Cathodic detection of H2O2 using iodide-modified gold electrode in alkaline media

被引:85
作者
Miah, R
Ohsaka, T
机构
[1] Tokyo Inst Technol, Interdisciplinary Grad Sch Sci & Engn, Dept Elect Chem, Midori Ku, Yokohama, Kanagawa 2268502, Japan
[2] Shahjalal Univ Sci & Technol, Sch Phys Sci, Dept Chem, Sylhet 3114, Bangladesh
关键词
D O I
10.1021/ac0515935
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Oxidative chemisorption and cathodic stripping reductive desorption of iodide have been studied at a smooth polycrystalline gold (Au (poly)) electrode. Potential-dependent surface coverage of iodide has been controlled on the basis of its reductive desoprtion in 0.1 M KOH alkaline media and its quantitative oxidation to aqueous iodates in acidic media. The Au (poly) electrode surface catalyzes the decomposition of H2O2 to O-2. Specific adsorption of iodide on the Au electrode inhibits fully the catalytic decomposition and electrochemical oxidation of H2O2 as well as the adsorption of unknown impurities and the oxidative degradation of the electrode surface by H2O2. A quantitative characterization/detection of H2O2 at the iodide-modified Au (poly) electrode in the alkaline media has, thus, been achieved. Performance of the electrode toward the detection of H2O2 with respect to response time and sensitivity as well as operational stability has been evaluated. It has a sensitivity of 0.272 mA cm(-2) mM(-1) in amperometric measurements with a detection limit Of 1.0 X 10(-5) M H2O2, and the response time to achieve 95% of the steady-state current is < 20 s. The effect Of 02 in the air-saturated solution can be minimized by subtracting the additional current for the 02 reduction. Experimental measurements were based upon cyclic voltametric and amperometric techniques.
引用
收藏
页码:1200 / 1205
页数:6
相关论文
共 79 条
[71]   Structure of Br adlayers in the course of electrocatalytic reactions O2 reduction on Pt(111) and Au(100) [J].
Wang, JX ;
Marinkovic, NS ;
Adzic, RR .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 1998, 134 (1-2) :165-171
[72]   A novel hydrogen peroxide sensor based on horseradish peroxidase immobilized on colloidal Au modified ITO electrode [J].
Wang, L ;
Wang, EK .
ELECTROCHEMISTRY COMMUNICATIONS, 2004, 6 (02) :225-229
[73]   Hydrogen peroxide biosensor based on direct electrochemistry of hemoglobin immobilized on carbon paste electrode by a silica sol-gel film [J].
Wang, QL ;
Lu, GX ;
Yang, BJ .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 99 (01) :50-57
[74]   A NEW SURFACE PHASE IN LIQUID NORMAL-ALKANES [J].
WU, XZ ;
OCKO, BM ;
SIROTA, EB ;
SINHA, SK ;
DEUTSCH, M .
PHYSICA A, 1993, 200 (1-4) :751-758
[75]   A new film for the fabrication of an unmediated H2O2 biosensor [J].
Xu, Y ;
Peng, WL ;
Liu, XJ ;
Li, GX .
BIOSENSORS & BIOELECTRONICS, 2004, 20 (03) :533-537
[76]   INTERFACIAL STRUCTURE OF IODINE ELECTRODEPOSITED ON AU(111) - STUDIES BY LEED AND IN-SITU STM [J].
YAMADA, T ;
BATINA, N ;
ITAYA, K .
SURFACE SCIENCE, 1995, 335 (1-3) :204-209
[77]   STRUCTURE OF ELECTROCHEMICALLY DEPOSITED IODINE ADLAYER ON AU(111) STUDIED BY ULTRAHIGH-VACUUM INSTRUMENTATION AND IN-SITU STM [J].
YAMADA, T ;
BATINA, N ;
ITAYA, K .
JOURNAL OF PHYSICAL CHEMISTRY, 1995, 99 (21) :8817-8823
[78]  
ZHANG J, IN PRESS J ELECTRONA
[79]   Direct electron transfer of glucose oxidase molecules adsorbed onto carbon nanotube powder microelectrode [J].
Zhao, YD ;
Zhang, WD ;
Chen, H ;
Luo, QM .
ANALYTICAL SCIENCES, 2002, 18 (08) :939-941