Performance of a miniature high-temperature superconducting (HTS) surface coil for in vivo microimaging of the mouse in a standard 1.5T clinical whole-body scanner

被引:26
作者
Poirier-Quinot, Marie [1 ]
Ginefri, Jean-Christophe [1 ]
Girard, Olivier [1 ]
Robert, Philippe [2 ]
Darrasse, Luc [1 ]
机构
[1] Univ Paris 11, UMF 8081, URM22, CNRS, F-91405 Orsay, France
[2] Guerbet Res, Aulnay Sous Bois, France
关键词
MR microscopy; high-temperature superconductor (HTS); miniature radiofrequency (RF) coil; clinical whole-body scanner; small animal; mouse;
D O I
10.1002/mrm.21605
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The performance of a 12-mm high-temperature superconducting (HTS) surface coil for in vivo microimaging of mice in a standard 1.5T clinical whole-body scanner was investigated. Systematic evaluation of MR image quality was conducted on saline phantoms with various conductivities to derive the sensitivity improvement brought by the HTS coil compared with a similar room-temperature copper coil. The observed signal-to-noise ratio (SNR) was correlated to the loaded quality factor of the radio frequency (RF) coils and is theoretically validated with respect to the noise contribution of the MR acquisition channel. The expected in vivo SNR gain was then extrapolated for different anatomical sites by monitoring the quality factor in situ during animal imaging experiments. Typical SNR gains of 9.8, 9.8, 5.4, and 11.6 were found for brain, knee, back, and subcutaneous implanted tumors, respectively, over a series of mice. Excellent in vivo image quality was demonstrated in 16 min with native voxels down to (59 mu m)(3) with an SNR of 20. The HTS coil technology opens the way, for the first time at the current field strength of clinical MR scanners, to spatial resolutions below 10(-3) mm(3) in living mice, which until now were only accessible to specialized high-field MR microscopes.
引用
收藏
页码:917 / 927
页数:11
相关论文
共 48 条
[21]   SMALL ANIMAL IMAGING WITH A CLINICAL MAGNETIC-RESONANCE IMAGER [J].
HENKELMAN, RM ;
VANHETEREN, JG ;
BRONSKILL, MJ .
MAGNETIC RESONANCE IN MEDICINE, 1987, 4 (01) :61-66
[22]   In vivo MRI of cancer cell fate at the single-cell level in a mouse model of breast cancer metastasis to the brain [J].
Heyn, Chris ;
Ronald, John A. ;
Ramadan, Soha S. ;
Snir, Jonatan A. ;
Barry, Andrea M. ;
MacKenzie, Lisa T. ;
Mikulis, David J. ;
Palmieri, Diane ;
Bronder, Julie L. ;
Steeg, Patricia S. ;
Yoneda, Toshiyuki ;
MacDonald, Ian C. ;
Chambers, Ann F. ;
Rutt, Brian K. ;
Foster, Paula J. .
MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (05) :1001-1010
[23]  
Hurlston SE, 1999, MAGNET RESON MED, V41, P1032, DOI 10.1002/(SICI)1522-2594(199905)41:5<1032::AID-MRM23>3.3.CO
[24]  
2-O
[25]   POTENTIAL BENEFITS OF A CRYOGENICALLY COOLED NMR PROBE FOR ROOM-TEMPERATURE SAMPLES [J].
JEROSCHHEROLD, M ;
KIRSCHMAN, RK .
JOURNAL OF MAGNETIC RESONANCE, 1989, 85 (01) :141-146
[26]   In vivo MRI using liquid nitrogen cooled phased array coil at 3.0 T [J].
Kwok, Wingchi E. ;
You, Zhigang .
MAGNETIC RESONANCE IMAGING, 2006, 24 (06) :819-823
[27]   Diffusion tensor imaging (DTI) of rodent brains in vivo using a 1.5T clinical MR scanner [J].
Lee, FKH ;
Fang, MR ;
Antonio, GE ;
Yeung, DKW ;
Chan, ETY ;
Zhang, LH ;
Yew, DT ;
Ahuja, AT .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (05) :747-751
[28]   High-Tc superconducting receiving coils for nuclear magnetic resonance imaging [J].
Lee, HL ;
Lin, IT ;
Chen, JH ;
Horng, HE ;
Yang, HC .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2005, 15 (02) :1326-1329
[29]   LARGE-AREA HIGH-QUALITY YBCO THIN-FILMS BY INVERTED CYLINDRICAL MAGNETRON TECHNIQUE [J].
LEMAITRE, Y ;
MERCANDALLI, LM ;
DESSERTENNE, B ;
MANSART, D ;
MARCILHAC, B ;
MAGE, JC .
PHYSICA C, 1994, 235 :643-644
[30]  
Miller DK, 1999, NES NUTR WS, V1, P79