Axial movement of the intravascular ultrasound probe during the cardiac cycle: Implications for three-dimensional reconstruction and measurements of coronary dimensions

被引:76
作者
Arbab-Zadeh, A
DeMaria, AN
Penny, WF
Russo, RJ
Kimura, BJ
Bhargava, V
机构
[1] Univ Calif San Diego, Med Ctr, Div Cardiovasc Med, San Diego, CA 92103 USA
[2] Vet Adm Med Ctr, San Diego, CA 92161 USA
[3] Scripps Clin & Res Fdn, La Jolla, CA 92037 USA
关键词
D O I
10.1016/S0002-8703(99)70011-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Motion of the intravascular ultrasound (IVUS) probe within the coronary artery from cardiac contraction may result in artifacts during 3-dimensional ultrasound image reconstruction and inaccurate measurements of coronary compliance. The purpose of this study was to establish whether longitudinal movement of the IVUS transducer in the coronary artery occurs and to quantify such motion. Methods In 31 patients we positioned IVUS transducers at 59 coronary branch points: 41 in the left anterior descending coronary artery, 11 in the left circumflex coronary artery, and 7 in the right coronary artery. In each image sequence the branching vessel oscillated in and out of the imaging plane during the cardiac cycle, confirming longitudinal transducer movement. The extent of movement was estimated by IVUS from the dimension of the branch vessel traversed. In addition, angiographic visualization and measurement of IVUS probe motion was performed at 17 branch points in 12 patients. Results Average longitudinal transducer movement as measured by IVUS was 1.50 +/- 0.80 mm (n = 46, range 0.5 to 5.5 mm). Because IVUS could not account for probe motion that exceeded the vessel branch diameter, the values obtained represent minimum movement. Average probe motion as assessed by cineangiography in a subset of 12 patients was 2.43 +/- 1.42 mm (range 0.57 to 6.56 mm). Conclusions This study establishes that longitudinal movement of IVUS transducers within coronary vessels occurs during the cardiac cycle. Because documented extent of motion may be sufficient to influence analysis, IVUS images are best obtained with electrocardiographic gating.
引用
收藏
页码:865 / 872
页数:8
相关论文
共 24 条
  • [1] DETERMINANTS OF CORONARY COMPLIANCE IN PATIENTS WITH CORONARY-ARTERY DISEASE - AN INTRAVASCULAR ULTRASOUND STUDY
    ALFONSO, F
    MACAYA, C
    GOICOLEA, J
    HERNANDEZ, R
    SEGOVIA, J
    ZAMORANO, J
    BANUELOS, C
    ZARCO, P
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (04) : 879 - 884
  • [2] BALLOON ANGIOPLASTY RESULTS IN INCREASED SEGMENTAL CORONARY DISTENSIBILITY - A LIKELY MECHANISM OF PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY
    BOTAS, J
    CLARK, DA
    PINTO, F
    CHENZBRAUN, A
    FISCHELL, TA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (05) : 1043 - 1052
  • [3] Bruining N, 1998, CATHETER CARDIO DIAG, V43, P254, DOI 10.1002/(SICI)1097-0304(199803)43:3<254::AID-CCD3>3.0.CO
  • [4] 2-8
  • [5] VOLUMETRIC INTRACORONARY ULTRASOUND - METHODS AND VALIDATION
    DHAWALE, PJ
    WILSON, DL
    HODGSON, JM
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1994, 33 (04): : 296 - 307
  • [6] Accurate three-dimensional reconstruction of intravascular ultrasound data - Spatially correct three-dimensional reconstructions
    Evans, JL
    Ng, KH
    Wiet, SG
    Vonesh, MJ
    Burns, WB
    Radvany, MG
    Kane, BJ
    Davidson, CJ
    Roth, SI
    Kramer, BL
    Meyers, SN
    McPherson, DD
    [J]. CIRCULATION, 1996, 93 (03) : 567 - 576
  • [7] INTRAVASCULAR ULTRASOUND IMAGING OF CORONARY-ARTERIES - IS 3 LAYERS THE NORM
    FITZGERALD, PJ
    STGOAR, FG
    CONNOLLY, AJ
    PINTO, FJ
    BILLINGHAM, ME
    POPP, RL
    YOCK, PG
    [J]. CIRCULATION, 1992, 86 (01) : 154 - 158
  • [8] 3D-SURFACE RECONSTRUCTION OF INTRAVASCULAR ULTRASOUND IMAGES USING PERSONAL-COMPUTER HARDWARE AND A MOTORIZED CATHETER CONTROL
    KLEIN, HM
    GUNTHER, RW
    VERLANDE, M
    SCHNEIDER, W
    VORWERK, D
    KELCH, J
    HAMM, M
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1992, 15 (02) : 97 - 101
  • [9] CORONARY-ARTERY LUMEN VOLUME MEASUREMENT USING 3-DIMENSIONAL INTRAVASCULAR ULTRASOUND - VALIDATION OF A NEW TECHNIQUE
    MATAR, FA
    MINTZ, GS
    DOUEK, P
    FARB, A
    VIRMANI, R
    JAVIER, SP
    POPMA, JJ
    PICHARD, AD
    KENT, KM
    SATLER, LF
    KELLER, M
    LEON, MB
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1994, 33 (03): : 214 - 220
  • [10] 3-DIMENSIONAL INTRAVASCULAR ULTRASONOGRAPHY - RECONSTRUCTION OF ENDOVASCULAR STENTS IN-VITRO AND IN-VIVO
    MINTZ, GS
    PICHARD, AD
    SATLER, LF
    POPMA, JJ
    KENT, KM
    LEON, MB
    [J]. JOURNAL OF CLINICAL ULTRASOUND, 1993, 21 (09) : 609 - 615