Evaluation of sample preparation techniques for mass measurements of PCR products using ESI-FT-ICR mass spectrometry

被引:24
作者
Null, AP
George, LT
Muddiman, DC
机构
[1] Virginia Commonwealth Univ, Dept Chem, Richmond, VA 23284 USA
[2] Virginia Commonwealth Univ, Med Coll Virginia, Massey Canc Ctr, Richmond, VA 23298 USA
关键词
D O I
10.1016/S1044-0305(02)00342-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Elimination of PCR buffer components and alkali metal cations (i.e., Na+, K+) is of critical importance to allow for accurate mass measurements of PCR products for genotyping and sequencing applications. Ethanol precipitation followed by microdialysis has been repeatedly shown to efficiently desalt PCR products for analysis by mass spectrometry and is considered the gold standard. Alternative cleanup techniques that are compatible with automation are explored here with the intent of expanding the bottleneck that exists between the production of PCR products and analysis by electrospray ionization mass spectrometry (ESI-MS). Numerous combinations of approaches were evaluated that included PCR purification kits and alcohol precipitations. The data shown here support alternative approaches to an ethanol precipitation followed by microdialysis that have comparable desalting efficiency and can be utilized for cleanup of PCR products generated from single reactions. (C) 2002 American Society for Mass Spectrometry.
引用
收藏
页码:338 / 344
页数:7
相关论文
共 44 条
[11]  
Hannis JC, 1998, RAPID COMMUN MASS SP, V12, P443, DOI 10.1002/(SICI)1097-0231(19980430)12:8<443::AID-RCM183>3.0.CO
[12]  
2-E
[13]  
Hannis JC, 1999, RAPID COMMUN MASS SP, V13, P954, DOI 10.1002/(SICI)1097-0231(19990530)13:10<954::AID-RCM593>3.0.CO
[14]  
2-R
[15]  
Hannis JC, 1999, RAPID COMMUN MASS SP, V13, P323, DOI 10.1002/(SICI)1097-0231(19990315)13:5<323::AID-RCM485>3.0.CO
[16]  
2-B
[17]   Detection of double-stranded PCR amplicons at the attomole level electrosprayed from low nanomolar solutions using FT-ICR mass spectrometry [J].
Hannis, JC ;
Muddiman, DC .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 369 (3-4) :246-251
[18]   Genotyping complex short tandem repeats using electrospray ionization Fourier transform ion cyclotron resonance multi-stage mass spectrometry [J].
Hannis, JC ;
Muddiman, DC ;
Null, AP .
ADVANCES IN NUCLEIC ACID AND PROTEIN ANALYSES, MANIPULATION, AND SEQUENCING, 2000, 1 :36-47
[19]   A dual electrospray ionization source combined with hexapole accumulation to achieve high mass accuracy of biopolymers in fourier transform ion cyclotron resonance mass spectrometry [J].
Hannis, JC ;
Muddiman, DC .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (10) :876-883
[20]   Electrospray quadrupole mass spectrometry analysis of model oligonucleotides and polymerase chain reaction products: Determination of base substitutions, nucleotide additions/deletions, and chemical modifications [J].
Krahmer, MT ;
Johnson, YA ;
Walters, J ;
Fox, KF ;
Fox, A ;
Nagpal, M .
ANALYTICAL CHEMISTRY, 1999, 71 (14) :2893-2900