Recombinant luminescent bacterial sensors for the measurement of bioavailability of cadmium and lead in soils polluted by metal smelters

被引:77
作者
Ivask, A
François, M
Kahru, A
Dubourguier, HC
Virta, M
Douay, F
机构
[1] NICPB, Mol Genet Lab, EE-12618 Tallinn, Estonia
[2] Lab Sols & Environm, F-59046 Lille, France
[3] Univ Turku, Dept Biotechnol, FIN-20520 Turku, Finland
基金
芬兰科学院;
关键词
bacteria; bioavailability; polluted soils; bioluminescence; zinc; mobility;
D O I
10.1016/j.chemosphere.2003.10.064
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Environmental hazard of heavy metals in soils depends to a large extent on their bioavailability. The approach used in this study enables the determination of bioavailable metals in solid-phase samples. Two recombinant bacterial sensors, one responding specifically to cadmium and the other to lead and cadmium by increase of luminescence (firefly luciferase was used as a reporter) were used to determine the bioavailability of these metals in soil-water suspensions (a contact assay) and respective particle-free extracts. Fifty agricultural soils sampled near zinc and lead smelters in the Northern France containing up to (mg/kg) 20.1 of Cd, 1050 of Pb and 1390 of Zn were analysed. As the soil matrix interferes with the assay, recombinant luminescent control bacteria lacking the metal recognizing protein and corresponding promoter (thus, being not metal-inducible) but otherwise comparable to the sensor bacteria (the same host bacterium and plasmid encoding luciferase) were used in parallel to take into account the possible quenching and/or stimulating effects of the sample on the luminescence of the sensor bacteria. Both, chemical and sensor analysis showed that only mug/l levels of metals were extracted from the soil into the water phase (0.1% of the total Cd, 0.07% of Pb and 0.5% of Zn). However, 115-fold more Cd and 40-fold more Pb proved bioavailable if the sensor bacteria were incubated in soil suspensions (i.e., in the contact assay). The bioavailability of metals in different soils varied (depending probably on soil type) ranging from 0.5% to 56% for cadmium and from 0.2% to 8.6% for lead. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:147 / 156
页数:10
相关论文
共 30 条
  • [11] Lappalainen J, 1999, CHEMOSPHERE, V38, P1069
  • [12] Lappalainen JO, 2000, ENVIRON TOXICOL, V15, P443, DOI 10.1002/1522-7278(2000)15:5<443::AID-TOX12>3.0.CO
  • [13] 2-L
  • [14] EXPRESSION OF BIOLOGICALLY-ACTIVE HUMAN T-CELL LYMPHOTROPIC VIRUS TYPE-III REVERSE-TRANSCRIPTASE IN BACILLUS-SUBTILIS
    LEGRICE, SFJ
    BEUCK, V
    MOUS, J
    [J]. GENE, 1987, 55 (01) : 95 - 103
  • [15] Long GL, 1983, ANAL CHEM, V55, p712A, DOI [DOI 10.1021/AC00258A001, 10.1021/ac00258a001]
  • [16] Prediction of metal bioavailability in Dutch field soils for the oligochaete Enchytraeus crypticus
    Peijnenburg, WJGM
    Posthuma, L
    Zweers, PGPC
    Baerselman, R
    de Groot, AC
    Van Veen, RPM
    Jager, T
    [J]. ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 1999, 43 (02) : 170 - 186
  • [17] Toxicity and bioavailability to bacteria of particle-associated arsenite and mercury
    Petänen, T
    Romantschuk, M
    [J]. CHEMOSPHERE, 2003, 50 (03) : 409 - 413
  • [18] Use of bioluminescent bacterial sensors as an alternative method for measuring heavy metals in soil extracts
    Petänen, U
    Romantschuk, M
    [J]. ANALYTICA CHIMICA ACTA, 2002, 456 (01) : 55 - 61
  • [19] Certification of trace metal extractable contents in a sediment reference material (CRM 601) following a three-step sequential extraction procedure
    Quevauviller, P
    Rauret, G
    LopezSanchez, JF
    Rubio, R
    Ure, A
    Muntau, H
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 1997, 205 (2-3) : 223 - 234
  • [20] Application of a mer-lux biosensor for estimating bioavailable mercury in soil
    Rasmussen, LD
    Sorensen, SJ
    Turner, RR
    Barkay, T
    [J]. SOIL BIOLOGY & BIOCHEMISTRY, 2000, 32 (05) : 639 - 646