Concentrations and emissions of gasoline and other vapors from residential vehicle garages

被引:59
作者
Batterman, S [1 ]
Hatzvasilis, G [1 ]
Jia, CR [1 ]
机构
[1] Univ Michigan, Ann Arbor, MI 48109 USA
关键词
air exchange; indoor air; garages; gasoline; volatile organic compounds;
D O I
10.1016/j.atmosenv.2005.11.017
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
High concentrations of airborne volatile organic compounds (VOCs) may be present in residential garages due to emissions from vehicles, lawnmowers, storage containers, and many other items stored in the garage. VOC emissions will ultimately be transported into ambient air and, if the garage is attached to a residence or other building, into living spaces. This study reports on VOC concentrations and emissions at 15 residential garages in Michigan that varied in type, size, use and other characteristics. VOCs were measured in garages and in outside air using 4-day passive sampling, thermal desorption, and GC-MS analysis. Effective air exchange rates (AERs) were determined using a perfluorocarbon tracer gas and the constant injection method. A modeling analysis shows the effect of time-varying ventilation. To estimate temporal and spatial variability, concentrations were measured on 7 subsequent occasions at multiple locations in one garage. This garage was well-mixed, and the temporal variation in AERs and concentrations was modest. Across the 15 garages, 36 different VOCs in garage air, and 20 in ambient air, were quantified. Source groups identified and attributed to garage emissions included evaporated gasoline, solvents, paints, oils, and cleaners. Concentrations of gasoline-related VOCs in most garages were high, e.g., benzene levels reached 159 mu g m(-3) in one garage. TVOC emissions per garage averaged 3.0 +/- 4.1 g day(-1), and AERs averaged 0.77 +/- 0.51 h(-1). VOC concentrations and AERs were not strongly correlated to observed house, garage or meteorological factors, but appeared largely dependent on occupant activities (opening of the garage door) and VOC sources present. This study quantifies the importance of attached garages as VOC sources, and the results are significant for understanding and mitigating indoor exposures, and for estimating emissions for source inventory purposes. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1828 / 1844
页数:17
相关论文
共 46 条
[1]  
American Society of Heating Refrigerating and Air Conditioning Engineers Inc. (ASHRAE), 2003, 62 ASHRAE
[2]  
[Anonymous], EPA625R96010B CTR EN
[3]  
[Anonymous], 2004, LBNL53356
[4]  
*ATSDR, 2004, TOXFAQS CHLOR
[5]   Low-flow active and passive sampling of VOCs using thermal desorption tubes: theory and application at an offset printing facility [J].
Batterman, S ;
Metts, T ;
Kalliokoski, P ;
Barnett, E .
JOURNAL OF ENVIRONMENTAL MONITORING, 2002, 4 (03) :361-370
[6]   Non-methane hydrocarbon emissions from vehicle fuel caps [J].
Batterman, SA ;
Yu, YD ;
Jia, CR ;
Godwin, C .
ATMOSPHERIC ENVIRONMENT, 2005, 39 (10) :1855-1867
[7]   Levels and composition of volatile organic compounds on commuting routes in Detroit, Michigan [J].
Batterman, SA ;
Peng, CY ;
Braun, J .
ATMOSPHERIC ENVIRONMENT, 2002, 36 (39-40) :6015-6030
[8]   Volatile organic pollutants in new and established buildings in Melbourne, Australia [J].
Brown, SK .
INDOOR AIR, 2002, 12 (01) :55-63
[9]   NEW APPROACH FOR MEASURING AIR-FLOWS IN BUILDINGS USING A PERFLUOROCARBON TRACER [J].
CHEONG, KW ;
RIFFAT, SB .
APPLIED ENERGY, 1995, 51 (03) :223-232
[10]   INDOOR OUTDOOR MEASUREMENTS OF VOLATILE ORGANIC-COMPOUNDS IN THE KANAWHA VALLEY OF WEST-VIRGINIA [J].
COHEN, MA ;
RYAN, PB ;
YANAGISAWA, Y ;
SPENGLER, JD ;
OZKAYNAK, H ;
EPSTEIN, PS .
JAPCA-THE JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1989, 39 (08) :1086-1093