Biomechanical investigation of the type and configuration of screws used in high tibial osteotomy with titanium locking plate and screw fixation

被引:21
作者
Chen, Yen-Nien [1 ,2 ]
Chang, Chih-Wei [1 ,3 ,4 ,5 ]
Li, Chun-Ting [6 ]
Chen, Chih-Hsien [1 ,7 ]
Chung, Chi-Rung [8 ]
Chang, Chih-Han [1 ]
Peng, Yao-Te [1 ,9 ]
机构
[1] Natl Cheng Kung Univ, Dept BioMed Engn, 1 Univ Rd, Tainan 701, Taiwan
[2] Show Chwan Mem Hosp, Dept Orthoped, Changhua, Taiwan
[3] Natl Cheng Kung Univ, Coll Med, Dept Orthoped, Tainan, Taiwan
[4] Natl Cheng Kung Univ, Natl Cheng Kung Univ Hosp, Collage Med, Dept Orthoped, Tainan, Taiwan
[5] Natl Cheng Kung Univ, Natl Cheng Kung Univ Hosp, Collage Med, Joint Reconstruct Ctr, Tainan, Taiwan
[6] Natl Univ Tainan, Grad Inst Mech Syst Engn, Tainan, Taiwan
[7] Show Chwan Med Care Corp, Tainan Municipal Hosp, Dept Orthopaed Surg, Tainan, Taiwan
[8] Chi Mei Med Ctr, Dept Orthoped, Tainan, Taiwan
[9] Met Ind Res & Dev Ctr, Kaohsiung, Taiwan
关键词
High tibial osteotomy; Open wedge; Screw stress; Far-cortical locking screw; Finite element method; LATERAL HINGE FRACTURE; FAR CORTICAL LOCKING; TRABECULAR BONE; STIFFNESS; CONSTRUCT; MENISCUS;
D O I
10.1186/s13018-019-1062-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Background: To maintain the corrected alignment after high tibial osteotomy (HTO), fixation with titanium locking plate and screws is widely used in current practice; however, screw breakage is a common complication. Thus, this study was to investigate the mechanical stability of HTO with locking plate and various screw fixations, including the length as well as the type. Methods: A finite element (FE) model involving a distal femur, meniscus, and a proximal tibia with HTO fixed with a titanium locking plate and screws was created. The angle of the medial open wedge was 12 degrees, and bone graft was not used. Two types of screws, namely conventional locking and far-cortical locking screws, with various lengths and configurations were used. At the proximal tibia, conventional locking screws with different lengths, 30 and 55 mm, were used; at the tibia shaft, different screw fixations including one-cortical, two-cortical, and far-cortical locking screws were used. Results: The use of far-cortical locking screw generated the highest equivalent stress on the screws, which was four times (from 1373 to 541 MPa) higher than that of the one-cortical screw. Also, it led to the maximum deformation of the tibia and a greater gap deformation at the osteotomy site, which was twice (from 0.222 to 0.442 mm) larger than that of the one-cortical screw. The effect of different locking screw length on tibia deformation and implant stress was minor. Conclusion: Thus, far-cortical locking screws and plates increase interfragmentary movement but the screw stress is relatively high. Increasing the protection time (partial weight duration) is suggested to decrease the risk of screw breakage in HTO through fixation with titanium far-cortical locking screws and plates.
引用
收藏
页数:8
相关论文
共 33 条
[1]
The long-term outcome of high tibial osteotomy - A ten- to 20-year follow-up [J].
Akizuki, S. ;
Shibakawa, A. ;
Takizawa, T. ;
Yamazaki, I. ;
Horiuchi, H. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (05) :592-596
[2]
Biomechanics of high tibial osteotomy [J].
Amis, Andrew A. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (01) :197-205
[3]
Far Cortical Locking Can Reduce Stiffness of Locked Plating Constructs While Retaining Construct Strength [J].
Bottlang, Michael ;
Doornink, Josef ;
Fitzpatrick, Daniel C. ;
Madey, Steven M. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (08) :1985-1994
[4]
COMPARISON OF MATERIAL PROPERTIES IN FASCICLE-BONE UNITS FROM HUMAN PATELLAR TENDON AND KNEE LIGAMENTS [J].
BUTLER, DL ;
KAY, MD ;
STOUFFER, DC .
JOURNAL OF BIOMECHANICS, 1986, 19 (06) :425-432
[5]
Role of screw proximity in the fixation of transverse patellar fractures with screws and a wire [J].
Chang, Chih-Wei ;
Chen, Yen-Nien ;
Li, Chun-Ting ;
Chung, Yu-Hsuan ;
Chang, Chih-Han ;
Peng, Yao-Te .
JOURNAL OF ORTHOPAEDIC SURGERY, 2018, 26 (03)
[6]
Numerical investigation of fracture impaction in proximal humeral fracture fixation with locking plate and intramedullary nail [J].
Chen, Yen-Nien ;
Chang, Chih-Wei ;
Lin, Chia-Wei ;
Wang, Chih-Wei ;
Peng, Yao-Te ;
Chang, Chih-Han ;
Li, Chun-Ting .
INTERNATIONAL ORTHOPAEDICS, 2017, 41 (07) :1471-1480
[7]
Biomechanical investigation of titanium elastic nail prebending for treating diaphyseal long bone fractures [J].
Chen, Yen-Nien ;
Lee, Pei-Yuan ;
Chang, Chih-Wei ;
Ho, Yi-Hung ;
Peng, Yao-Te ;
Chang, Chih-Han ;
Li, Chun-Ting .
AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2017, 40 (01) :115-126
[8]
Computational comparison of tibial diaphyseal fractures fixed with various degrees of prebending of titanium elastic nails and with and without end caps [J].
Chen, Yen-Nien ;
Lee, Pei-Yuan ;
Chang, Chih-Han ;
Chang, Chih-Wei ;
Ho, Yi-Hung ;
Li, Chun-Ting ;
Peng, Yao-Te .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 (10) :2339-2346
[9]
Dynamic Intraoperative ligament balancing for total knee arthroplasty [J].
D'Lima, Darryl D. ;
Patil, Shantanu ;
Steklov, Nikolai ;
Colwell, Clifford W., Jr. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (463) :208-212
[10]
Far Cortical Locking Enables Flexible Fixation With Periarticular Locking Plates [J].
Doornink, Josef ;
Fitzpatrick, Daniel C. ;
Madey, Steven M. ;
Bottlang, Michael .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 :S29-S34