Can a clinically useful aortic pressure wave be derived from a radial pressure wave?

被引:68
作者
Söderström, S [1 ]
Nyberg, G
O'Rourke, MF
Sellgren, J
Pontén, J
机构
[1] Sahlgrens Univ Hosp, Dept Anaesthesia & Intens Care, S-41345 Gothenburg, Sweden
[2] Sahlgrens Univ Hosp, Dept Clin Physiol, S-41345 Gothenburg, Sweden
[3] Univ New S Wales, St Vincents Hosp, Dept Cardiol, Darlinghurst, NSW 2010, Australia
关键词
arterial pressure; hypnotics; benzodiazepine; midazolam; anaesthetic techniques; hypotensive; pharmacology; nitroglycerin;
D O I
10.1093/bja/88.4.481
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. The information contained in arterial pressure waveforms is probably under-used by most clinicians who manage critically ill patients. It is not generally known that an aortic pressure wave can be synthesized by applying a generalized transfer function to the radial arterial pressure wave. We validated a commercially available system, SphygmoCor(TM) (PWV Medical, Sydney). Methods. Ascending aortic pressure waves were synthesized and comparisons were made between the synthesized aortic waveforms, the measured aortic and radial arterial waveforms. Ascending aortic pressure waves (catheter-tip manometer) and radial artery pressure waves (short fluid-filled catheter) were recorded simultaneously in 12 patients with angina pectoris (age 62-76 years) undergoing cardiac catheterization. Patients were studied at rest, following midazolam, sublingual nitroglycerin and during Valsalva manoeuvres. Results. Both midazolam and nitroglycerin lowered mean arterial pressure but nitroglycerin caused a more selective decrease in the measured and synthesized aortic systolic pressures than in the radial artery pressure. The synthesized aortic systolic pressure was less, by 6-8 mm Hg (SD 2-3) and the synthesized aortic diastolic pressure greater, by 4 mm Hg (SD 2). Despite these differences in pulse pressure, the synthesized waveform tracked the measured waveform before and during interventions. Conclusions. By deriving an aortic waveform from the radial pulse, monitoring of left ventricular afterload can improve without more invasive means.
引用
收藏
页码:481 / 488
页数:8
相关论文
共 24 条
[1]   IN-VIVO COMPARISON BETWEEN 2-TIP PRESSURE TRANSDUCER SYSTEMS [J].
AUBERT, AE ;
VROLIX, M ;
DEGEEST, H ;
VANDEWERF, F .
INTERNATIONAL JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1995, 12 (02) :77-83
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
BUCKBERG GD, 1972, J THORAC CARDIOV SUR, V64, P669
[4]  
Chen CH, 1997, CIRCULATION, V95, P1827
[5]   Photoplethysmographic assessment of pulse wave reflection -: Blunted response to endothelium-dependent beta2-adrenergic vasodilation in type II diabetes mellitus [J].
Chowienczyk, PJ ;
Kelly, RP ;
MacCallum, H ;
Millasseau, SC ;
Andersson, TLG ;
Gosling, RG ;
Ritter, JM ;
Änggård, EE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (07) :2007-2014
[6]   Parametric model derivation of transfer function for noninvasive estimation of aortic pressure by radial tonometry [J].
Fetics, B ;
Nevo, E ;
Chen, CH ;
Kass, DA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1999, 46 (06) :698-706
[7]   DIRECT BLOOD-PRESSURE MEASUREMENT - DYNAMIC-RESPONSE REQUIREMENTS [J].
GARDNER, RM .
ANESTHESIOLOGY, 1981, 54 (03) :227-236
[8]   The patterns of the arterial pressure pulse [J].
Hamilton, WF .
AMERICAN JOURNAL OF PHYSIOLOGY, 1944, 141 (02) :0235-0241
[9]   AN ANALYSIS OF THE RELATIONSHIP BETWEEN CENTRAL AORTIC AND PERIPHERAL UPPER LIMB PRESSURE WAVES IN MAN [J].
KARAMANOGLU, M ;
OROURKE, MF ;
AVOLIO, AP ;
KELLY, RP .
EUROPEAN HEART JOURNAL, 1993, 14 (02) :160-167
[10]   PRESSURE WAVE-PROPAGATION IN A MULTIBRANCHED MODEL OF THE HUMAN UPPER-LIMB [J].
KARAMANOGLU, M ;
GALLAGHER, DE ;
AVOLIO, AP ;
OROURKE, MF .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1995, 269 (04) :H1363-H1369