Sutureless and reduced suture anastomosis of hollow vessels with fibrin glue: A review

被引:39
作者
Detweiler, MB
Detweiler, JG
Fenton, J
机构
[1] Univ Virginia, Sch Med Salem Roanoke, Vet Adm Med Ctr, Dept Psychiat Med, Salem, VA 24153 USA
[2] Virginia Polytech Inst & State Univ, Blacksburg, VA 24061 USA
[3] Crozer Chester Med Ctr, Dept Clin Chem, Upland, PA USA
[4] W Chester Univ, Dept Chem, W Chester, PA 19380 USA
关键词
autologus fibrin glue; common bile duct; esophagus; Fallopian tubes; fibrin glue; gastrointestinal tract; reduced suture anastomosis; sutureless anastomosis; trachea; ureter; vascular; vas deferens;
D O I
10.1080/089419399272377
中图分类号
R61 [外科手术学];
学科分类号
摘要
Research in reduced suture fibrin glue (FG) and sutureless FG anastomosis has been lagging behind FG utilization in other surgical fields. A review of the literature for vascular, esophageal, tracheal, gastrointestinal, common bile duct, ureteral, vas deferens, and Fallopian tube FG anastomosis indicates that reduced suture FG and sutureless FG procedures may be performed with less training, reduced operating time, leakage, ischemia, inflammation, and necrosis compared to sutured techniques. Reduced suture FG vasular anastomosis augments early anastomotic strength. Suture number for esophageal, tracheal, and tracheobronchial anastomoses can be reduced with FG, Bursting strength in pig small intestine and rat colon was lower at 4 days postoperatively, but returned to sutured strength at 7 days. Mortality was unaffected, and 18-month follow-up in sutureless FG intestinal anastomosis in pigs showed no stenosis. Preliminary ureteral studies have demonstrated successful sutureless FG and reduced suture FG laparoscopic techniques in pigs. Reduced suture FG and sutureless FG vas deferens anastomosis may reduce sperm granuloma rates, with increased patency and pregnancy rates. Patency and pregnancy rates have been similar for tubal FG, reduced suture FG, autologous fibrin glue (AFG), and sutured anastomosis. Any risk of viral transmission or immune response is eliminated by AFG. While there are few studies in many areas of FG hollow vessel anastomosis, the current literature illustrates many of the advantages of FG over other anastomotic techniques and should provide impetus for continued research in this promising field of surgery.
引用
收藏
页码:245 / 262
页数:18
相关论文
共 180 条
[21]  
CLARK DB, 1989, ANN CLIN LAB SCI, V19, P196
[22]   NON-SUTURE EXTERNAL CUFF TECHNIQUES FOR MICROVASCULAR ANASTOMOSIS [J].
COLEMAN, DJ ;
TIMMONS, MJ .
BRITISH JOURNAL OF PLASTIC SURGERY, 1989, 42 (05) :550-555
[23]  
COUTO J, 1987, SURGERY, V101, P354
[24]   Use of thrombin and fibrinogen in skin grafting - Preliminary report [J].
Cronkite, EP ;
Lozner, EL ;
Deaver, JM .
JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1944, 124 :976-978
[25]  
DARGENIO R, 1986, J REPROD MED, V31, P961
[26]   SCANNING ELECTRON-MICROSCOPY OF RABBIT TUBES AT DIFFERENT INTERVALS AFTER ANASTOMOSIS USING FIBRIN GLUE [J].
DARGENIO, R ;
RANELLETTI, FO ;
TANCREDI, G ;
RAGUSA, G ;
MAZZOCCO, A ;
GARCEA, N .
EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1988, 27 (02) :173-184
[27]   Gastrointestinal sutureless anastomosis using fibrin glue: Reinforcement of the sliding absorbable intraluminal nontoxic stent and development of a stent placement device [J].
Detweiler, MB ;
Verbo, A ;
Kobos, JW ;
Durastante, V ;
Pignoli, V ;
Granone, P ;
Magistrelli, P ;
Picciocchi, A .
JOURNAL OF INVESTIGATIVE SURGERY, 1996, 9 (02) :111-130
[28]   Sliding, absorbable, reinforced ring and an axially driven stent placement device for sutureless fibrin glue gastrointestinal anastomosis [J].
Detweiler, MB ;
Verbo, A ;
Kobos, JW ;
Granone, P ;
Picciocchi, A .
JOURNAL OF INVESTIGATIVE SURGERY, 1996, 9 (06) :495-504
[29]   Sutureless cholecystojejunostomy in pigs using an absorbable intraluminal stent and fibrin glue [J].
Detweiler, MB ;
Verbo, A ;
Marino, IR ;
Magistrelli, P ;
Picciocchi, A .
JOURNAL OF INVESTIGATIVE SURGERY, 1996, 9 (01) :13-26
[30]   SUTURELESS ANASTOMOSIS OF THE SMALL-INTESTINE AND THE COLON IN PIGS USING AN ABSORBABLE INTRALUMINAL STENT AND FIBRIN GLUE [J].
DETWEILER, MB ;
DURASTANTE, V ;
VERBO, A ;
MUTTILLO, I ;
PIANTELLI, M ;
KOBOS, JW ;
ANTINORI, A ;
GRANONE, P ;
MAGISTRELLI, P ;
PICCIOCCHI, A .
JOURNAL OF INVESTIGATIVE SURGERY, 1995, 8 (02) :129-140