Hydrogen peroxide biosensor based on direct electrochemistry of hemoglobin immobilized on carbon paste electrode by a silica sol-gel film

被引:83
作者
Wang, QL [1 ]
Lu, GX [1 ]
Yang, BJ [1 ]
机构
[1] Chinese Acad Sci, Lanzhou Inst Chem Phys, State Key Lab Oxo Synthesis & Select Oxidat, Lanzhou 730000, Peoples R China
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2004年 / 99卷 / 01期
关键词
hemoglobin; sol-gel film; direct chemistry; H2O2; biosensor;
D O I
10.1016/j.snb.2003.10.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Direct electrochemistry of hemoglobin (Hb) immobilized on carbon paste electrode (CPE) by a silica sol-gel film derived from tetraethylorthosilicate (TEOS) was investigated for the first time. Nevertheless, it still maintains its original structure after immobilization by sol-gel film. Hb/sol-gel modified electrode shows a thin layer electrochemistry behavior. The immobilized Hb displays the features of peroxidase and gives excellent performance in the electrocatalytic reduction of hydrogen peroxide (H2O2). Based which an unmediated biosensor for H2O2 was developed. H2O2 sensor exhibits a high sensitivity and a long-term stability. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:50 / 57
页数:8
相关论文
共 44 条
[1]   HETEROGENEOUS AND HOMOGENEOUS ELECTRON TRANSFERS TO AROMATIC HALIDES - ELECTROCHEMICAL REDOX CATALYSIS STUDY IN THE HALOBENZENE AND HALOPYRIDINE SERIES [J].
ANDRIEUX, CP ;
BLOCMAN, C ;
DUMASBOUCHIAT, JM ;
SAVEANT, JM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1979, 101 (13) :3431-3441
[2]  
BOND AM, 1980, MODERN POLAROGRAPHIC, P27
[3]   BIOCHEMICALLY ACTIVE SOL-GEL GLASSES - THE TRAPPING OF ENZYMES [J].
BRAUN, S ;
RAPPOPORT, S ;
ZUSMAN, R ;
AVNIR, D ;
OTTOLENGHI, M .
MATERIALS LETTERS, 1990, 10 (1-2) :1-5
[4]   Hydrogen peroxide biosensor based on sol-gel-derived glasses doped with Eastman AQ polymer [J].
Chen, X ;
Zhang, JZ ;
Wang, BQ ;
Cheng, GJ ;
Dong, SJ .
ANALYTICA CHIMICA ACTA, 2001, 434 (02) :255-260
[5]   An unmediated hydrogen peroxide biosensor based on hemoglobin incorporated in a montmorillonite membrane [J].
Fan, CH ;
Gao, QX ;
Zhu, DX ;
Wagner, G ;
Li, GX .
ANALYST, 2001, 126 (07) :1086-1089
[6]   Electron-transfer reactivity and enzymatic activity of hemoglobin in a SP sephadex membrane [J].
Fan, CH ;
Wang, HY ;
Sun, S ;
Zhu, DX ;
Wagner, G ;
Li, GX .
ANALYTICAL CHEMISTRY, 2001, 73 (13) :2850-2854
[7]   Mediatorless biosensor for H2O2 based on recombinant forms of horseradish peroxidase directly adsorbed on polycrystalline gold [J].
Ferapontova, EE ;
Grigorenko, VG ;
Egorov, AM ;
Börchers, T ;
Ruzgas, T ;
Gorton, L .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (03) :147-157
[8]   FLOW-THROUGH OPTICAL BIOSENSOR BASED ON THE PERMANENT IMMOBILIZATION OF AN ENZYME AND TRANSIENT RETENTION OF A REACTION-PRODUCT [J].
FERNANDEZROMERO, JM ;
DECASTRO, MDL .
ANALYTICAL CHEMISTRY, 1993, 65 (21) :3048-3052
[9]   Encapsulation of biologicals within silicate, siloxane, and hybrid sol-gel polymers: An efficient and generic approach [J].
Gill, I ;
Ballesteros, A .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1998, 120 (34) :8587-8598
[10]   Direct electron transfer and characterization of hemoglobin immobilized on a Au colloid-cysteamine-modified gold electrode [J].
Gu, HY ;
Yu, AM ;
Chen, HY .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 516 (1-2) :119-126