Evaluation and comparison of pulsed and continuous wave Radiofrequency electron paramagnetic resonance techniques for in vivo detection and imaging of free radicals

被引:53
作者
Yamada, KI [1 ]
Murugesan, R [1 ]
Devasahayam, N [1 ]
Cook, JA [1 ]
Mitchell, JB [1 ]
Subramanian, S [1 ]
Krishna, MC [1 ]
机构
[1] NCI, Radiat Biol Branch, Ctr Canc Res, NIH, Bethesda, MD 20892 USA
关键词
D O I
10.1006/jmre.2001.2487
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The performance of two electron paramagnetic resonance (EPR) spectrometers/imagers, one configured in pulsed mode and the other in continuous wave (CW) mode, at an operating frequency of 300 MHz is compared. Using the same resonator (except for altered Q-factors), identical samples and filling factors in the two techniques have been evaluated for their potentials and limitations for in vivo spectroscopic and imaging applications. The assessment is based on metrics such as sensitivity, spatial and temporal resolution, field of view, image artifacts, viable spin probes, and subjects of study. The spectrometer dead time limits the pulsed technique to samples with long phase memories (>275 ns). Nevertheless, for viable narrow-line spin probes, the pulsed technique offers better sensitivity and temporal resolution. The CW technique, on the other hand, does not restrict the choice at spin probes. In addition, the phase-sensitive narrow-band detection of the CW technique gives artifact-free images even for large objects. Selected examples illustrating the performance of the CW and pulsed techniques are presented to put the capabilities of the two techniques in perspective.
引用
收藏
页码:287 / 297
页数:11
相关论文
共 58 条
[11]  
Choi SM, 1997, INT J IMAG SYST TECH, V8, P263, DOI 10.1002/(SICI)1098-1098(1997)8:3<263::AID-IMA4>3.0.CO
[12]  
2-8
[13]   Three-dimensional pulsed ESR imaging [J].
Coy, A ;
Kaplan, N ;
Callaghan, PT .
JOURNAL OF MAGNETIC RESONANCE SERIES A, 1996, 121 (02) :201-205
[14]   HIGHLY SENSITIVE LOW-FREQUENCY SPECTROMETER FOR STUDY ON ELECTRON-SPIN RESONANCES [J].
DECORPS, M ;
FRIC, C .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1972, 5 (04) :337-&
[15]  
DEREK S, 1984, FOURIER TRANSFORM NM
[16]   Parallel coil resonators for time-domain radiofrequency electron paramagnetic resonance imaging of biological objects [J].
Devasahayam, N ;
Subramanian, S ;
Murugesan, R ;
Cook, JA ;
Afeworki, M ;
Tschudin, RG ;
Mitchell, JB ;
Krishna, MC .
JOURNAL OF MAGNETIC RESONANCE, 2000, 142 (01) :168-176
[17]   New experimental apparatus for multimodal resonance imaging: initial EPRI and NMRI experimental results [J].
Di Giuseppe, S ;
Placidi, G ;
Sotgiu, A .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (04) :1003-1016
[18]   A NEW 280-MHZ ESR SPECTROMETER [J].
DIJRET, D ;
BERANGER, M ;
BERNERD, A ;
JEANDEY, C ;
MOUSSAVI, M .
JOURNAL DE CHIMIE PHYSIQUE ET DE PHYSICO-CHIMIE BIOLOGIQUE, 1994, 91 (11-12) :1862-1867
[19]  
Ernst R. R., 1987, PRINCIPLES NUCL MAGN
[20]  
Ernst RR., 1970, J MAGN RESON, V3, P10