Hemodynamic exercise response in calves with an implantable biventricular centrifugal blood pump

被引:8
作者
Linneweber, J
Nonaka, K
Takano, T
Kawahito, S
Schulte-Eistrup, S
Motomura, T
Ichikawa, S
Mikami, M
Stevens, S
Schima, H
Wolner, E
Nosé, Y
机构
[1] Humboldt Univ, Univ Hosp Charite, Dept Cardiovasc Surg, D-10177 Berlin, Germany
[2] Baylor Coll Med, Michael E DeBakey Dept Surg, Houston, TX USA
[3] Univ Vienna, Dept Surg, Vienna, Austria
关键词
biventricular assist device; left ventricular assist device; right ventricular assist device;
D O I
10.1046/j.1525-1594.2001.06788.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An implantable biventricular assist device (BVAD) has been developed at Baylor College of Medicine using 2 centrifugal blood pumps. The aim of this study was to investigate the exercise-reflex response during non-pulsatile biventricular assistance and to evaluate to which degree the autoregulation of the system would accommodate the changed hemodynamic situation during physical exercise. The Baylor Gyro PI 710 BVAD has been implanted into 2 calves (strain half-Dexter) in a biventricular bypass fashion with native heart remaining. Allowing a 10 day convalescence, 2 animals were subjected to incremental exercise tests. The speed of the treadmill was increased at zero slope from 0.7 mph to 1.5 mph with increments of 0.2 mph every 3 min. During the exercise the pump flows were maintained at a fixed rate (6.93 +/- 0.01 L/min for the left ventricular assist device and 5.36 +/- 1.44 L/min for the right ventricular assist device). Hemodynamic parameters and pump performance were recorded continuously. The cardiac output (CO) and heart rate (HR) increased significantly during the exercise. CO increased from 11.1 +/- 0.3 to 13.1 +/- 0.4 L/min, and HR increased from 99 +/- 7.1 to 114 +/- 2.8 bpm, respectively. Mean aortic pressure, central venous pressure, and left arterial pressure did not change significantly. Also, no change was observed for the left and right pump flows. This totally implantable BVAD showed excellent long-term performance without any mechanical problems. It is feasible to operate without impairment under physical activity. However, the natural heart dominated the hemodynamic response during exercise under BVAD support. The left and the right pump flows did not increase spontaneously with exercise. We therefore conclude that a servo CO control system is necessary to regulate pump flows even during moderate exercise.
引用
收藏
页码:1018 / 1021
页数:4
相关论文
共 10 条
[1]   Rotary blood pump flow spontaneously increases during exercise under constant pump speed: Results of a chronic study [J].
Akimoto, T ;
Yamazaki, K ;
Litwak, P ;
Litwak, KN ;
Tagusari, O ;
Mori, T ;
Antaki, JF ;
Kameneva, MV ;
Watach, MJ ;
Umezu, M ;
Tomioka, J ;
Kormos, RL ;
Koyanagi, H ;
Griffith, BP .
ARTIFICIAL ORGANS, 1999, 23 (08) :797-801
[2]  
ARDELL JL, 1980, ARTERIAL BARORECEPTO, P311
[3]  
Freyschuss U, 1970, Acta Physiol Scand Suppl, V342, P1
[4]   BAROREFLEX PARTICIPATION IN REDISTRIBUTION OF CARDIAC-OUTPUT AT ONSET OF EXERCISE [J].
HALES, JRS ;
LUDBROOK, J .
JOURNAL OF APPLIED PHYSIOLOGY, 1988, 64 (02) :627-634
[5]   REFLEX CONTROL OF BLOOD-PRESSURE DURING EXERCISE [J].
LUDBROOK, J .
ANNUAL REVIEW OF PHYSIOLOGY, 1983, 45 :155-168
[6]   Development of a totally implantable biventricular bypass centrifugal blood pump system [J].
Nosé, Y ;
Nakata, K ;
Yoshikawa, M ;
Letsou, GV ;
Fujisawa, A ;
Wolner, E ;
Schima, H .
ANNALS OF THORACIC SURGERY, 1999, 68 (02) :775-779
[7]  
Rowell L.B., 1986, Human circulation: regulation during physical stress
[8]  
SHOOR PM, 1980, T AM SOC ART INT ORG, V26, P1
[9]   DO WE REALLY NEED PULSE - CHRONIC NONPULSATILE AND PULSATILE BLOOD-FLOW - FROM THE EXERCISE RESPONSE VIEWPOINTS [J].
YOZU, R ;
GOLDING, L ;
YADA, I ;
HARASAKI, H ;
TAKATANI, S ;
KAWADA, S ;
NOSE, Y .
ARTIFICIAL ORGANS, 1994, 18 (09) :638-642
[10]  
Yuhki A, 1999, ARTIF ORGANS, V23, P532