A CCD-based optical CT scanner for high-resolution 3D imaging of radiation dose distributions: equipment specifications, optical simulations and preliminary results

被引:111
作者
Doran, SJ [1 ]
Koerkamp, KK
Bero, MA
Jenneson, P
Morton, EJ
Gilboy, WB
机构
[1] Univ Surrey, Dept Phys, Surrey GU2 7XH, England
[2] Univ Twente, Dept Appl Phys, NL-7500 AE Enschede, Netherlands
关键词
D O I
10.1088/0031-9155/46/12/309
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Methods based on magnetic resonance imaging for the measurement of three-dimensional distributions of radiation dose are highly developed. However. relatively little work has been done on optical computed tomography (OCT). This paper describes a new OCT scanner based on a broad beam light source and a two-dimensional charge-coupled device (CCD) detector. A number of key design features are discussed including the light source; the scanning tank, turntable and stepper motor control; the diffuser screen onto which images are projected and the detector. It is shown that the non-uniform pixel sensitivity of the low-cost CCD detector used and the granularity of the diffuser screen lead to a serious ring artefact in the reconstructed images. Methods are described for eliminating this. The problems arising from reflection and refraction at the walls of the gel container are explained. Optical ray-tracing simulations are presented for cylindrical containers with a variety of radii and verified experimentally. Small changes in the model parameters lead to large variations in the signal intensity observed in the projection data. The effect of imperfect containers on data quality is discussed and a method based on a 'correction scan' is shown to be successful in correcting many of the related image artefacts. The results of two tomography experiments are presented. In the first experiment, a radiochromic Fricke gel sample was exposed four times in different positions to a 100 kVp x-ray beam perpendicular to the plane of imaging. Images of absorbed dose with slice thickness of 140 mum were acquired, with 'true' in-plane resolution of 560 x 560 mum(2) at the edge of the 72 mm field of view and correspondingly higher resolution at the centre. The nominal doses measured correlated well with the known exposure times. The second experiment demonstrated the well known phenomenon of diffusion in the dosemeter gels and yielded a value of (0.12 +/- 0.02) mm(2) s(-1) for the diffusion coefficient of the xylenol orange/iron complex. Finally, the overall implications of the above findings for dosimetry using OCT are discussed.
引用
收藏
页码:3191 / 3213
页数:23
相关论文
共 22 条
[1]   IMAGING OF RADIATION-DOSE BY VISIBLE COLOR DEVELOPMENT IN FERROUS-AGAROSE-XYLENOL ORANGE GELS [J].
APPLEBY, A ;
LEGHROUZ, A .
MEDICAL PHYSICS, 1991, 18 (02) :309-312
[2]  
BACK AJ, 1999, P DOSGEL 99 1 INT WO
[3]   Three-dimensional radiation dose measurements with ferrous benzoic acid xylenol orange in gelatin gel and optical absorption tomography [J].
Bero, MA ;
Gilboy, WB ;
Glover, PM ;
Keddie, JL .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3) :617-620
[4]   Tissue-equivalent gel for non-invasive spatial radiation dose measurements [J].
Bero, MA ;
Gilboy, WB ;
Glover, PM ;
El-masri, HM .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2000, 166 :820-825
[5]  
BERO MA, 1999, P 1 INT WORKSH RAD T
[6]   Linear accelerator radiosurgery in the management of brain tumours [J].
Friedman, WA ;
Foote, KD .
ANNALS OF MEDICINE, 2000, 32 (01) :64-80
[7]   Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels .1. Development of an optical scanner [J].
Gore, JC ;
Ranade, M ;
Maryanski, MJ ;
Schulz, RJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (12) :2695-2704
[8]   Polymer gel dosimetry using x-ray computed tomography: a feasibility study [J].
Hilts, M ;
Audet, C ;
Duzenli, C ;
Jirasek, A .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (09) :2559-2571
[9]  
Jordan K., 1999, P DOSGEL 99 1 INT WO
[10]  
JORDAN K, 2000, P WORLD C MED PHYS B