Far Cortical Locking Enables Flexible Fixation With Periarticular Locking Plates

被引:64
作者
Doornink, Josef [1 ]
Fitzpatrick, Daniel C. [2 ]
Madey, Steven M. [1 ]
Bottlang, Michael [1 ]
机构
[1] Legacy Res & Technol Ctr, Biomech Lab, Portland, OR USA
[2] Slocum Ctr Orthoped & Sports Med, Eugene, OR USA
关键词
supercondylar fracture; osteosynthesis; locking plate; biomechanics; femur; DISTAL FEMUR FRACTURES; RETROGRADE INTRAMEDULLARY NAIL; LOCKED PLATING CONSTRUCTS; INTERNAL-FIXATION; TIBIAL FRACTURES; STABILITY; STIFFNESS; SCREW; FIXATORS; LISS;
D O I
10.1097/BOT.0b013e3182070cda
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
The high stiffness of periarticular locked plating constructs can suppress callus formation and fracture healing. Replacing standard locking screws with far cortical locking (FCL) screws can decrease construct stiffness and can improve fracture healing in diaphyseal plating constructs. However, FCL function has not been tested in conjunction with periarticular plating constructs in which FCL screws are confined to the diaphyseal segment. This biomechanical study evaluated if diaphyseal fixation of a periarticular locking plate with FCL screws reduces construct stiffness and induces parallel interfragmentary motion without decreasing construct strength. Periarticular locking plates were applied to stabilize distal femur fractures in 22 paired femurs using either a standard locked plating approach (LP group) or FCL for diaphyseal fixation (FCL group) using MotionLoc screws (Zimmer, Warsaw, IN). Each specimen was evaluated under quasiphysiological loading to assess construct stiffness, construct durability under dynamic loading, and residual strength after dynamic loading. FCL constructs had an 81% lower initial stiffness than LP constructs. They induced nearly five times more interfragmentary motion than LP constructs under one body weight loading (P < 0.001). FCL constructs generated parallel interfragmentary motion, whereas LP constructs exhibited 48% less motion at the near cortex than at the far cortex (P = 0.002). Seven LP constructs and eight FCL constructs survived 100,000 loading cycles. The residual strength of surviving constructs was 4.9 +/- 1.6 kN (LP group) and 5.3 +/- 1.1 kN (FCL group, P = 0.73). In summary, FCL screws reduce stiffness, generate parallel interfragmentary motion, and retain the strength of a periarticular locked plating construct. Therefore, FCL fixation may be advisable for stiffness reduction of periarticular plating constructs to promote fracture healing by callus formation.
引用
收藏
页码:S29 / S34
页数:6
相关论文
共 27 条
[1]
Hip contact forces and gait patterns from routine activities [J].
Bergmann, G ;
Deuretzbacher, G ;
Heller, M ;
Graichen, F ;
Rohlmann, A ;
Strauss, J ;
Duda, GN .
JOURNAL OF BIOMECHANICS, 2001, 34 (07) :859-871
[2]
Comparison of the LISS and a retrograde-inserted supracondylar intramedullary nail for fixation of a periprosthetic distal femur fracture proximal to a total knee arthroplasty [J].
Bong, MR ;
Egol, KA ;
Koval, KJ ;
Kummer, FJ ;
Su, ET ;
Iesaka, K ;
Bayer, J ;
Di Cesare, PE .
JOURNAL OF ARTHROPLASTY, 2002, 17 (07) :876-881
[3]
Far Cortical Locking Can Improve Healing of Fractures Stabilized with Locking Plates [J].
Bottlang, Michael ;
Lesser, Maren ;
Koerber, Julia ;
Doornink, Josef ;
von Rechenberg, Brigitte ;
Augat, Peter ;
Fitzpatrick, Daniel C. ;
Madey, Steven M. ;
Marsh, J. Lawrence .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (07) :1652-1660
[4]
Far Cortical Locking Can Reduce Stiffness of Locked Plating Constructs While Retaining Construct Strength [J].
Bottlang, Michael ;
Doornink, Josef ;
Fitzpatrick, Daniel C. ;
Madey, Steven M. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (08) :1985-1994
[5]
A Nonlocking End Screw Can Decrease Fracture Risk Caused by Locked Plating in the Osteoporotic Diaphysis [J].
Bottlang, Michael ;
Doornink, Josef ;
Byrd, Gregory D. ;
Fitzpatrick, Daniel C. ;
Madey, Steven M. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (03) :620-627
[6]
Comparison of the mechanical performance of three types of external fixators: Linear, circular and hybrid [J].
Caja, VL ;
Kim, W ;
Larsson, S ;
Chao, EYS .
CLINICAL BIOMECHANICS, 1995, 10 (08) :401-406
[7]
Claes LE, 1998, CLIN ORTHOP RELAT R, pS132
[8]
The dynamic locking screw (DLS) can increase interfragmentary motion on the near cortex of locked plating constructs by reducing the axial stiffness [J].
Doebele, Stefan ;
Horn, Carsten ;
Eichhorn, Stefan ;
Buchholtz, Arne ;
Lenich, Andreas ;
Burgkart, Rainer ;
Nuessler, Andreas K. ;
Lucke, Martin ;
Andermatt, Daniel ;
Koch, Rudolf ;
Stoeckle, Ulrich .
LANGENBECKS ARCHIVES OF SURGERY, 2010, 395 (04) :421-428
[9]
Biomechanics of locked plates and screws [J].
Egol, KA ;
Kubiak, EN ;
Fulkerson, E ;
Kummer, FJ ;
Koval, KJ .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (08) :488-493
[10]
STABILITY OF 10 CONFIGURATIONS OF THE HOFFMANN EXTERNAL-FIXATION FRAME [J].
FINLAY, JB ;
MOROZ, TK ;
RORABECK, CH ;
DAVEY, JR ;
BOURNE, RB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1987, 69A (05) :734-744