharasan, Raj .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2007, 41 (05) :1668-1674
[5]   Detect of Escherichia coli O157:H7 in ground beef samples using piezoelectric excited millimeter-sized cantilever (PEMC) sensors [J].
Campbell, Gossett A. ;
Uknalis, Joe ;
Tu, Shu-I ;
Mutharasan, Raj .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (07) :1296-1302
[6]   Detection of Bacillus anthracis spores and a model protein using PEMC sensors in a flow cell at 1 mL/min [J].
Campbell, Gossett A. ;
Mutharasan, Raj .
BIOSENSORS & BIOELECTRONICS, 2006, 22 (01) :78-85
[7]  
CDC, 2012, Multistate outbreak of listeriosis linked to whole cantaloupes from Jensen Farms, Colorado final update
[8]  
Donnelly CW, 2002, J AOAC INT, V85, P495
[9]  
Doyle MP, 2007, FOOD MICROBIOLOGY: FUNDAMENTALS AND FRONTIERS, THIRD EDITION, P1
[10]   Simultaneous detection of Escherichia coli O175:H7, Salmonella spp., and Listeria monocytogenes by multiplex PCR [J].
Germini, Andrea ;
Masola, Annalisa ;
Carnevali, Paola ;
Marchelli, Rosangela .
FOOD CONTROL, 2009, 20 (08) :733-738